{"product_id":"nx102-1020-omron-sysmac-nx1-series-modular-cpu","title":"NX102-1020 Omron Sysmac NX1 Series Modular CPU","description":"\u003cp\u003eThe \u003cstrong\u003eOmron NX102-1020\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eNX102-1020\u003c\/strong\u003e Sysmac NX1 Modular CPU, operates as a dedicated hardware component for multi-axis motion synchronization and sequence control execution within EtherCAT and EtherNet\/IP automation networks.\u003c\/p\u003e\n\u003ch3\u003eArchitecture \u0026amp; System Configuration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries Architecture\u003c\/strong\u003e: Sysmac NX1 compact machine controller platform\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAxis Control Capacity\u003c\/strong\u003e: 2 synchronized motion axes, 4 PTP axes, up to 15 total axes including virtual channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory Allocation\u003c\/strong\u003e: 5 MB user program capacity, 33.5 MB variables memory\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpansion Expansion Limits\u003c\/strong\u003e: Up to 32 direct NX I\/O expansion units via internal NX I\/O Bus\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNode Connectivity\u003c\/strong\u003e: Direct integration for up to 64 remote I\/O nodes via standard fieldbus ports\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \u0026amp; Environmental Attributes\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNX102-1020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.55 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2.00 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e10.0 cm x 6.6 cm x 10.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e12.5 W nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Task Cycle Time\u003c\/td\u003e\n\u003ctd\u003e1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Ports\u003c\/td\u003e\n\u003ctd\u003eEtherCAT Master, EtherNet\/IP, Ethernet TCP\/IP, USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Interfaces\u003c\/td\u003e\n\u003ctd\u003eRS-232C, RS-422, RS-485 (via optional modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocol Support\u003c\/td\u003e\n\u003ctd\u003eDB connection, Motion control, OPC-UA, Position control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHigh-Speed Deterministic Processing \u0026amp; Network Execution\u003c\/h3\u003e\n\u003cp\u003eThe CPU leverages EtherNet\/IP and deterministic EtherCAT master capabilities to drive high-speed backplane bus communication velocity across connected modules. Built-in I\/O density scaling allows seamless hardware synchronization, while firmware flash compatibility ensures stable cross-platform variable mapping during real-time database transactions and OPC-UA connectivity.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron NX102-1020 Sysmac NX1 Modular CPU Unit\u003c\/li\u003e\n\u003cli\u003e1 x Right-Side End Cover Plate (NX-END02)\u003c\/li\u003e\n\u003cli\u003e1 x Terminal Block Assembly for 24 VDC Power Supply Input\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnclosure Mount \u0026amp; Cabinet Wiring Rules\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Assembly\u003c\/strong\u003e: Mount the unit onto a standard 35 mm symmetric DIN rail, maintaining at least 30 mm vertical clearance for airflow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus Line Termination\u003c\/strong\u003e: Secure the terminal end cover (NX-END02) on the rightmost expansion unit to establish internal backplane continuity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding\u003c\/strong\u003e: Ground the EtherCAT and EtherNet\/IP shielded twisted-pair cables through low-impedance grounding clamps at the duct entry.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-Swap Restriction\u003c\/strong\u003e: Power off the main 24 VDC bus prior to attaching or disconnecting local NX I\/O expansion slices to prevent interface bus damage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat primary fieldbus protocols are natively supported on the main physical ports?\u003c\/p\u003e\n\u003cp\u003eThe integrated Ethernet ports natively support EtherCAT Master, EtherNet\/IP, standard Ethernet TCP\/IP, and OPC-UA server communications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan NX series I\/O expansion units be connected directly to the CPU unit?\u003c\/p\u003e\n\u003cp\u003eYes, the CPU supports direct side-by-side mounting of up to 32 local NX I\/O modules across its internal NX I\/O backplane bus interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the controller support hot-swapping of connected NX I\/O modules during runtime?\u003c\/p\u003e\n\u003cp\u003eNo, hot-swapping local I\/O modules on the CPU backplane is not supported; the system power supply must be interrupted before removal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are serial communication interfaces added to the main controller?\u003c\/p\u003e\n\u003cp\u003eSerial communication capability (RS-232C, RS-422, or RS-485) is achieved by mounting optional NX-series serial communications units to the bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the fastest deterministic primary task execution cycle time for motion loops?\u003c\/p\u003e\n\u003cp\u003eThe controller executes logic programs and synchronized motion control loops with a primary task cycle time down to 1 ms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat are the specific motion axis constraints for coordinated servo positioning?\u003c\/p\u003e\n\u003cp\u003eThe unit supports a maximum of 15 total axes, strictly categorized as 2 fully synchronized axes, 4 PTP axes, and remaining virtual axes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs external software configuration required for direct enterprise database connection?\u003c\/p\u003e\n\u003cp\u003eThe controller executes direct SQL queries to databases via internal function blocks without requiring middleware translation servers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat firmware flash compatibility considerations apply during system maintenance?\u003c\/p\u003e\n\u003cp\u003eFirmware images must match the project version compiled in Sysmac Studio to prevent execution halts during memory transfer cycles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306678927533,"sku":"NX102-1020","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/omron_nx102-1020_3.jpg?v=1787635885","url":"https:\/\/www.maxwellplc.com\/products\/nx102-1020-omron-sysmac-nx1-series-modular-cpu","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}