{"product_id":"p-hb-rmu-8000n200-abb-bailey-infi-90-terminal-base-repeater","title":"P-HB-RMU-8000N200 ABB Bailey Infi 90 Terminal Base Repeater","description":"\u003cp\u003eThe \u003cb\u003eABB P-HB-RMU-8000N200\u003c\/b\u003e, also cataloged as the \u003cb\u003eP-HB-RMU-8000N200\u003c\/b\u003e Terminal Base Repeater, operates as a dedicated hardware component for signal amplification and bus extension within Bailey Infi 90 and Harmony I\/O systems.\u003c\/p\u003e\n\u003ch3\u003eModule Configuration \u0026amp; Nomenclature Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eP-HB\u003c\/b\u003e: Process Harmony Board series designator for modular base mounting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eRMU\u003c\/b\u003e: Repeater Mounting Unit functional hardware designation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003e8000N200\u003c\/b\u003e: Product variant specifying 9-pin D-sub H-Net interface pinout and base topology.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications \u0026amp; Operating Limits\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eP-HB-RMU-8000N200\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSWEDEN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.4 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12.7 x 5.1 x 20.3 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to +70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot specified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLoop Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC +\/-10%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eH-Net In Connection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9-pin D-sub male (isolated 250 V)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIsolation Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500 VAC H-Net-to-earth\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 mm DIN-rail\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHumidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 to 95% RH non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBailey Infi 90 \/ Harmony I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTariff Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8537101190\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePlace of Shipment\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eXiamen, China\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCommunication Architecture \u0026amp; Bus Signal Integration\u003c\/h3\u003e\n\u003cp\u003eThe terminal base repeater manages signal conditioning to prevent attenuation across extended H-Net segments. By stabilizing backplane bus communication velocity across long distances, the unit ensures deterministic data execution without introducing frame errors. Its structural design supports expanded I\/O density scaling throughout local and remote enclosures while preserving firmware flash compatibility across connected controller nodes.\u003c\/p\u003e\n\u003ch3\u003ePackage Fulfillment Details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e1 x ABB P-HB-RMU-8000N200 Terminal Base Repeater unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Physical mounting insert guide sheet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation \u0026amp; Grounding Protocol\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSecure the base unit onto a standard 35 mm DIN-rail until the mechanical retention clip snaps locked.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnect the 24 VDC loop supply wires to the labeled power terminals, verifying voltage falls within +\/-10% tolerances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAlign the 9-pin D-sub male connector with the incoming H-Net interface port and tighten retaining jackscrews.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnect the grounding bus wire directly to the chassis frame to maintain 500 VAC H-Net-to-earth isolation compliance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Hardware Reference FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat connector interface is used for the H-Net input connection?\u003c\/p\u003e\n\u003cp\u003eThe incoming H-Net connection utilizes an integrated 9-pin D-sub male connector rated for 250 V galvanic isolation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat supply voltage limits are required for proper operation?\u003c\/p\u003e\n\u003cp\u003eThe module requires a nominal 24 VDC loop power supply operating strictly within a +\/-10% voltage tolerance window.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat galvanic isolation rating is provided between H-Net and ground?\u003c\/p\u003e\n\u003cp\u003eThe hardware maintains an isolation breakdown rating of 500 VAC measured between H-Net communication lines and earth.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat mounting method is supported by the physical housing?\u003c\/p\u003e\n\u003cp\u003eThe base structure is built for direct snap-on mounting onto standard 35 mm DIN-rail profiles inside field enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat ambient temperature range is permissible for continuous operation?\u003c\/p\u003e\n\u003cp\u003eThe physical components are rated for continuous operation across an ambient temperature range of -40 to +70 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the module require software driver loading or manual parameter setup?\u003c\/p\u003e\n\u003cp\u003eNo, as a physical layer repeating base, the hardware operates transparently without software configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should communication cable shields be terminated on the base?\u003c\/p\u003e\n\u003cp\u003eCable shields must be clamped firmly to the grounding lug to route high-frequency noise directly to panel earth.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the unit operate in high-humidity field environments?\u003c\/p\u003e\n\u003cp\u003eYes, the unit functions in non-condensing relative humidity conditions ranging from 5 to 95% RH.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021117706413,"sku":"P-HB-RMU-8000N200","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb_p-hb-rmu-8000n200_1.jpg?v=1787241425","url":"https:\/\/www.maxwellplc.com\/products\/p-hb-rmu-8000n200-abb-bailey-infi-90-terminal-base-repeater","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}