{"product_id":"omron-cp1l-m40dr-d-programmable-controller-sysmac-cp1l-series","title":"Omron CP1L-M40DR-D Programmable Controller SYSMAC CP1L Series","description":"\u003cp\u003eConfigured for high-speed sequence processing and discrete control in SYSMAC CP1L architectures, the \u003cstrong\u003eOmron CP1L-M40DR-D\u003c\/strong\u003e (\u003cstrong\u003eCP1L-M40DR-D\u003c\/strong\u003e Programmable Controller) provides direct physical\/electrical execution across 24 DC inputs and 16 electromechanical relay outputs.\u003c\/p\u003e\n\u003ch3\u003eTechnical Identifier Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Hardware Model:\u003c\/strong\u003e CP1L-M40DR-D\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Part Number:\u003c\/strong\u003e CP1L-M40DR-D\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e High Performing Programmable Controller Unit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries Family:\u003c\/strong\u003e Omron SYSMAC CP1L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCPU Class:\u003c\/strong\u003e CP1L-M (Medium-scale CPU unit with 40 built-in I\/O points)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgram Capacity:\u003c\/strong\u003e 10K steps memory capacity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiscrete I\/O Breakdown:\u003c\/strong\u003e 24 inputs (24 VDC), 16 relay outputs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCP1L-M40DR-D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.61 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e15.0 cm x 11.0 cm x 8.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e19.0 cm x 15.0 cm x 11.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC (20.4 to 26.4 VDC operating range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e20 W max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstruction Execution Time\u003c\/td\u003e\n\u003ctd\u003eBasic: 0.55 us min., Special: 4.1 us min.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh-Speed Counters\u003c\/td\u003e\n\u003ctd\u003e100 kHz, 4 axes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Expanded I\/O Density\u003c\/td\u003e\n\u003ctd\u003e160 points (40 built-in + 3 expansion units max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eOmron Backplane Bus Velocity \u0026amp; Real-Time Logic Execution\u003c\/h3\u003e\n\u003cp\u003eThe CP1L-M40DR-D features an optimized memory structure that processes basic instruction execution cycles in 0.55 us min. Internal cyclic scanning operates with immediate input\/output refreshing across 1,600 CIO bits (100 input words \/ 100 output words). The system CPU expansion backplane supports local attachment of up to 3 CP-series expansion or expansion I\/O units, scaling overall hardware execution capacity to 160 total I\/O points. Firmware flash non-volatile memory secures user programs, function block definitions (up to 128 definitions and 256 instances), and system parameters during power removal.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Ordering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x Omron CP1L-M40DR-D Programmable Controller Unit\u003c\/li\u003e\n\u003cli\u003e1x Removable terminal block protective cover unit\u003c\/li\u003e\n\u003cli\u003e1x Hardware specification instruction sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSubrack Mounting:\u003c\/strong\u003e Secure the CP1L-M40DR-D onto a standard 35 mm DIN rail or surface-mount directly inside the control enclosure using M4 screws, maintaining a minimum 50 mm clearance above and below for thermal convection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Power Supply Wiring:\u003c\/strong\u003e Connect the main 24 VDC operating supply to the designated DC terminal block using AWG 18 to AWG 14 insulated copper wire.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay Output Protection:\u003c\/strong\u003e Install inductive load suppression devices (RC networks across AC field loads or flyback diodes across DC field loads) directly at switched field devices to suppress switching transients.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Protocol:\u003c\/strong\u003e Connect the Functional Earth (FE) terminal to the central copper panel ground bar using a short, heavy-gauge copper conductor with measured ground resistance under 100 Ohms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eIs hot-swapping permitted for expansion modules attached to the CP1L-M40DR-D?\u003c\/p\u003e\n\u003cp\u003eNo. Main system power must be completely turned off before installing or removing local CP-series expansion units to avoid backplane bus damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat operating input voltage range is required for the CP1L-M40DR-D?\u003c\/p\u003e\n\u003cp\u003eThe controller requires a nominal 24 VDC power supply with an acceptable operational range between 20.4 VDC and 26.4 VDC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat high-speed counting capabilities are integrated into this CPU model?\u003c\/p\u003e\n\u003cp\u003eThe hardware includes 4-axis high-speed counter inputs supporting response frequencies up to 100 kHz for differential or single-phase pulse train acquisition.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many total I\/O points can be controlled using local expansion units?\u003c\/p\u003e\n\u003cp\u003eThe CPU provides 40 built-in I\/O points and supports up to 3 expansion units (40 points each), scaling total system density to 160 I\/O points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat memory structure is allocated for holding relay data during power cycles?\u003c\/p\u003e\n\u003cp\u003eThe holding area consists of 8,192 bits (512 words from H0.00 to H511.15) reserved for non-volatile parameter retainment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat minimum pulse width is recognized on the quick-response input terminals?\u003c\/p\u003e\n\u003cp\u003eThe quick-response input channels accept high-speed field pulses with a minimum pulse width requirement of 50 us or less.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat cable shielding standard must be applied to serial and high-speed input signals?\u003c\/p\u003e\n\u003cp\u003eSignal and serial wiring must utilize overall twisted-pair shielded cables with 360-deg braid shield clamping connected directly to panel earth.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat environment conditions are required for non-operating storage of spare modules?\u003c\/p\u003e\n\u003cp\u003eUninstalled spare CPUs must remain stored inside anti-static bags in ambient conditions between -20 and +75 deg C in non-condensing relative humidity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306668900525,"sku":"CP1L-M40DR-D","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/CP1L-M40DR-D_1.jpg?v=1788572827","url":"https:\/\/www.maxwellplc.com\/products\/omron-cp1l-m40dr-d-programmable-controller-sysmac-cp1l-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}