{"product_id":"omron-cp1l-m40dr-a-cp1l-series-programmable-controller","title":"Omron CP1L-M40DR-A CP1L Series Programmable Controller","description":"\u003cp\u003eThe \u003cb\u003eOmron CP1L-M40DR-A\u003c\/b\u003e, also cataloged as the \u003cb\u003eCP1L-M40DR-A\u003c\/b\u003e Programmable Controller, operates as a dedicated hardware component for discrete logical processing and field device switching within CP1L network architectures.\u003c\/p\u003e\n\u003ch3\u003eTechnical Identifier Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eBase Model:\u003c\/b\u003e CP1L\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eCPU Class:\u003c\/b\u003e M (40 I\/O Points)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eInput Points:\u003c\/b\u003e 24 DC Inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eOutput Points:\u003c\/b\u003e 16 Relay Outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003ePower Supply Voltage:\u003c\/b\u003e 100 to 240 VAC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eOutput Configuration:\u003c\/b\u003e Electromechanical Relay\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCP1L-M40DR-A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOmron\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eJapan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.61 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15.0 cm x 11.0 cm x 8.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18.0 cm x 14.0 cm x 11.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 55 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 VA max. at 100 to 240 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProgram Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10K steps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExecution Speed\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBasic instructions: 0.55 us min.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommon Processing Time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.4 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eData Memory Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32K words (DM Area: 10K words, EM Area: 10K words x 1 bank)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-Speed Counters\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 kHz, 4 axes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax Expansion Capability\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3 CP-series Expansion \/ Expansion I\/O Units\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax Total I\/O Points\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e160 points (40 built-in + 120 expansion)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOmron PLC Backplane Bus Velocity \u0026amp; Expansion Determinism\u003c\/h3\u003e\n\u003cp\u003eThe CP1L-M40DR-A host processor executes cyclic scanning with immediate I\/O refreshing, delivering high-speed execution through direct bus interconnects. The local system bus handles high-density I\/O expansion up to 3 add-on modules without degrading the 0.55 us basic instruction cycle time. Built-in high-speed counter inputs (4 axes at 100 kHz) and quick-response inputs (50 us min. pulse width) process directly through hardware interrupts, bypassing standard scan delays to maintain deterministic execution across complex automated tasks.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Ordering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e1x Omron CP1L-M40DR-A Programmable Controller\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1x Terminal block protective cover assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1x Hardware installation instruction manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eDIN Rail Mounting:\u003c\/b\u003e Secure the controller on a 35 mm DIN rail (TH35-7.5 or TH35-15) using the rear locking mechanism. Maintain at least 50 mm clearance above and below the housing for convection cooling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eAC Supply Wiring:\u003c\/b\u003e Connect 100 to 240 VAC power to terminals L1 and L2\/N. Use AWG 14 to AWG 18 wire sizes and torque terminal screws to 0.5 N m.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eShielding \u0026amp; Grounding:\u003c\/b\u003e Connect the functional ground (FG) terminal directly to a dedicated earth electrode with under 100 Ohm resistance. Run field I\/O lines in separate conduits from AC power wiring by at least 100 mm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eExpansion Connection:\u003c\/b\u003e Remove the expansion bus connector cover on the right side of the unit before locking CP-series expansion modules onto the side bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum backplane expansion limit for the CP1L-M40DR-A CPU unit?\u003c\/p\u003e\n\u003cp\u003eThe unit supports a maximum of 3 CP-series expansion units or expansion I\/O units, bringing the maximum total system capacity to 160 I\/O points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the electromechanical relay outputs be hot-swapped during operation?\u003c\/p\u003e\n\u003cp\u003eNo. The CP1L-M40DR-A uses an integrated, non-modular terminal block design; all AC main power and field supply power must be isolated prior to maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat signal input pulse width is required for the quick-response input terminals?\u003c\/p\u003e\n\u003cp\u003eQuick-response inputs register digital pulses with a minimum input pulse width as short as 50 us max., bypassing standard scan cycle input filtering.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat programming languages are supported for function block execution?\u003c\/p\u003e\n\u003cp\u003eFunction block definitions support both standard Ladder Diagrams and Structured Text (ST) languages, allowing up to 128 definitions and 256 instances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat cable parameter is required for the functional grounding terminal?\u003c\/p\u003e\n\u003cp\u003eUse a copper conductor with a minimum cross-sectional area of 2.0 mm2 connected directly to a ground electrode without creating ground loops with power circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the CP1L-M40DR-A provide built-in high-speed pulse outputs?\u003c\/p\u003e\n\u003cp\u003eNo. Models with relay outputs (CP1L-M40DR-A) do not feature pulse output functions; transistor output models are required for 100 kHz pulse outputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many total task assignments can be configured in the CPU memory?\u003c\/p\u003e\n\u003cp\u003eThe execution engine supports up to 288 total tasks, configured specifically as 32 cyclic tasks and 256 interrupt tasks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the thermal derating requirement at the maximum operating limit of 55 deg C?\u003c\/p\u003e\n\u003cp\u003eAt 55 deg C, ensure total simultaneous ON ratio across all input and output channels does not exceed 80 percent of total hardware density to avoid internal thermal accumulation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306667819181,"sku":"CP1L-M40DR-A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/omron_cp1l-m40dr-a_4.jpg?v=1788572973","url":"https:\/\/www.maxwellplc.com\/products\/omron-cp1l-m40dr-a-cp1l-series-programmable-controller","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}