{"product_id":"nx-da2205-omron-nx-series-analog-output-unit","title":"NX-DA2205 Omron NX-series Analog Output Unit","description":"\u003cp\u003eThe \u003cstrong\u003eOmron NX-DA2205\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eNX-DA2205\u003c\/strong\u003e Analog Output Unit, operates as a dedicated hardware component for high-precision current conversion and signal actuation within distributed industrial control networks.\u003c\/p\u003e\n\u003ch3\u003eSuffix Nomenclature \u0026amp; Architecture Matrix\u003c\/h3\u003e\n\u003cp\u003eThe model designation defines structural channel capacity, output signal types, and internal conversion parameters within the Omron NX modular product line.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNX\u003c\/strong\u003e: Modular control system series optimized for high-speed backplane bus communication.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDA\u003c\/strong\u003e: Dedicated analog output module classification designed for current and voltage control loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2205\u003c\/strong\u003e: Two-channel analog output configuration featuring high-resolution 4 to 20 mA signal generation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNX-DA2205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.7 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e20 cm x 15 cm x 10 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.25 W max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e2 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Range\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Conversion Range\u003c\/td\u003e\n\u003ctd\u003e-5 to 105 percent (full scale)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAllowable Load Resistance\u003c\/td\u003e\n\u003ctd\u003e600 ohms min.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1\/30000 (full scale)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Communication Velocity \u0026amp; Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe module integrates directly with the central processing backplane via high-speed communication channels, supporting deterministic network topologies. Firmware flash compatibility ensures seamless system updates without interrupting active control signals. Furthermore, backplane bus communication velocity guarantees rapid data transfer from the controller CPU, while I\/O density scaling allows efficient system expansion across multiple modular nodes without sacrificing conversion precision.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron NX-DA2205 Analog Output Unit\u003c\/li\u003e\n\u003cli\u003e1 x 8-terminal screwless clamping terminal block\u003c\/li\u003e\n\u003cli\u003e1 x Hardware safety and installation manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnclosure Mounting \u0026amp; Field Wiring Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDIN Rail Mounting\n\u003cul\u003e\n\u003cli\u003eSecure the unit onto a standard 35 mm DIN rail inside a protective metallic enclosure designed for industrial control environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSignal Shielding\n\u003cul\u003e\n\u003cli\u003eRoute shielded twisted-pair cables to the output terminals to prevent electromagnetic interference along current loops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eTerminal Connection\n\u003cul\u003e\n\u003cli\u003eInsert stripped conductor wires directly into the 8-terminal screwless clamping block without utilizing screw-tightening tools.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eLoad Resistance Compliance\n\u003cul\u003e\n\u003cli\u003eEnsure external load resistance connected to output channels is maintained at 600 ohms minimum to prevent signal clipping.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Operation Frequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat output signal range does the NX-DA2205 support?\u003c\/p\u003e\n\u003cp\u003eThe unit delivers a standard industrial current output ranging from 4 to 20 mA across its channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum resolution of the analog conversion?\u003c\/p\u003e\n\u003cp\u003eThe module achieves a high-resolution output of 1\/30000 across the full scale range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many output points are housed on this hardware module?\u003c\/p\u003e\n\u003cp\u003eThe module features two independent analog output channels with dedicated terminal connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat allowable load resistance must be maintained on output loops?\u003c\/p\u003e\n\u003cp\u003eExternal load resistance connected to the output terminals must be 600 ohms minimum.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhich I\/O refreshing methods are supported by the unit?\u003c\/p\u003e\n\u003cp\u003eThe module supports selectable Synchronous I\/O refreshing or Free-Run refreshing modes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the conversion range percentage limits?\u003c\/p\u003e\n\u003cp\u003eThe output conversion range extends from -5 to 105 percent of full scale.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the net weight of the standalone hardware?\u003c\/p\u003e\n\u003cp\u003eThe standalone unit weighs 0.7 Kg, with a packaged shipping weight of 2 Kg.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat terminal block configuration is provided on the front panel?\u003c\/p\u003e\n\u003cp\u003eIt features a screwless clamping terminal block comprising 8 individual terminal points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306636755117,"sku":"NX-DA2205","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/nx-da2205_1.jpg?v=1791554616","url":"https:\/\/www.maxwellplc.com\/products\/nx-da2205-omron-nx-series-analog-output-unit","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}