{"product_id":"panasonic-dp-101-e-p-dual-display-digital-pressure-sensor-high-pressure-type","title":"Panasonic DP-101-E-P Dual Display Digital Pressure Sensor High-Pressure Type","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Panasonic DP-101-E-P sets the industrial standard for high-precision gas pressure monitoring, featuring a unique dual-display architecture that provides simultaneous visualization of current values and threshold setpoints. This high-pressure type sensor operates across a versatile range of -100.0 to +100.0 kPa, making it an essential component for monitoring vacuum suction, positive pressure in pneumatic lines, and leak detection in automated assembly cells. The high-resolution digital interface eliminates the ambiguity of analog gauges, offering sub-millimeter accuracy in pressure detection. Designed for integration into fast-paced semiconductor and electronic packaging lines, the DP-101-E-P utilizes a specialized sensing element that delivers superior repeatability. Its compact, lightweight housing allows for high-density manifold mounting, providing engineers with a high-authority diagnostic tool to ensure the operational integrity of critical pneumatic systems and gas-dependent industrial processes.\u003c\/p\u003e\n\u003ch2\u003eCore Technical Advantages\u003c\/h2\u003e\n\u003ch3\u003eDual 3-Color Digital Display\u003c\/h3\u003e\n\u003cp\u003eThe hardware incorporates a primary display for the current pressure and a secondary display for the threshold value. This dual-visualization allows operators to verify system status at a glance without switching menu modes. The 3-color display (Red, Green, Orange) provides immediate visual feedback; for instance, the screen can turn Red during an overpressure event or Green during normal operation, significantly reducing human error in busy factory environments.\u003c\/p\u003e\n\u003ch3\u003eAdvanced Copy Functionality\u003c\/h3\u003e\n\u003cp\u003eThe DP-101-E-P includes a master-to-slave copy function. When installing multiple sensors on a single production line, engineers can program one unit and export the settings to all other sensors via the signal wiring. This hardware-level efficiency slashes commissioning time and ensures absolute uniformity in threshold settings across the entire pneumatic network.\u003c\/p\u003e\n\u003ch3\u003eEnhanced PNP Output Logic\u003c\/h3\u003e\n\u003cp\u003eThe \"P\" suffix designates a PNP open-collector output, specifically tailored for European and global industrial safety standards. The sensor provides two independent outputs, allowing for complex control logic such as window comparator mode or hysteresis mode. This flexibility enables the sensor to manage both the \"Ready\" signal and the \"Emergency Stop\" signal from a single pressure port.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMetric Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePressure Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-100.0 to +100.0 kPa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFluid Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAir \/ Non-corrosive Gases\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 to 24 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePNP Open Collector (Dual Output)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRepeatability\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWithin ±0.2% F.S.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.5 ms or less\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP40\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWidth (W)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e30 mm\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHeight (H)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e30 mm\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDepth (D)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e42.5 mm\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eApproximate Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e0.04 kg\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eEngineering Installation Guide\u003c\/h2\u003e\n\u003ch3\u003ePneumatic Port Integration\u003c\/h3\u003e\n\u003cp\u003eThe DP-101-E-P features a standard M5 female thread and an R 1\/8 male thread. When mounting to a manifold, apply a suitable thread sealant or O-ring to ensure a leak-proof seal. Avoid over-torquing the fitting beyond\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e7 Nm\u003c\/strong\u003e, as excessive force can distort the internal silicon sensing diaphragm and lead to a permanent zero-point shift.\u003c\/p\u003e\n\u003ch3\u003eElectrical Interference Management\u003c\/h3\u003e\n\u003cp\u003eRoute the sensor cable away from high-voltage AC motor leads and inverter power cables. While the DP-101-E-P contains internal surge protection, high-frequency noise from nearby VFDs can cause \"ghost\" fluctuations in the digital display. Use shielded cables if the sensor is located within\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100 mm\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof heavy switching gear to maintain signal purity.\u003c\/p\u003e\n\u003ch3\u003eZero-Point Adjustment\u003c\/h3\u003e\n\u003cp\u003ePerform the \"Zero-adjustment\" procedure at atmospheric pressure before final commissioning. This calibrates the sensor to the local ambient environment, ensuring the -100 to +100 kPa range remains centered. Regularly check the air filter upstream of the sensor; oil mist or moisture accumulation in the pressure port will degrade accuracy and eventually damage the sensing element.\u003c\/p\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eThe DP-101-E-P excels in high-speed pick-and-place applications where milliseconds determine total cycle efficiency. Its 2.5 ms response time ensures that vacuum-loss detection happens instantaneously, preventing product drops and minimizing scrap rates. The robust hardware architecture survives millions of pressure cycles without drift, providing a long-term, maintenance-free solution for OEM machine builders. By standardizing on the DP-100 series, facilities benefit from a compact 30mm footprint that fits into the tightest cabinet spaces while offering the data depth of a much larger industrial transmitter. The non-contact sensing principle eliminates mechanical wear, providing a high-precision monitoring solution that remains stable even under constant vibration and rapid pressure cycling in Tier-1 automotive and electronic assembly plants.\u003c\/p\u003e\n\u003ch2\u003eDelivery \u0026amp; Logistics\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDelivery time:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3-5 days when payment finish.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShipping Carriers:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBY DHL\/FEDEX\/UPS.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWe utilize\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emoisture-barrier anti-static bags\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand reinforced, shock-resistant padding. Every DP-101-E-P unit is shipped in its original factory-sealed box to guarantee the precision display and sensitive pressure port arrive in flawless condition.\u003c\/p\u003e\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003eQ1: What is the specific meaning of the \"E\" in the model number?\u003c\/p\u003e\n\u003cp\u003eA1: The \"E\" suffix designates the low-pressure\/vacuum refined version of the DP-100 series, specifically optimized for the -100 to +100 kPa range with the M5\/R1\/8 pressure port configuration.\u003c\/p\u003e\n\u003cp\u003eQ2: Can I use this sensor to monitor water or oil pressure?\u003c\/p\u003e\n\u003cp\u003eA2: No, the DP-101-E-P is strictly for use with air and non-corrosive gases. Liquid ingress will destroy the internal sensing element. For liquid applications, please consult us for our stainless-steel diaphragm series.\u003c\/p\u003e\n\u003cp\u003eQ3: How does the Copy Function work?\u003c\/p\u003e\n\u003cp\u003eA3: By connecting the \"Copy\" wire of the master sensor to the input of the slave sensors, you can mirror all threshold values, hysteresis settings, and display configurations instantly, ensuring 100% consistency across your production line.\u003c\/p\u003e\n\u003cp\u003eQ4: What is the benefit of the dual display during maintenance?\u003c\/p\u003e\n\u003cp\u003eA4: During troubleshooting, a technician can see the \"Live\" pressure on the top screen and the \"Target\" pressure on the bottom screen simultaneously. This makes it immediately obvious if a pump is failing or if a setpoint has been incorrectly adjusted without needing to navigate through software menus.\u003c\/p\u003e","brand":"Panasonic","offers":[{"title":"Default Title","offer_id":45958829899949,"sku":"DP-101-E-P","price":69.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/DP-101-E-P_1.jpg?v=1777427552","url":"https:\/\/www.maxwellplc.com\/products\/panasonic-dp-101-e-p-dual-display-digital-pressure-sensor-high-pressure-type","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}