{"product_id":"omron-drt2-ts04p-temperature-input-terminal-devicenet-series","title":"Omron DRT2-TS04P Temperature Input Terminal DeviceNet Series","description":"\u003cp\u003eThe \u003cstrong\u003eOmron DRT2-TS04P\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDRT2-TS04P\u003c\/strong\u003e Temperature Input Terminal, operates as a dedicated hardware component for platinum-resistance thermometer signal digitizing within DeviceNet fieldbus systems.\u003c\/p\u003e\n\u003ch3\u003eTerminal Hardware Structure\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDRT2\u003c\/strong\u003e: Advanced DeviceNet smart slave terminal platform with integral diagnostic monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTS\u003c\/strong\u003e: Temperature sensor input functional hardware block.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e04\u003c\/strong\u003e: 4-channel analog measurement point capacity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eP\u003c\/strong\u003e: Platinum resistance thermometer (Pt100\/JPt100) sensor element compatibility.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Data Summary\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDRT2-TS04P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.16 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e15 x 15 x 5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e70 mA max. at 24 VDC, 110 mA max. at 11 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003ePlatinum-resistance thermometer (Pt100 \/ JPt100)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Points\u003c\/td\u003e\n\u003ctd\u003e4 inputs (4 words allocated, or 8 words in 1\/100 display mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunications Voltage\u003c\/td\u003e\n\u003ctd\u003e11 to 25 VDC (via bus connector)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Power Voltage\u003c\/td\u003e\n\u003ctd\u003e100 to 240 VAC or 24 VAC\/12 to 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDIP Switch Configuration\u003c\/td\u003e\n\u003ctd\u003eIntegrated hardware DIP switches provided\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e25% to 85% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-25 to 65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Integration \u0026amp; Deterministic Data Processing\u003c\/h3\u003e\n\u003cp\u003eThe DRT2-TS04P provides linear RTD resistance processing without bottlenecking bus communication velocity. Internal firmware logic handles high-precision resistance-to-digital scaling and supports software selection between standard or 1\/100 resolution display modes. Optimized data framing enables steady I\/O density scaling across master PLC scan cycles, ensuring full firmware flash compatibility for deterministic data cyclic polling over DeviceNet.\u003c\/p\u003e\n\u003ch3\u003eShipment Box Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron DRT2-TS04P Temperature Input Terminal\u003c\/li\u003e\n\u003cli\u003e1 x 5-Pin DeviceNet Open Network Plug Connector\u003c\/li\u003e\n\u003cli\u003e1 x Instruction Sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWiring Directives \u0026amp; Installation Rules\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDIN-Rail Terminal Mounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLatch the terminal assembly securely onto a 35-mm DIN rail or fasten via mounting holes to an enclosure backplate.\u003c\/li\u003e\n\u003cli\u003eMaintain minimum clearance around the top and bottom vents to ensure unimpeded air circulation for internal thermistor references.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eRTD Sensor Lead Termination\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRun 3-wire RTD extension leads in separate shielded conduits to suppress coupled high-frequency industrial noise.\u003c\/li\u003e\n\u003cli\u003eSet the DIP switches to match the connected sensor type (Pt100 vs. JPt100) and required memory mapping configuration prior to applying bus power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat sensor elements can be connected to the DRT2-TS04P input channels?\u003c\/p\u003e\n\u003cp\u003eThe module accepts standard platinum resistance thermometers, specifically Pt100 and JPt100 temperature sensors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many network input words are allocated at the master unit for this terminal?\u003c\/p\u003e\n\u003cp\u003eThe terminal allocates 4 input words in standard mode, or 8 input words when the 1\/100 high-resolution display mode is active.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum current draw from the DeviceNet communications line?\u003c\/p\u003e\n\u003cp\u003eThe maximum communications current consumption is 70 mA at 24 VDC and 110 mA at 11 VDC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the ambient storage temperature range for this hardware?\u003c\/p\u003e\n\u003cp\u003eThe terminal can be safely stored in non-condensing environments ranging from -25 deg C to 65 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAre hardware DIP switches built into the module for field configuration?\u003c\/p\u003e\n\u003cp\u003eYes, integrated DIP switches are provided to set parameters such as sensor type and resolution modes directly on the unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the module require an external power supply in addition to bus power?\u003c\/p\u003e\n\u003cp\u003eYes, the internal circuitry requires operating power rated at 100 to 240 VAC or 24 VAC\/12 to 24 VDC alongside the DeviceNet bus voltage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should cable shielding be handled for long RTD sensor runs?\u003c\/p\u003e\n\u003cp\u003eShielded 3-wire cables must be used for RTD runs, with the shield grounded at a single panel ground point to prevent noise loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the DRT2-TS04P be installed directly on a DIN rail?\u003c\/p\u003e\n\u003cp\u003eYes, the enclosure is equipped with an integral locking clip designed for standard 35-mm DIN track mounting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306660479149,"sku":"DRT2-TS04P","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/omron_drt2-ts04p_1.jpg?v=1789695048","url":"https:\/\/www.maxwellplc.com\/products\/omron-drt2-ts04p-temperature-input-terminal-devicenet-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}