{"product_id":"pepperl-fuchs-z728-z-system-zener-barrier-2-channel-28v-300-ohm","title":"Pepperl+Fuchs Z728 Z-System Zener Barrier 2-Channel 28V 300 Ohm","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Pepperl+Fuchs Z728 serves as a fundamental protective component within the Z-System, providing cost-effective intrinsic safety for electrical circuits in hazardous areas. This dual-channel Zener barrier limits the energy transferred from the safe area to the explosive atmosphere, preventing sparks or thermal effects from causing ignition. By utilizing high-quality shunt zeners, resistors, and fuses, the Z728 safeguards instrumentation loops such as solenoid valves, transmitters, and proximity sensors. This module proves indispensable in oil refineries, gas processing plants, and chemical storage facilities where preventing electrical faults from entering Zone 0 or Zone 1 is a critical safety mandate. Its compact, DIN-rail mountable design allows for high-density installation within control cabinets while maintaining the rigid safety integrity required for hazardous operations.\u003c\/p\u003e\n\u003ch2\u003eCore Technical Advantages\u003c\/h2\u003e\n\u003cp\u003eThis Zener barrier utilizes a DC-version hardware architecture, specifically designed for positive polarity loops where the safe-area voltage remains referenced to ground. The Z728 incorporates a 28V working voltage limit and a 300 Ohm internal resistor to precisely control current flow into the hazardous zone. The dual-channel configuration enables the protection of two independent signal lines or a single balanced loop within one 12.5mm housing, maximizing cabinet space efficiency. Unlike isolated barriers, the Z728 relies on a high-integrity ground connection to shunt excess energy safely, ensuring that any fault voltage remains clamped below the ignition threshold of volatile gases. The robust internal fuse protects the zener diodes from prolonged overvoltage conditions, ensuring the device remains a reliable \"last line of defense\" in your safety architecture.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2-Channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWorking Voltage (Uw)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMax. 26.9 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eZener Voltage (Uz)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e28 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries Resistance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMin. 301 Ohm \/ Max. 327 Ohm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFuse Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePolarity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePositive (DC version)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eScrew Terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35mm DIN Rail\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 °C to 60 °C (-4 °F to 140 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12.5mm (W) x 115mm (H) x 110mm (D)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eApproximate Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e150 g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eInstallation Guide\u003c\/h2\u003e\n\u003cp\u003eEngineers must mount the Z728 on a standard 35mm DIN rail that is directly bonded to a high-integrity Intrinsic Safety (IS) Earth ground. The resistance between the barrier's ground terminal and the main plant earth must remain below 1 Ohm to guarantee effective energy shunting during a fault. When wiring, ensure that hazardous area cables remain physically separated from safe-area cables by at least 50mm to prevent inductive or capacitive coupling. Technical staff should verify that the supply voltage does not exceed the 26.9V working voltage (Uw) during normal operation, as exceeding this limit will cause leakage current through the zeners and may eventually blow the internal fuse. For maintenance, always test the continuity of the fuse via the designated terminals if the loop signal is lost.\u003c\/p\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eThe Z728 offers a streamlined engineering advantage for projects where budget-conscious safety is a priority without sacrificing Pepperl+Fuchs reliability. Its passive design requires no external power supply, simplifying the electrical distribution within the cabinet and reducing heat generation. The Z728 integrates seamlessly with a wide range of DC-powered field devices, offering universal compatibility for digital or analog loops that share a common ground. This reliability in extreme environments ensures that your safety loops remain active for decades, providing a durable barrier against transients and catastrophic electrical failures in high-risk processing zones.\u003c\/p\u003e\n\u003ch2\u003eDelivery \u0026amp; Logistics\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDelivery Time:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3-5 days once payment is finalized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShipping Carriers:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eShipped globally via DHL, FEDEX, or UPS. Every unit is dispatched in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eanti-static packaging\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewithin its original factory-sealed box to guarantee performance upon arrival.\u003c\/p\u003e\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003eQ1: What is the difference between the Z728 and an isolated barrier like the KFD2-STC5-1?\u003c\/p\u003e\n\u003cp\u003eA1: The Z728 is a passive Zener barrier that requires a high-quality ground (IS Earth) to function. An isolated barrier uses galvanic isolation and does not require an IS Earth ground, making it more suitable for systems with ground loop interference.\u003c\/p\u003e\n\u003cp\u003eQ2: Can I use the Z728 for AC signals?\u003c\/p\u003e\n\u003cp\u003eA2: No. The Z728 is a DC-version barrier with positive polarity. For AC signals or bipolar signals, you must select an AC-version barrier (usually designated with \"AC\" or a different model series) that can handle voltage swings above and below ground.\u003c\/p\u003e\n\u003cp\u003eQ3: What happens if the internal fuse blows?\u003c\/p\u003e\n\u003cp\u003eA3: If the internal fuse blows due to a surge or overvoltage, the barrier must be replaced. The fuse is encapsulated within the unit to prevent tampering and ensure that the safety parameters of the barrier are never compromised.\u003c\/p\u003e\n\u003cp\u003eQ4: Why is the grounding so critical for the Z728?\u003c\/p\u003e\n\u003cp\u003eA4: Because the Z728 \"shunts\" excess energy to ground during a fault, the ground path is the only thing preventing that energy from reaching the hazardous area. A poor ground connection would allow the voltage in the hazardous area to rise to dangerous, ignitable levels.\u003c\/p\u003e","brand":"Pepperl + Fuchs","offers":[{"title":"Default Title","offer_id":45952924647597,"sku":"Z728","price":15.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/Z728_1.jpg?v=1777274936","url":"https:\/\/www.maxwellplc.com\/products\/pepperl-fuchs-z728-z-system-zener-barrier-2-channel-28v-300-ohm","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}