{"product_id":"phbain2000s100-abb-analog-input-base-infi-90-harmony-block-i-o","title":"PHBAIN2000S100 ABB Analog Input Base Infi 90 \/ Harmony Block I\/O","description":"\u003cp\u003eThe \u003cstrong\u003eABB PHBAIN2000S100\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eAIN 200\u003c\/strong\u003e Analog Input Base, operates as a dedicated hardware component for 8-channel analog signal acquisition within Infi 90 and Harmony Block I\/O networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Revision and Variant Structure\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePHBAIN2000S100\u003c\/strong\u003e: Primary revision terminal base supporting up to 8 analog input loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePHBAIN2000S200\u003c\/strong\u003e: Secondary hardware variant with modified backplane routing paths.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAIN 200 Base Standard\u003c\/strong\u003e: Generic spare hardware designation for field terminal interface units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eParametric Technical Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePHBAIN2000S100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpare Model\u003c\/td\u003e\n\u003ctd\u003eAIN 200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSWEDEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e20.3 x 27.9 x 17.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 ... +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 ... +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 - 95 % RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive base unit (N\/A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e8 analogue input loops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e300 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent \/ Terminal\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Isolation\u003c\/td\u003e\n\u003ctd\u003e2.3 kV AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 3 mOhm initial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHarmonized Tariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Backplane Bus Integration\u003c\/h3\u003e\n\u003cp\u003eThe PHBAIN2000S100 maintains fast backplane bus communication velocity across connected Harmony Block I\/O nodes. Incorporating 2.3 kV AC dielectric isolation protects internal processing logic against common-mode noise on the 8 analogue input loops. Low contact resistance (\u0026lt;= 3 mOhm) minimizes voltage drop variances across screw terminal contact surfaces, sustaining precise analog measurement data transmission to active DCS controllers.\u003c\/p\u003e\n\u003ch3\u003eDelivery Package Scope\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x ABB PHBAIN2000S100 Analog Input Base Assembly\u003c\/li\u003e\n\u003cli\u003e1 x Terminal Connector Block Kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWiring Strategy and Cabinet Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Screw Tightening\u003c\/strong\u003e: Fasten field terminal screws to a maximum torque of 0.6 Nm to prevent frame strip damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Shield Grounding\u003c\/strong\u003e: Ground instrument cable shields at the base frame grounding lug to maintain noise suppression across input channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Separation\u003c\/strong\u003e: Route low-level analog input cables in dedicated wiring raceways separate from AC power conduits by at least 300 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDielectric Safety Clearance\u003c\/strong\u003e: Ensure field wiring insulation maintains at least 300 V AC continuous rating specs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat causes channel measurement drift on the PHBAIN2000S100 analog input base?\u003c\/p\u003e\n\u003cp\u003eOxidation or loose wire connections causing initial contact resistance to exceed 3 mOhm will introduce voltage drop errors across the input loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the AIN 200 base handle voltage spikes on the input signal lines?\u003c\/p\u003e\n\u003cp\u003eYes, the terminal base architecture features 2.3 kV AC dielectric isolation, protecting backplane logic against high-voltage transient spikes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs hot-swapping allowed for input processing modules on this mounting base?\u003c\/p\u003e\n\u003cp\u003eModules can be hot-swapped if system firmware supports hot insertion, provided field input power loops are temporarily suppressed or fused.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat current limit applies to individual terminal screws on the base block?\u003c\/p\u003e\n\u003cp\u003eEach physical terminal point on the PHBAIN2000S100 base is rated to continuously withstand up to 10 A without thermal breakdown.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does high humidity affect signal isolation across adjacent channels?\u003c\/p\u003e\n\u003cp\u003eOperating above 95% non-condensing humidity degrades tracking resistance across the terminal board, increasing channel-to-channel crosstalk.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the PHBAIN2000S100 base draw operational current directly from the backplane?\u003c\/p\u003e\n\u003cp\u003eNo, the unit functions as a passive physical terminal interface with negligible power consumption on the communication backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAre all 8 analog input channels galvanically isolated from each other on the base?\u003c\/p\u003e\n\u003cp\u003eThe channels share a common base ground scheme; primary isolation of 2.3 kV AC is provided between the field wiring and the backplane logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat wire size range is supported by the screw terminal blocks?\u003c\/p\u003e\n\u003cp\u003eThe terminal assemblies accommodate field wiring sizes ranging from 12 AWG down to 22 AWG solid or stranded copper conductors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021109645485,"sku":"PHBAIN2000S100","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/PHBAIN2000S100_1.jpg?v=1789279146","url":"https:\/\/www.maxwellplc.com\/products\/phbain2000s100-abb-analog-input-base-infi-90-harmony-block-i-o","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}