{"product_id":"nx-tc3408-omron-nx-series-temperature-control-unit","title":"NX-TC3408 Omron NX Series Temperature Control Unit","description":"\u003cp\u003eThe \u003cstrong\u003eOmron NX-TC3408\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eNX-TC3408\u003c\/strong\u003e Temperature Control Unit, operates as a dedicated hardware component for multi-loop thermal processing and proportional analog loop drive execution within the NX I\/O Bus system.\u003c\/p\u003e\n\u003ch3\u003eModel Nomenclature \u0026amp; Parameter Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNX: Modular Sysmac I\/O platform hardware classification\u003c\/li\u003e\n\u003cli\u003eTC: Dedicated temperature control module functional class\u003c\/li\u003e\n\u003cli\u003e3: 24 mm module housing width profile\u003c\/li\u003e\n\u003cli\u003e4: 4-loop temperature control capacity\u003c\/li\u003e\n\u003cli\u003e08: Universal thermocouple\/Pt100 inputs with 4 to 20 mA \/ 0 to 20 mA linear analog current outputs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications Summary\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNX-TC3408\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Unit Dimensions\u003c\/td\u003e\n\u003ctd\u003e24 mm x 100 mm x 80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e50 mm x 120 mm x 100 mm \u003ci\u003e(Shipping weight: 1.00 kg)\u003c\/i\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMax. 1.85 W (from NX bus power supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Analog Inputs\u003c\/td\u003e\n\u003ctd\u003e4 (Isolated temperature inputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Input Types\u003c\/td\u003e\n\u003ctd\u003eB, C, E, J, JPt100, K, L, N, P, Pt100, R, S, T, U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Analog Outputs\u003c\/td\u003e\n\u003ctd\u003e4 (0 to 20 mA, 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Resolution\u003c\/td\u003e\n\u003ctd\u003e14 Bit (1:10000 resolution scaling)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Time\u003c\/td\u003e\n\u003ctd\u003e50 ms\/unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Function\u003c\/td\u003e\n\u003ctd\u003eHeat or Cool control mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Connection Type\u003c\/td\u003e\n\u003ctd\u003eRemovable Push-in Plus terminal block (2 connectors)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Bus Updating \u0026amp; Flash Firmware Integration\u003c\/h3\u003e\n\u003cp\u003eThe unit provides 50 ms\/unit conversion speed to sustain precise PID temperature loops across processing channels. High-speed backplane synchronization maintains backplane bus communication velocity Licences during high-density I\/O density scaling routines across the NX bus coupler. Internal firmware flash compatibility ensures zero-drift analog signal processing during dynamic controller operations.\u003c\/p\u003e\n\u003ch3\u003eDelivery Package Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x NX-TC3408 Temperature Control Unit Base Module\u003c\/li\u003e\n\u003cli\u003e2 x Removable Push-in Plus Terminal Blocks\u003c\/li\u003e\n\u003cli\u003e1 x Terminal Wiring Map Label Sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePanel Installation \u0026amp; Field Wiring Directives\u003c\/h3\u003e\n\u003ch4\u003eMounting Configuration\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHook the upper mounting claw onto a standard 35 mm DIN rail and push the module flush into the adjacent NX I\/O bus unit until the side locks engage.\u003c\/li\u003e\n\u003cli\u003eMaintain a minimum vertical clearance of 30 mm above and below the housing to facilitate airflow and cable egress.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWiring \u0026amp; Insulation Guidelines\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eStrip solid or ferruled wires to 10 mm and insert directly into the Push-in Plus terminals without screw tools.\u003c\/li\u003e\n\u003cli\u003eUtilize shielded twisted-pair cables for thermocouple and RTD wiring, grounding the outer cable shields to a low-impedance functional earth ground bar.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Inquiry Resolutions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat temperature sensors are compatible with the input channels?\u003c\/p\u003e\n\u003cp\u003eChannels support thermocouples (B, C, E, J, K, L, N, P, R, S, T, U) and resistance thermometers (Pt100, JPt100).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat output signal types are provided for temperature control drives?\u003c\/p\u003e\n\u003cp\u003eThe unit provides 4 linear analog current outputs configurable for either 0 to 20 mA or 4 to 20 mA.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the loop update rate for the 4-channel temperature control?\u003c\/p\u003e\n\u003cp\u003eThe module features a high-speed conversion rate of 50 ms per unit across all 4 control loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAre individual temperature input channels galvanically isolated?\u003c\/p\u003e\n\u003cp\u003eYes, the input circuit architecture features channel-to-channel isolation to eliminate ground loop noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan terminal blocks be detached without disconnecting field wiring?\u003c\/p\u003e\n\u003cp\u003eYes, the module includes two removable Push-in Plus terminal connectors for rapid maintenance swap-outs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat resolution scaling is provided on the analog output stage?\u003c\/p\u003e\n\u003cp\u003eThe 14-bit D\/A conversion stage provides a fine output resolution ratio of 1:10000.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the unit require external power for internal logic?\u003c\/p\u003e\n\u003cp\u003eInternal circuit logic draws operation power directly from the NX bus power supply rail at 1.85 W max.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs hot-swapping permitted on the NX bus backplane?\u003c\/p\u003e\n\u003cp\u003eThe NX bus power supply must be completely switched off prior to installing or removing the unit module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306630660269,"sku":"NX-TC3408","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/nx-tc3408-1_3.jpg?v=1790391752","url":"https:\/\/www.maxwellplc.com\/products\/nx-tc3408-omron-nx-series-temperature-control-unit","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}