{"product_id":"pepperl-fuchs-pmp-pz1-c-11-control-units-ex-e-panel-mount-pmp-series","title":"Pepperl+Fuchs PMP.PZ1.C.11 Control Units Ex e, Panel Mount PMP Series","description":"\u003cp data-path-to-node=\"4\"\u003e\u003cspan\u003eConfigured for hazardous-area operator control and local panel integration in industrial automation networks,\u003c\/span\u003e\u003cspan\u003e the \u003c\/span\u003e\u003cb data-path-to-node=\"4\" data-index-in-node=\"114\"\u003ePepperl+Fuchs PMP.PZ1.C.11\u003c\/b\u003e\u003cspan\u003e (\u003c\/span\u003e\u003cb data-path-to-node=\"4\" data-index-in-node=\"142\"\u003ePMP.PZ1.C.11\u003c\/b\u003e\u003cspan\u003e Control Units Ex e,\u003c\/span\u003e\u003cspan\u003e Panel Mount) provides direct physical\/electrical execution.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"5\"\u003ePart Number Breakdown and Configuration Matrix\u003c\/h3\u003e\n\u003cp data-path-to-node=\"6\"\u003e\u003cspan\u003eThe complete ordering code designates the PMP product family,\u003c\/span\u003e\u003cspan\u003e the PZ1 enclosure or operator element variant,\u003c\/span\u003e\u003cspan\u003e the specific contact block and actuator configuration denoted by code C,\u003c\/span\u003e\u003cspan\u003e and the terminal or mounting revision designated by suffix 11 for hazardous-area panel installations.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"7\"\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"8\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,1,0,0\"\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,1,1,0\"\u003ePMP.PZ1.C.11\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,2,0,0\"\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,2,1,0\"\u003ePepperl+Fuchs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,3,0,0\"\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,3,1,0\"\u003eControl Unit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,4,0,0\"\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,4,1,0\"\u003ePMP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,5,0,0\"\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,5,1,0\"\u003eGermany\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,6,0,0\"\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,6,1,0\"\u003eApprox. 350 g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,7,0,0\"\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,7,1,0\"\u003e15.0 cm x 12.0 cm x 8.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,8,0,0\"\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,8,1,0\"\u003e-20 to 60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,9,0,0\"\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,9,1,0\"\u003eNot applicable (passive electromechanical element)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,10,0,0\"\u003eContact Configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,10,1,0\"\u003e1 NC \/ 1 NO slow-action contacts\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,11,0,0\"\u003eRated Operational Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,11,1,0\"\u003eMax. 250 VAC \/ VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,12,0,0\"\u003eRated Operational Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,12,1,0\"\u003eMax. 16 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,13,0,0\"\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,13,1,0\"\u003ePanel mount (Increased Safety Ex e)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,14,0,0\"\u003eProtection Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,14,1,0\"\u003eIP66\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-path-to-node=\"9\"\u003eSurge Voltage Protection Limits and Intrinsic Safety Compliance\u003c\/h3\u003e\n\u003cp data-path-to-node=\"10\"\u003e\u003cspan\u003eEngineered for Pepperl+Fuchs hazardous-area infrastructure,\u003c\/span\u003e\u003cspan\u003e this control unit incorporates robust mechanical enclosures and increased safety (Ex e) terminal designs to prevent sparking within explosive atmospheres.\u003c\/span\u003e\u003cspan\u003e Integrated surge voltage protection limits safeguard connected switching circuits against transient switching spikes.\u003c\/span\u003e\u003cspan\u003e The high-integrity contact blocks ensure reliable low-voltage signal transmission while maintaining strict electrical clearance and creepage distances in demanding industrial environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"11\"\u003eOrdering Information and Package Contents\u003c\/h3\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cspan\u003e1 x Pepperl+Fuchs PMP.\u003c\/span\u003e\u003cspan\u003ePZ1.\u003c\/span\u003e\u003cspan\u003eC.\u003c\/span\u003e\u003cspan\u003e11 Control Unit Ex e,\u003c\/span\u003e\u003cspan\u003e Panel Mount assembly\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cspan\u003e1 x Integrated contact block set (1 NC \/ 1 NO)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cspan\u003e1 x Panel mounting lock nut and sealing gasket ring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,3,0\"\u003e\u003cspan\u003e1 x Technical documentation and safety compliance sheet\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"13\"\u003eField Installation Guidelines and Mounting Practices\u003c\/h3\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cspan\u003eCut the mounting aperture into the control panel wall according to the specified diameter dimensions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cspan\u003eInsert the actuator assembly through the front panel opening,\u003c\/span\u003e\u003cspan\u003e ensuring the sealing gasket is correctly positioned against the enclosure face.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,2,0\"\u003e\u003cspan\u003eSecure the unit from the rear using the mounting lock nut,\u003c\/span\u003e\u003cspan\u003e applying recommended torque to maintain the IP66 seal rating.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,3,0\"\u003e\u003cspan\u003eConnect field wiring to the increased safety (Ex e) screw terminals,\u003c\/span\u003e\u003cspan\u003e ensuring proper conductor stripping length.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,4,0\"\u003e\u003cspan\u003eVerify ground continuity across the metallic panel structure before energizing the control circuit.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"15\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul data-path-to-node=\"16\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,0,0\"\u003e\u003cspan\u003eQ:\u003c\/span\u003e\u003cspan\u003e What is the primary function of the Pepperl+Fuchs PMP.\u003c\/span\u003e\u003cspan\u003ePZ1.\u003c\/span\u003e\u003cspan\u003eC.\u003c\/span\u003e\u003cspan\u003e11?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,0,1\"\u003e\u003cspan\u003eA:\u003c\/span\u003e\u003cspan\u003e It serves as a hazardous-area control unit providing operator interface and electrical switching inside Ex e panels.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,1,0\"\u003e\u003cspan\u003eQ:\u003c\/span\u003e\u003cspan\u003e What type of contact elements are integrated into this control unit?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,1,1\"\u003e\u003cspan\u003eA:\u003c\/span\u003e\u003cspan\u003e The unit features integrated slow-action contact blocks comprising one normally closed (NC) and one normally open (NO) contact.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,2,0\"\u003e\u003cspan\u003eQ:\u003c\/span\u003e\u003cspan\u003e What hazardous area protection method is utilized by this device?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,2,1\"\u003e\u003cspan\u003eA:\u003c\/span\u003e\u003cspan\u003e It is certified for Increased Safety (Ex e) applications allowing panel-mounted installation in explosive atmospheres.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,3,0\"\u003e\u003cspan\u003eQ:\u003c\/span\u003e\u003cspan\u003e What is the maximum operational voltage rating for the contacts?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,3,1\"\u003e\u003cspan\u003eA:\u003c\/span\u003e\u003cspan\u003e The internal switching contacts support up to 250 VAC or VDC under rated operational conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,4,0\"\u003e\u003cspan\u003eQ:\u003c\/span\u003e\u003cspan\u003e What is the maximum continuous current capacity of the switch contacts?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,4,1\"\u003e\u003cspan\u003eA:\u003c\/span\u003e\u003cspan\u003e The unit is rated for a maximum operational current of 16 A.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,5,0\"\u003e\u003cspan\u003eQ:\u003c\/span\u003e\u003cspan\u003e What degree of environmental protection does the front enclosure provide?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,5,1\"\u003e\u003cspan\u003eA:\u003c\/span\u003e\u003cspan\u003e When correctly mounted with its gasket,\u003c\/span\u003e\u003cspan\u003e the assembly achieves an IP66 protection rating against dust and water ingress.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,6,0\"\u003e\u003cspan\u003eQ:\u003c\/span\u003e\u003cspan\u003e How is the control unit secured to the industrial control panel?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,6,1\"\u003e\u003cspan\u003eA:\u003c\/span\u003e\u003cspan\u003e It mounts through a standard circular panel cutout and is fastened securely from the rear using a threaded locking ring.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,7,0\"\u003e\u003cspan\u003eQ:\u003c\/span\u003e\u003cspan\u003e Can the contact blocks be wired while the control panel is energized?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,7,1\"\u003e\u003cspan\u003eA:\u003c\/span\u003e\u003cspan\u003e All wiring operations must be performed in a de-energized state in accordance with local electrical safety regulations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":47508773077165,"sku":"PMP.PZ1.C.11","price":343.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/pmp.pz1.c.11.jpg?v=1792984912","url":"https:\/\/www.maxwellplc.com\/products\/pepperl-fuchs-pmp-pz1-c-11-control-units-ex-e-panel-mount-pmp-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}