{"product_id":"omron-cj1w-da041-analog-output-module-sysmac-cj-series","title":"Omron CJ1W-DA041 Analog Output Module SYSMAC CJ Series","description":"\u003cp\u003eThe \u003cstrong\u003eOmron CJ1W-DA041\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCJ1W-DA041\u003c\/strong\u003e Analog Output Unit, operates as a dedicated hardware component for multi-range analog signal generation within SYSMAC CJ Series platforms.\u003c\/p\u003e\n\u003ch3\u003eTechnical Identifier Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Omron\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Model:\u003c\/strong\u003e CJ1W-DA041\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Part Number:\u003c\/strong\u003e CJ1W-DA041\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries Name:\u003c\/strong\u003e SYSMAC CJ Series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Analog Output Unit (4 Channels)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Classification:\u003c\/strong\u003e CJ-series Special I\/O Unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCJ1W-DA041\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.15 kg max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3.1 cm x 9.0 cm x 6.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e5.0 cm x 11.0 cm x 9.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C ... +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e0.70 W (140 mA max. at 5 VDC from PLC backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC, 200 mA max. (Inrush: 20 A max., pulse width: 1 ms min.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e4 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal Ranges\u003c\/td\u003e\n\u003ctd\u003e1 to 5 V, 4 to 20 mA, 0 to 5 V, 0 to 10 V, -10 to 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Impedance\u003c\/td\u003e\n\u003ctd\u003e0.5 Ohm max. (for voltage output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Output Current\u003c\/td\u003e\n\u003ctd\u003e12 mA per point (for voltage output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Permissible Load Resistance\u003c\/td\u003e\n\u003ctd\u003e600 Ohm (for current output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Resolution\u003c\/td\u003e\n\u003ctd\u003e4,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSet Data Format\u003c\/td\u003e\n\u003ctd\u003e16-bit binary data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (25 deg C)\u003c\/td\u003e\n\u003ctd\u003eVoltage: +\/-0.3% of F.S., Current: +\/-0.5% of F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (0 deg C to 55 deg C)\u003c\/td\u003e\n\u003ctd\u003eVoltage: +\/-0.5% of F.S., Current: +\/-0.8% of F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD\/A Conversion Period\u003c\/td\u003e\n\u003ctd\u003e1.0 ms per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003ePhotocoupler isolation between I\/O and Controller signals (No isolation between I\/O channels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Terminals\u003c\/td\u003e\n\u003ctd\u003e18-point detachable terminal block (M3 screws)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Functions\u003c\/td\u003e\n\u003ctd\u003eOutput hold function (CLR, HOLD, MAX)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePLC Controller Processing \u0026amp; Backplane Communication\u003c\/h3\u003e\n\u003cp\u003eThe CJ1W-DA041 transfers digital 16-bit binary set data across the internal backplane bus velocity framework to output precision current and voltage loops. High-density I\/O density scaling allows 4 independently configured channels per slot while maintaining direct synchronization with CPU memory mapping. Built-in photocoupler isolation insulates the internal controller logic from external field signals, maintaining deterministic update cycles with a fixed D\/A conversion execution period of 1.0 ms per active channel across firmware flash compatibility revisions.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Ordering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x Omron CJ1W-DA041 Analog Output Unit\u003c\/li\u003e\n\u003cli\u003e1x 18-Point Detachable Terminal Block (M3 Screws)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Seat the unit into the assigned CJ1 CPU or expansion rack slot and slide the upper and lower locking levers to secure it to the DIN rail.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect field output signal cables to the 18-point detachable terminal block using M3 terminal screws.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e Wire voltage and current signals using twisted-pair cables protected by 360-deg braid shielding bonded to the enclosure ground rail.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the CJ1 backplane functional earth (FE) terminal to the central control panel earth bus via a low-impedance copper strap.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat output signal ranges are supported by the CJ1W-DA041?\u003c\/p\u003e\n\u003cp\u003eThe module supports 1 to 5 V, 4 to 20 mA, 0 to 5 V, 0 to 10 V, and -10 to 10 V configurable analog signal ranges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs channel-to-channel isolation provided on the CJ1W-DA041?\u003c\/p\u003e\n\u003cp\u003ePhotocoupler isolation is provided between I\/O circuits and the controller, but there is no channel-to-channel isolation between individual output signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat external power supply parameters are required for operation?\u003c\/p\u003e\n\u003cp\u003eThe module requires an external 24 VDC supply rated at 200 mA max. with an inrush current handling capacity of 20 A max. (1 ms min. pulse).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat physical dimensions apply to the CJ1W-DA041 hardware?\u003c\/p\u003e\n\u003cp\u003eThe module physical dimensions measure 3.1 cm x 9.0 cm x 6.5 cm with a maximum overall weight of 0.15 kg.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the D\/A conversion period per point on the CJ1W-DA041?\u003c\/p\u003e\n\u003cp\u003eThe digital-to-analog conversion period is executed at 1.0 ms per active output point.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum load resistance for the 4 to 20 mA current output range?\u003c\/p\u003e\n\u003cp\u003eThe current output mode supports a maximum permissible load resistance of 600 Ohm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the output hold function operate upon PLC controller stop?\u003c\/p\u003e\n\u003cp\u003eThe output hold function drives channels to a predefined state (CLR, HOLD, or MAX) when controller execution stops or an error occurs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat terminal block style is utilized for field signal terminations?\u003c\/p\u003e\n\u003cp\u003eField conductors terminate at an 18-point detachable terminal block equipped with standard M3 screw connectors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306676240557,"sku":"CJ1W-DA041","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/CJ1W-DA041_2.jpg?v=1788155445","url":"https:\/\/www.maxwellplc.com\/products\/omron-cj1w-da041-analog-output-module-sysmac-cj-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}