{"product_id":"pmkhrmrly12s01-abb-infi-90-cable","title":"PMKHRMRLY12S01 ABB Infi 90 Cable","description":"\u003cp\u003eThe \u003cstrong\u003eABB PMKHRMRLY12S01\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003ePMKHRMRLY12S01\u003c\/strong\u003e Auxiliary Relay Block to DIO Cable, operates as a dedicated hardware component for interconnecting auxiliary relay blocks with digital input\/output termination units within Bailey Infi 90 and Net 90 systems.\u003c\/p\u003e\n\u003ch3\u003eTerminal Interface Configuration\u003c\/h3\u003e\n\u003cp\u003eThe PMKHRMRLY12S01 cable assembly features a dual-ended interface designed for industrial cabinet signal routing. The round leg section consists of a 12-core conductor array utilizing 0.75 mm2 (18 AWG) stranded copper wire, while the flat leg section transitions to a 12-way ribbon connector with a 1.27 mm pitch.\u003c\/p\u003e\n\u003ch3\u003eTechnical Performance Parameters\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePMKHRMRLY12S01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e10.2 x 5.1 x 10.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +80 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive component\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e300 V RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e6 A per conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRound Leg Specs\u003c\/td\u003e\n\u003ctd\u003e12-core, 0.75 mm2 (18 AWG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlat Leg Specs\u003c\/td\u003e\n\u003ctd\u003e12-way 1.27 mm pitch ribbon\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBending Radius\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;= 5 x OD (30 mm) fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInterconnect Bus Integration and I\/O Density\u003c\/h3\u003e\n\u003cp\u003eThe cable assembly enables discrete control signal transmission between relay termination blocks and Digital Input\/Output (DIO) modules without compromising backplane bus communication velocity. The 12-core wiring layout maintains consistent line impedance to support optimal I\/O density scaling while preserving hardware layer firmware flash compatibility across active Infi 90 cabinet racks.\u003c\/p\u003e\n\u003ch3\u003ePackage Scope\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x ABB PMKHRMRLY12S01 Auxiliary Relay Block to DIO Cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCable Routing and Termination Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMaintain a minimum fixed bending radius of 30 mm (\u0026gt;= 5 x outer diameter) along all cable conduit runs.\u003c\/li\u003e\n\u003cli\u003eAvoid tight cable ties or mechanical pinching across the 12-way flat ribbon section to prevent conductor insulation stress.\u003c\/li\u003e\n\u003cli\u003eEnsure power is disconnected from the target DIO module before seating or unseating the 1.27 mm connector.\u003c\/li\u003e\n\u003cli\u003eSeparate the 300 V RMS rated conductors from high-voltage AC motor power lines to prevent electromagnetic interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum voltage rating for the PMKHRMRLY12S01 conductors?\u003c\/p\u003e\n\u003cp\u003eThe cable assembly is insulation-rated for up to 300 V RMS at continuous operating temperatures up to 80 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum continuous current capacity per individual conductor?\u003c\/p\u003e\n\u003cp\u003eEach conductor in the 12-core assembly supports a continuous current rating of up to 6 A.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat are the physical specifications of the cable's round leg section?\u003c\/p\u003e\n\u003cp\u003eThe round leg comprises 12 individual copper cores with a cross-sectional conductor area of 0.75 mm2 (18 AWG).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat pitch standard is used on the flat ribbon connector interface?\u003c\/p\u003e\n\u003cp\u003eThe flat ribbon leg utilizes a standard 12-way connector configuration with a 1.27 mm pin pitch spacing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the absolute minimum bend radius allowed for fixed cable installation?\u003c\/p\u003e\n\u003cp\u003eThe cable requires a minimum fixed bend radius equal to or greater than 5 times the outer diameter (30 mm).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the operating temperature threshold for industrial panel environments?\u003c\/p\u003e\n\u003cp\u003eThe assembly operates reliably within ambient temperature limits ranging from -40 to +80 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the PMKHRMRLY12S01 draw internal electrical power from the bus?\u003c\/p\u003e\n\u003cp\u003eNo, the cable is a passive physical inter-module connectivity link and consumes no active power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhich control system series utilize this relay block interface cable?\u003c\/p\u003e\n\u003cp\u003eThe cable connects auxiliary relay blocks to digital I\/O units across Bailey Infi 90 and Net 90 systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021111218349,"sku":"PMKHRMRLY12S01","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/PMKHRMRLY12S01.jpg?v=1789278835","url":"https:\/\/www.maxwellplc.com\/products\/pmkhrmrly12s01-abb-infi-90-cable","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}