{"product_id":"nx-ad3204-omron-analog-i-o-unit-nx-series","title":"NX-AD3204 Omron Analog I\/O Unit NX-series","description":"\u003cp\u003eConfigured for high-speed differential analog voltage or current conversion in industrial network architectures, the \u003cstrong\u003eOmron NX-AD3204\u003c\/strong\u003e (\u003cstrong\u003eNX-AD3204\u003c\/strong\u003e Analog I\/O Unit) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eDesignation Breakdown \u0026amp; Model Structure\u003c\/h3\u003e\n\u003cp\u003eThe product code reveals precise internal hardware architecture and input point configurations defined within the Omron NX modular ecosystem.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNX\u003c\/strong\u003e: Modular control system series optimized for EtherCAT and EtherNet\/IP bus integration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAD\u003c\/strong\u003e: Analog input module category handling continuous electrical signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3204\u003c\/strong\u003e: Four-channel high-resolution differential signal conversion configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNX-AD3204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e120 g max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e100 mm x 50 mm x 80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.10 W max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of points\u003c\/td\u003e\n\u003ctd\u003e4 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O range\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1\/8000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion time\u003c\/td\u003e\n\u003ctd\u003e250 us per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus \u0026amp; Network Communication Performance\u003c\/h3\u003e\n\u003cp\u003eThe hardware interfaces directly with the central processing backplane via high-speed communication channels, supporting deterministic network topologies. Firmware flash compatibility ensures seamless system upgrades without interrupting communication packets. Furthermore, backplane bus communication velocity guarantees rapid data transfer to the controller CPU, while I\/O density scaling allows efficient system expansion across multiple modular nodes without sacrificing sampling throughput.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron NX-AD3204 Analog I\/O Unit\u003c\/li\u003e\n\u003cli\u003e1 x Push-in terminal block connector\u003c\/li\u003e\n\u003cli\u003e1 x Safety and installation manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Mount and Wiring Protocols\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDIN Rail Attachment\n\u003cul\u003e\n\u003cli\u003eMount the unit horizontally onto a standard 35 mm DIN rail inside an IP54-rated control enclosure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSignal Shielding\n\u003cul\u003e\n\u003cli\u003eTerminate analog signal cable shields securely at the designated grounding bar to minimize electromagnetic susceptibility.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eConductor Insertion\n\u003cul\u003e\n\u003cli\u003eStrip insulation from input wires to the specified length and insert them into the spring-loaded push-in terminals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermal Management\n\u003cul\u003e\n\u003cli\u003eMaintain adequate vertical clearance above and below the module to facilitate natural convection cooling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOperational Inquiry and Maintenance FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat input range does the NX-AD3204 support?\u003c\/p\u003e\n\u003cp\u003eThe unit processes analog signals within the 4 to 20 mA range using a differential input architecture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow fast is the channel conversion cycle?\u003c\/p\u003e\n\u003cp\u003eThe analog-to-digital conversion executes at a rate of 250 us per point across all active channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the native resolution of the input channels?\u003c\/p\u003e\n\u003cp\u003eConversion data is output at a resolution of 1\/8000 across the full scale range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many input points are available on this card?\u003c\/p\u003e\n\u003cp\u003eThe module provides four distinct differential analog input channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the unit require a separate power supply connection?\u003c\/p\u003e\n\u003cp\u003eOperating power is drawn directly from the connected NX bus backplane power supply.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum power consumption rating?\u003c\/p\u003e\n\u003cp\u003ePower consumption does not exceed 1.10 W during normal operating conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should signal lines be protected against noise?\u003c\/p\u003e\n\u003cp\u003eAlways use twisted-pair shielded cables and ground the shield properly at the enclosure entry point.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the allowable operating temperature span?\u003c\/p\u003e\n\u003cp\u003eThe internal cabinet temperature must remain within the 0 deg C to 55 deg C operational boundary.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306642227373,"sku":"NX-AD3204","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/nx-ad3204_1.jpg?v=1791554069","url":"https:\/\/www.maxwellplc.com\/products\/nx-ad3204-omron-analog-i-o-unit-nx-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}