{"product_id":"nx-ts2201-omron-nx-series-temperature-input-unit","title":"NX-TS2201 Omron NX Series Temperature Input Unit","description":"\u003cp data-path-to-node=\"4\"\u003eConfigured for resistance thermometer measurement loops within industrial backplane architectures, the \u003cb data-path-to-node=\"4\" data-index-in-node=\"103\"\u003eOmron NX-TS2201\u003c\/b\u003e (\u003cb data-path-to-node=\"4\" data-index-in-node=\"120\"\u003eNX-TS2201\u003c\/b\u003e Temperature Input Unit) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"5\"\u003eModel Suffix Breakdown \u0026amp; Functional Design\u003c\/h3\u003e\n\u003cp data-path-to-node=\"6\"\u003eThe part number denotes specific structural attributes: \"TS\" designates a Temperature Input module, \"2\" indicates 2 input channels, \"2\" specifies Resistance Thermometer sensor compatibility, and \"01\" defines a conversion time of 250 ms per unit, a maximum resolution of 0.1 deg C, and Free-Run backplane refreshing.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"7\"\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"8\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,1,0,0\"\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,1,1,0\"\u003eNX-TS2201\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,2,0,0\"\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,2,1,0\"\u003eOmron\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,3,0,0\"\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,3,1,0\"\u003eJapan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,4,0,0\"\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,4,1,0\"\u003e0.07 Kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,5,0,0\"\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,5,1,0\"\u003e12 x 100 x 71 mm (Shipping Weight 1 Kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,6,0,0\"\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,6,1,0\"\u003e0 deg C to 55 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,7,0,0\"\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,7,1,0\"\u003e1.25 W max. (CPU\/Control Unit), 0.90 W max. (Coupler Unit)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,8,0,0\"\u003eInput Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,8,1,0\"\u003e2 points (Resistance Thermometer)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,9,0,0\"\u003eSupported Sensors\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,9,1,0\"\u003ePt100 (three-wire), Pt1000 (three-wire)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,10,0,0\"\u003eConversion Time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,10,1,0\"\u003e250 ms\/Unit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,11,0,0\"\u003eInput Detection Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,11,1,0\"\u003eApprox. 0.25 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-path-to-node=\"9\"\u003eBackplane Bus \u0026amp; Network Synchronization\u003c\/h3\u003e\n\u003cp data-path-to-node=\"10\"\u003eBackplane bus communication velocity and I\/O density scaling preserve continuous data transfer across local expansion nodes without introducing timing skew. Photocouplers handle signal isolation between inputs and the internal NX bus, while transformers isolate power lines. Firmware flash compatibility ensures long-term operational consistency during controller software upgrades across deterministic networks.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"11\"\u003eOrdering Information\u003c\/h3\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e1 x Omron NX-TS2201 Temperature Input Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e1 x Screwless Clamping Terminal Block (16 terminals)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e1 x Installation Leaflet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"13\"\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003eMount the module securely onto a standard 35 mm DIN rail inside a protective industrial control enclosure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003eTerminate three-wire Pt100 or Pt1000 RTD leads directly into the 16-terminal screwless clamping block.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,2,0\"\u003eKeep conductor resistance below 20 ohm to restrict measurement distortion to 0.06 deg C\/ohm max.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,3,0\"\u003eObserve a mandatory 10-minute warm-up duration following power-up to stabilize internal reference circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"15\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul data-path-to-node=\"16\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,0,0\"\u003eQ: What sensor types are compatible with this resistance thermometer module?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,0,1\"\u003eA: The module supports three-wire Pt100 and three-wire Pt1000 resistance temperature detectors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,1,0\"\u003eQ: What is the signal conversion time per unit?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,1,1\"\u003eA: Signal conversion completes at a rate of 250 ms per unit under Free-Run refreshing mode.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,2,0\"\u003eQ: What is the maximum resolution achieved by the conversion circuitry?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,2,1\"\u003eA: The resolution is 0.1 deg C max. across supported RTD measuring ranges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,3,0\"\u003eQ: What excitation current is applied to the resistance thermometers?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,3,1\"\u003eA: The internal constant current source supplies an input detection current of approximately 0.25 mA.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,4,0\"\u003eQ: What is the upper limit for external conductor resistance?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,4,1\"\u003eA: Conductor resistance must not exceed 20 ohm to limit measurement error to 0.06 deg C\/ohm max.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,5,0\"\u003eQ: What warm-up period is required after applying power?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,5,1\"\u003eA: A minimum warm-up period of 10 minutes is required to stabilize internal compensation networks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,6,0\"\u003eQ: What isolation technology separates the field inputs from the internal bus?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,6,1\"\u003eA: Power is isolated via transformers while signal paths utilize photocouplers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,7,0\"\u003eQ: What is the net physical weight of the hardware module?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,7,1\"\u003eA: The module has a net physical weight of 0.07 Kg (70 grams).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306634330285,"sku":"NX-TS2201","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/nx-ts2201_2.jpg?v=1791645757","url":"https:\/\/www.maxwellplc.com\/products\/nx-ts2201-omron-nx-series-temperature-input-unit","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}