{"product_id":"omron-cp1w-ts102-temperature-sensor-unit-cp1w-series","title":"Omron CP1W-TS102 Temperature Sensor Unit CP1W Series","description":"\u003cp\u003eConfigured for platinum resistance thermometer input processing in Omron CP1-series PLC platforms, the \u003cstrong\u003eOmron CP1W-TS102\u003c\/strong\u003e (\u003cstrong\u003eCP1W-TS102\u003c\/strong\u003e Temperature Sensor Unit) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eTechnical Identifier Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries Prefix (CP1W):\u003c\/strong\u003e Expansion I\/O unit for CP1H, CP1L, and CP1E PLC systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction Code (TS):\u003c\/strong\u003e Temperature sensor input expansion module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Type Code (1):\u003c\/strong\u003e RTD \/ Platinum resistance thermometer input configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Density Code (02):\u003c\/strong\u003e 4-channel RTD input processing capacity (Pt100 \/ JPt100)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCP1W-TS102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.250 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e5.0 cm x 8.6 cm x 9.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e8.0 cm x 11.0 cm x 11.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 VDC: 54 mA max. \/ 24 VDC: 73 mA max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e4 inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Temperature Sensors\u003c\/td\u003e\n\u003ctd\u003ePlatinum resistance thermometer (Pt100 or JPt100, switchable; uniform across all channels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAllocated Input Words\u003c\/td\u003e\n\u003ctd\u003e4 words (1 word per input channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Time\u003c\/td\u003e\n\u003ctd\u003e250 ms for 2 or 4 input points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConverted Temperature Data\u003c\/td\u003e\n\u003ctd\u003e16-bit binary data (4-digit hexadecimal format)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003ePhotocouplers between all temperature input signals and internal backplane logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePLC Determinism and Backplane Bus Velocity\u003c\/h3\u003e\n\u003cp\u003eThe CP1W-TS102 expansion interface transfers 16-bit binary RTD temperature values directly across the internal CP-series backplane bus during the PLC cyclic scan I\/O refresh window. High-speed backplane velocity ensures 4 allocated input words update deterministically without introducing CPU processing jitter or expanding cyclic execution times.\u003c\/p\u003e\n\u003cp\u003eThe modular expansion bus permits scaled I\/O density integration by chaining multiple CP1W modules side-by-side using the built-in flat ribbon bus connector. Integrated photocoupler isolation between temperature input channels and CPU logic prevents ground loops and blocks common-mode noise propagation across expansion racks.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Ordering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x Omron CP1W-TS102 Temperature Sensor Unit\u003c\/li\u003e\n\u003cli\u003e1x Integrated Expansion Bus Cable\u003c\/li\u003e\n\u003cli\u003e1x Removable Terminal Block Assembly\u003c\/li\u003e\n\u003cli\u003e1x CP1W Hardware Installation Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN-Rail Mounting:\u003c\/strong\u003e Mount the unit on a 35 mm DIN rail (PFP-50N\/PFP-100N). Ensure side locking mechanisms lock securely to prevent lateral vibration displacement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Connection:\u003c\/strong\u003e Plug the integrated flat ribbon cable directly into the expansion bus connector of the preceding CPU or expansion module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRTD Sensor Wiring:\u003c\/strong\u003e Wire 3-wire Pt100\/JPt100 sensors ensuring equal wire resistance across conductors A, B, and b to maintain measurement accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding and Shielding:\u003c\/strong\u003e Terminate RTD signal cable shielding at a single point using a 360-deg braid grounding clamp attached to the protective earth terminal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Tightening:\u003c\/strong\u003e Fasten terminal block screws to a torque rating of 0.5 N-m to prevent contact degradation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat sensor types are supported by the CP1W-TS102?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module supports Pt100 and JPt100 platinum resistance thermometers. All 4 channels must be set to the same sensor type.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow many input channels and CIO words does the module allocate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module features 4 RTD input channels and allocates 4 input words in the PLC memory map.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the analog-to-digital conversion time for all 4 channels?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe conversion time is 250 ms total for 2 or 4 active input channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat format is used to store converted temperature values in PLC memory?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTemperature values are formatted as 16-bit binary data expressed in 4-digit hexadecimal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat current consumption does the module draw from the expansion bus?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module draws a maximum of 54 mA at 5 VDC and 73 mA at 24 VDC from the backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat isolation mechanisms protect internal CPU logic from field interference?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePhotocouplers provide galvanic isolation between individual temperature input signals and internal CPU backplane logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan different sensor types be mixed across channels on a single module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, while the unit is switchable between Pt100 and JPt100, the same sensor type must be used across all 4 inputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs hot-swapping permitted for this expansion module during PLC operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, removing or inserting expansion units while the base controller is energized is strictly prohibited.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306624139437,"sku":"CP1W-TS102","price":153.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/CP1W-TS102_1.jpg?v=1788839567","url":"https:\/\/www.maxwellplc.com\/products\/omron-cp1w-ts102-temperature-sensor-unit-cp1w-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}