{"product_id":"pm864-3bse018151r1-abb-ac-800m-processor-unit","title":"PM864 3BSE018151R1 ABB AC 800M Processor Unit","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB PM864 3BSE018151R1\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePM864\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProcessor Unit, operates as a dedicated hardware component for high-speed logic execution and network coordination within ABB AC 800M control platforms.\u003c\/p\u003e\n\u003ch3\u003eModel Matrix Configuration\u003c\/h3\u003e\n\u003cp\u003eThe PM864 3BSE018151R1 is a high-performance CPU module equipped with a dual-core 1.2 GHz processor. The base model number identifies the hardware architecture, while the 3BSE018151R1 part number confirms the standard production revision for AC 800M system compatibility. No field-selectable hardware options exist; functional capability is determined by firmware load and system configuration.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePM864 3BSE018151R1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSweden\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e19 x 13.8 x 13.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 deg C to +60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15 W typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProcessor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual-core 1.2 GHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFlash Memory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 GB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eControl Platform Integration\u003c\/h3\u003e\n\u003cp\u003eThe module is engineered to support backplane bus communication velocity sufficient for demanding real-time control loops. It maintains firmware flash compatibility, allowing updates via the system controller. The hardware supports deterministic network communication through dual 10\/100\/1000 Mbps Ethernet ports, ensuring synchronization within Profinet or related Ethernet-based topologies. Users must adhere to I\/O density scaling limits defined by the AC 800M controller load profiles to maintain cycle-time stability.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePM864 3BSE018151R1 Processor Unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTechnical integration documentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eESD-compliant protective packaging\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Secure the module chassis to the rack grounding bus to ensure electromagnetic interference immunity and backplane signal integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMounting: Insert the unit into the assigned controller slot and confirm the locking mechanism is engaged to prevent vibration-induced disconnection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCommunication: Utilize shielded Cat6 Ethernet cables for the dual 10\/100\/1000 Mbps ports to ensure data integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThermal: Maintain unobstructed airflow around the module vents; do not mount directly above heat-dissipating components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInspection: Verify module status via the front-panel indicator array prior to initializing system logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is this processor hot-swappable?\u003c\/p\u003e\n\u003cp\u003eA: No. Power must be isolated from the AC 800M controller rack backplane before inserting or removing the PM864 module to prevent damage to the connector pins.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How does the dual Ethernet port redundancy function?\u003c\/p\u003e\n\u003cp\u003eA: The ports support redundant network topologies, allowing the controller to maintain communication even if one network path fails.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the 4 GB flash storage user-accessible?\u003c\/p\u003e\n\u003cp\u003eA: The storage is managed by the system controller for firmware, configuration files, and log data; it is not intended for general-purpose user file storage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What indicates that the dual-core processor is overloaded?\u003c\/p\u003e\n\u003cp\u003eA: Excessive CPU load is reported through the system diagnostics software, showing high task execution times and potential scan cycle violations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can I use this in an existing AC 800M rack?\u003c\/p\u003e\n\u003cp\u003eA: Yes, it is forward-compatible with standard AC 800M hardware, provided the backplane and firmware versions are within supported limits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How are internal faults diagnosed?\u003c\/p\u003e\n\u003cp\u003eA: Faults are logged in the controller diagnostic buffer and accessible via the engineering workstation or connected Ethernet diagnostic tools.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the module require periodic battery replacement?\u003c\/p\u003e\n\u003cp\u003eA: No. The internal state and clock retention are managed through solid-state memory, eliminating the need for periodic battery maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the impact of exceeding the +60 deg C limit?\u003c\/p\u003e\n\u003cp\u003eA: Exceeding operating temperatures causes thermal throttling of the CPU and potential permanent degradation of the internal flash memory cells.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45231177662637,"sku":"3BSE018151R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb-pm864-3bse018151r1-processor-unit-orx1slxk1w2_548f69b1-aa2f-4386-9bb2-55a527c29f9e.jpg?v=1762942313","url":"https:\/\/www.maxwellplc.com\/products\/pm864-3bse018151r1-abb-ac-800m-processor-unit","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}