{"product_id":"nx102-1220-omron-sysmac-nx1-modular-cpu","title":"NX102-1220 Omron Sysmac NX1 Modular CPU","description":"\u003cp\u003eThe \u003cstrong\u003eOmron NX102-1220\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eNX102-1220\u003c\/strong\u003e Sysmac NX1 Modular CPU, operates as a dedicated hardware component for multi-axis sequence execution and real-time motion control within Sysmac automation architectures.\u003c\/p\u003e\n\u003ch3\u003ePart Number Code Structure\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNX102\u003c\/strong\u003e: Compact NX1 series machine automation controller hardware platform.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e12\u003c\/strong\u003e: Integrated database connectivity functionality with 8 synchronous motion axes capability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e20\u003c\/strong\u003e: 5 MB program execution memory specification with OPC-UA client\/server integration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOperating Parameters\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNX102-1220\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.590 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2.000 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Dimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e6.60 cm x 10.00 cm x 10.00 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e18.00 cm x 15.00 cm x 12.00 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e12.20 W max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgram Memory\u003c\/td\u003e\n\u003ctd\u003e5 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVariables Memory\u003c\/td\u003e\n\u003ctd\u003e33.5 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Task Cycle Time\u003c\/td\u003e\n\u003ctd\u003e1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSynchronous Motion Axes\u003c\/td\u003e\n\u003ctd\u003e8 axes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePTP Axes\u003c\/td\u003e\n\u003ctd\u003e4 axes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Axes\u003c\/td\u003e\n\u003ctd\u003e15 axes (including virtual axes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-Board Interfaces\u003c\/td\u003e\n\u003ctd\u003eEtherCAT Master, EtherNet\/IP, Ethernet TCP\/IP, USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote I\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e64 nodes max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Expansion Units\u003c\/td\u003e\n\u003ctd\u003e32 NX I\/O units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Bus Architecture\u003c\/h3\u003e\n\u003cp\u003eThe module interfaces directly with EtherNet\/IP deterministic networks via the NX bus system to maintain synchronous data exchange. Optimized backplane bus communication velocity allows high-density I\/O density scaling profiles, while firmware flash compatibility ensures zero execution delays during high-speed analog loop processing.\u003c\/p\u003e\n\u003ch3\u003eScope of Delivery\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron NX102-1220 Sysmac NX1 Modular CPU\u003c\/li\u003e\n\u003cli\u003e1 x End cover unit (NX-END02)\u003c\/li\u003e\n\u003cli\u003e1 x Power supply connector\u003c\/li\u003e\n\u003cli\u003e1 x Hardware installation guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Cabinet Installation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the controller vertically onto a standard 35 mm DIN rail inside a protective industrial enclosure.\u003c\/li\u003e\n\u003cli\u003eProvide at least 30 mm of free air space above and below the module to facilitate natural thermal dissipation.\u003c\/li\u003e\n\u003cli\u003eConnect the main functional ground terminal directly to a single-point earth ground bar using a short green\/yellow wire.\u003c\/li\u003e\n\u003cli\u003eConfirm that the bus connector side cover is securely snapped into place before applying power to the unit.\u003c\/li\u003e\n\u003cli\u003eRoute high-voltage AC cables separately from low-voltage Ethernet and NX bus communication lines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Support FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the primary task cycle time limit for motion axis calculations on the NX102-1220 CPU?\u003c\/p\u003e\n\u003cp\u003eThe controller executes the primary periodic task cycle at a maximum speed of 1 ms for synchronized motion routines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the NX102-1220 unit support direct relational database integration without external gateways?\u003c\/p\u003e\n\u003cp\u003eYes, the CPU includes built-in database client software for direct SQL connections to MySQL, Oracle, and MS SQL.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many remote I\/O nodes can be connected via the built-in EtherCAT master port?\u003c\/p\u003e\n\u003cp\u003eThe EtherCAT master port supports up to 64 remote I\/O slave nodes operating on a deterministic field network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat communication option boards can be inserted into the front option card slots?\u003c\/p\u003e\n\u003cp\u003eThe CPU accepts serial communication option boards supporting standard RS-232C, RS-422, and RS-485 interfaces.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs an external SD memory card mandatory for running user PLC programs?\u003c\/p\u003e\n\u003cp\u003eNo, user programs run from internal non-volatile memory; SD cards are used for logging, backups, and recipe storage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum number of local expansion NX I\/O modules supported on the CPU rack?\u003c\/p\u003e\n\u003cp\u003eThe CPU backplane interface supports up to 32 NX series expansion units mounted directly on the local DIN rail.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the unit manage clock retention during total external DC power outages?\u003c\/p\u003e\n\u003cp\u003eAn internal battery retains clock calendar data and non-volatile variables during extended power failure events.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the USB service port be utilized for real-time EtherCAT field bus communication?\u003c\/p\u003e\n\u003cp\u003eNo, the built-in USB port is restricted exclusively to programming, firmware maintenance, and Sysmac Studio setups.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306667589805,"sku":"NX102-1220","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/NX102-1220-2.jpg?v=1790688340","url":"https:\/\/www.maxwellplc.com\/products\/nx102-1220-omron-sysmac-nx1-modular-cpu","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}