{"product_id":"nx-da3205-omron-nx-series-analog-i-o-unit","title":"NX-DA3205 Omron NX Series Analog I\/O Unit","description":"\u003ch1 data-path-to-node=\"0\"\u003eOmron NX-DA3205 Analog I\/O Unit NX Series\u003c\/h1\u003e\n\u003ch1 data-path-to-node=\"1\"\u003eNX-DA3205 Omron Analog I\/O Unit NX Series\u003c\/h1\u003e\n\u003ch1 data-path-to-node=\"2\"\u003eNX-DA3205 Omron NX Series Analog I\/O Unit\u003c\/h1\u003e\n\u003ch1 data-path-to-node=\"3\"\u003eOmron NX-DA3205 NX Series Analog I\/O Unit\u003c\/h1\u003e\n\u003cp data-path-to-node=\"4\"\u003eConfigured for high-speed current signal output in NX I\/O Bus architectures, the \u003cb data-path-to-node=\"4\" data-index-in-node=\"81\"\u003eOmron NX-DA3205\u003c\/b\u003e (\u003cb data-path-to-node=\"4\" data-index-in-node=\"98\"\u003eNX-DA3205\u003c\/b\u003e) Analog I\/O Unit provides direct physical\/electrical execution. It operates with a fast conversion rate of 0.04 ms per unit across 4 dedicated analog output channels. Utilizing Push-in Plus terminal connections, the module processes 4 to 20 mA linear output signals synchronously to ensure deterministic control timing without requiring analog inputs or specialized temperature sensing circuits.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"5\"\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eNX\u003c\/b\u003e: Product series designation for Omron modular I\/O system backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eDA\u003c\/b\u003e: Analog Output Unit classification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003e3\u003c\/b\u003e: 4-channel capacity per module interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003e2\u003c\/b\u003e: 1\/12000 high-resolution performance tier (15-bit representation).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\"\u003e\u003cb data-path-to-node=\"6,4,0\" data-index-in-node=\"0\"\u003e05\u003c\/b\u003e: Linear current range profile (4 to 20 mA range output).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"7\"\u003eHardware Parameters\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"8\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,1,0,0\"\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,1,1,0\"\u003eNX-DA3205\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,2,0,0\"\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,2,1,0\"\u003eOmron\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,3,0,0\"\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,3,1,0\"\u003eJapan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,4,0,0\"\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,4,1,0\"\u003e0.07 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,5,0,0\"\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,5,1,0\"\u003e1.2 cm x 7.1 cm x 10.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,6,0,0\"\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,6,1,0\"\u003e0 to 55 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,7,0,0\"\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,7,1,0\"\u003e1.45 W max (via NX bus supply)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,8,0,0\"\u003eModule Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,8,1,0\"\u003eAnalog Output Unit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,9,0,0\"\u003eNumber of Analog Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,9,1,0\"\u003e4 channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,10,0,0\"\u003eLinear Output Signal\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,10,1,0\"\u003e4 to 20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,11,0,0\"\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,11,1,0\"\u003e15 Bit (1\/12000 full scale)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,12,0,0\"\u003eConversion Speed\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,12,1,0\"\u003e0.04 ms\/unit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,13,0,0\"\u003eSignal Processing Mode\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,13,1,0\"\u003eSynchronous I\/O refreshing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,14,0,0\"\u003eTerminal Connection Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,14,1,0\"\u003ePush-in Plus (1 connector)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,15,0,0\"\u003eIP Protection Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,15,1,0\"\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-path-to-node=\"9\"\u003eDeterministic Bus Performance\u003c\/h3\u003e\n\u003cp data-path-to-node=\"10\"\u003eThe module leverages synchronous signal processing over the NX I\/O Bus to eliminate jitter during output signal updates. By coupling high-speed backplane bus communication velocity with a 0.04 ms update time per unit, output loops remain fully synchronized with EtherCAT master control cycles. Channel-to-channel signal propagation avoids timing skew, making the unit suitable for multi-axis or tight motion-servo feedback applications. Integrated firmware maintains output integrity and deterministic state execution during backplane refresh cycles.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"11\"\u003ePackage \u0026amp; Ordering Content\u003c\/h3\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e1 x Omron NX-DA3205 Analog Output Unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e1 x Push-in Plus Terminal Block (16-pin integrated)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e1 x Standard Hardware Installation Sheet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"13\"\u003eMechanical Mounting \u0026amp; Wire Setup\u003c\/h3\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eDIN Rail Fitting\u003c\/b\u003e: Engage the top rear notch of the module onto a standard 35 mm DIN rail, then press firmly until the locking lever clicks into place.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003ePush-in Wire Termination\u003c\/b\u003e: Strip solid or ferruled stranded wires to 10 mm. Insert directly into the Push-in terminal holes without tools.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,2,0\"\u003e\u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"0\"\u003eWire Extraction\u003c\/b\u003e: Press the release button using a flat-blade screwdriver while pulling the wire out straight.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,3,0\"\u003e\u003cb data-path-to-node=\"14,3,0\" data-index-in-node=\"0\"\u003eShielding \u0026amp; Grounding\u003c\/b\u003e: Ground the shield wire at the ground terminal of the NX bus setup to prevent electromagnetic interference on the 4-20 mA loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,4,0\"\u003e\u003cb data-path-to-node=\"14,4,0\" data-index-in-node=\"0\"\u003eWiring Separation\u003c\/b\u003e: Route output signal wires away from high-voltage power lines and motor drive cables in a separate conduit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"15\"\u003eFAQs\u003c\/h3\u003e\n\u003cul data-path-to-node=\"16\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,0,0\"\u003eIs the NX-DA3205 unit hot-swappable during active bus operation?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,0,1\"\u003eNo. You must turn off the power supply to the CPU unit, expansion unit, and the NX I\/O bus before installing or removing the module to prevent electrical damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,1,0\"\u003eWhat happens to the 4 to 20 mA outputs if backplane communication fails?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,1,1\"\u003eOutputs transition to a pre-configured fail-safe state (either holding last value or dropping to 0 mA \/ lower limit) according to the CPU configuration settings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,2,0\"\u003eDoes the module require an external power supply for loop current?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,2,1\"\u003eInternal circuits run on NX bus power, but external 24 VDC power must be wired to the I\/O power terminals to drive the 4 to 20 mA output loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,3,0\"\u003eWhat is the total conversion time when all 4 channels are enabled?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,3,1\"\u003eThe conversion time remains 0.04 ms per unit due to simultaneous internal sampling and synchronous refresh execution across channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,4,0\"\u003eWhat wire gauge sizes fit the Push-in Plus terminal block?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,4,1\"\u003eThe terminal block accepts solid or stranded cables with ferrules ranging from 0.25 mm2 to 1.5 mm2 (AWG 24 to 16).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,5,0\"\u003eCan this unit handle voltage output signals like 0 to 10 VDC?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,5,1\"\u003eNo. The NX-DA3205 is strictly hardwired for linear current signals in the 4 to 20 mA range and cannot generate voltage outputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,6,0\"\u003eHow does synchronous I\/O processing benefit the control system?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,6,1\"\u003eIt synchronizes analog output updates directly with the EtherCAT cycle time, eliminating timing variation between the controller and end devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,7,0\"\u003eDoes the NX-DA3205 provide channel-to-channel isolation?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,7,1\"\u003eNo. Isolation exists between the NX bus and the I\/O signals, but individual channels share a common ground reference internally.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306662674605,"sku":"NX-DA3205","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/NX-DA3205-1.jpg?v=1790227506","url":"https:\/\/www.maxwellplc.com\/products\/nx-da3205-omron-nx-series-analog-i-o-unit","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}