{"product_id":"omron-v680-hs52-r-cylindrical-antenna-v680-series","title":"Omron V680-HS52-R Cylindrical Antenna V680 Series","description":"\u003cp\u003eConfigured for high-frequency inductive RFID read\/write operations in industrial tracking networks, the \u003cstrong\u003eOmron V680-HS52-R\u003c\/strong\u003e (\u003cstrong\u003eV680-HS52\u003c\/strong\u003e Cylindrical Antenna) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eModel Designation \u0026amp; Feature Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eV680\u003c\/strong\u003e: Industrial RFID System Architecture Platform\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHS\u003c\/strong\u003e: High-Sensitivity Electromagnetic Field Read\/Write Antenna Head\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e52\u003c\/strong\u003e: M22 Threaded Cylindrical Housing (65 mm Overall Length)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR\u003c\/strong\u003e: Flexible Robotic Cable Assembly with Non-Waterproof Interface Connector\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications Summary\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eV680-HS52-R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.85 kg (Net)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003eM22 x 65 mm (Housing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 to 60 deg C (No icing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePowered via V680 Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e20 MOhm min. (at 500 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Resistance\u003c\/td\u003e\n\u003ctd\u003e500 m\/s2 (X, Y, Z directions 3 times each)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd\u003e10 to 500 Hz, 1.5-mm double amplitude at 100 m\/s2 acceleration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP67 (IEC 60529) \/ Oil-resistance equivalent to IP67G (JIS C 0920)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eFlexible cable, non-waterproof connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Bus \u0026amp; Firmware Flash Execution\u003c\/h3\u003e\n\u003cp\u003eThe antenna transducer transfers high-frequency magnetic flux field signals directly to host controllers via deterministic industrial buses. Internal controller firmware flash compatibility protocols verify antenna resonance feedback and transmission framing parameters on system startup, ensuring deterministic packet transfers without introducing backplane latency across PLC interface racks.\u003c\/p\u003e\n\u003ch3\u003eStandard Delivery Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron V680-HS52-R Cylindrical RFID Antenna Unit\u003c\/li\u003e\n\u003cli\u003e2 x M22 Lock Nuts for Panel\/Bracket Mounting\u003c\/li\u003e\n\u003cli\u003e1 x Mounting Instruction Sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Installation \u0026amp; Cable Routing Directives\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the M22 threaded barrel into a pre-drilled bracket hole using supplied lock nuts, maintaining recommended clear space around metallic objects to prevent RF detuning.\u003c\/li\u003e\n\u003cli\u003eSecure the flexible robotic cable along moving machine axis links, ensuring the bending radius remains within specified mechanical limits to eliminate conductor fatigue.\u003c\/li\u003e\n\u003cli\u003eGround the connected V680 controller shield terminal to a low-impedance copper earth bus to prevent high-frequency noise interference.\u003c\/li\u003e\n\u003cli\u003eAvoid routing the non-waterproof connector end through locations exposed to direct liquid spray or oil accumulation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat physical dimensions are specified for the antenna barrel thread?\u003c\/p\u003e\n\u003cp\u003eThe antenna features an M22 threaded outer barrel with a total housing length of 65 mm for standard clearance hole or bracket mounting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat degree of environmental protection applies to the antenna portion?\u003c\/p\u003e\n\u003cp\u003eThe antenna head meets IP67 (IEC 60529) water ingress protection and oil-resistance equivalent to IP67G (JIS C 0920, Appendix 1).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the cable connector end sealed against liquid immersion?\u003c\/p\u003e\n\u003cp\u003eNo, the unit features a flexible robotic cable terminated with a non-waterproof connector, requiring enclosure protection at the connection point.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat insulation resistance value is verified during factory testing?\u003c\/p\u003e\n\u003cp\u003eThe unit provides an insulation resistance of 20 MOhm minimum at 500 VDC between the internal cable terminals and the metallic outer case.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the antenna handle mechanical shock in high-vibration applications?\u003c\/p\u003e\n\u003cp\u003eThe housing withstands shock loads up to 500 m\/s2 applied 3 times each across X, Y, and Z axes (18 impacts total).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does controller firmware flash compatibility affect antenna field operation?\u003c\/p\u003e\n\u003cp\u003eThe host controller firmware validates antenna tuning characteristics during start sequences to prevent communication errors during tag reads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat operational temperature limits must be maintained during active tag scanning?\u003c\/p\u003e\n\u003cp\u003eThe ambient operating temperature range is -10 deg C to 60 deg C, provided no ice formation occurs on the antenna head.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should cable shielding be configured to prevent RF interference?\u003c\/p\u003e\n\u003cp\u003eEnsure the cable shield grounds directly through the mating V680 controller unit to eliminate ground loops and field distortion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306660184237,"sku":"V680-HS52-R","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/v680-hs52-r_1.jpg?v=1790659935","url":"https:\/\/www.maxwellplc.com\/products\/omron-v680-hs52-r-cylindrical-antenna-v680-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}