{"product_id":"ns5-sq01b-v2-omron-interactive-display-panel-ns-series","title":"NS5-SQ01B-V2 Omron Interactive Display Panel NS Series","description":"\u003cp\u003eThe \u003cstrong\u003eOmron NS5-SQ01B-V2\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eNS5-SQ01B\u003c\/strong\u003e Interactive Display Panel, operates as a dedicated hardware component for real-time visualization and parameter modification within Omron PLC networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Designation Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNS5\u003c\/strong\u003e: Represents the 5.7 inch screen diagonal display chassis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eS\u003c\/strong\u003e: Standard high-resolution TFT color display architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Indicates Quarter Video Graphics Array screen matrix (320 x 240 pixels).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e01\u003c\/strong\u003e: Serial communication configuration via dual RS-232C channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eB\u003c\/strong\u003e: Black bezel case color option.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eV2\u003c\/strong\u003e: Version 2 hardware revision supporting optimized screen transfer protocols.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Technical Parameters\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNS5-SQ01B-V2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e5.4 cm x 19.5 cm x 14.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e24 VDC (20.4 to 27.6 VDC allowable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e15 W max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBezel Color\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eTFT Color LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e5 years at 25 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Environment\u003c\/td\u003e\n\u003ctd\u003e0 to 50 deg C, non-corrosive gases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eController Interfaces and Firmware Synchronization\u003c\/h3\u003e\n\u003cp\u003eThe terminal processes cyclic communication over serial links to maintain predictable backplane bus communication velocity across connected network nodes. Internal flash memory ensures complete firmware flash compatibility, preventing execution latency during complex graphic page transitions or high I\/O density scaling. Network status flags register hardware updates via deterministic host-link frame timing.\u003c\/p\u003e\n\u003ch3\u003ePackage Component List\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x NS5-SQ01B-V2 Terminal Assembly\u003c\/li\u003e\n\u003cli\u003e4 x Panel Mounting Brackets\u003c\/li\u003e\n\u003cli\u003e1 x 3-pin DC Power Input Terminal Block Connector\u003c\/li\u003e\n\u003cli\u003e1 x Installed Rear Lithium Battery\u003c\/li\u003e\n\u003cli\u003e1 x Panel Waterproof Sealing Gasket\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Mounting and Wiring Protocol\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCut the panel enclosure opening strictly to 184 mm width by 131 mm height.\u003c\/li\u003e\n\u003cli\u003eInspect the perimeter synthetic rubber gasket to ensure complete insertion in the front bezel channel prior to panel installation.\u003c\/li\u003e\n\u003cli\u003eSecure the four mounting brackets around the chassis rim, tightening each screw to a torque between 0.5 N m and 0.6 N m.\u003c\/li\u003e\n\u003cli\u003eConnect the 24 VDC power conductors using AWG 14 to AWG 22 copper wiring to the provided 3-pin connector terminal.\u003c\/li\u003e\n\u003cli\u003eEnsure a minimum clearance distance of 100 mm on all rear sides to allow unhindered passive thermal convection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Support FAQs\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the procedure for replacing the backup battery without losing memory?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Apply 24 VDC power to the terminal for at least 5 minutes, turn off power, and replace the battery within 5 minutes to prevent SRAM data loss.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How is the RS-232C serial port shield grounded correctly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Connect the cable shield braid to the shell of the DB9 connector on the terminal side and ground the FG terminal to a Class D earth ground.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What causes the screen backlight to automatically switch off during operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The internal backlight saver timer automatically disables the LCD illumination after a user-configured period of touch inactivity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the serial communication baud rate be modified via software?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Serial communication parameters including baud rate, parity, and stop bits are configured via the system menu or CX-Designer software setup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What environment constraints apply to the operating location?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The unit must be installed in an environment free of corrosive gases, conductive dust, direct sunlight, and excessive ambient vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the panel support external alarm logging onto a memory card?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Event logs, alarm history, and historical trend data can be saved to a CompactFlash card inserted in the rear memory card slot.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do I enter the internal System Menu on startup?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Touch two opposing corners of the display panel simultaneously during power-up or runtime to invoke the system diagnostic screen.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What cable length limits apply to the RS-232C communication lines?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The total cable length for RS-232C point-to-point connections must not exceed 15 m to prevent signal degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306654515373,"sku":"NS5-SQ01B-V2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/NS-3.jpg?v=1790141007","url":"https:\/\/www.maxwellplc.com\/products\/ns5-sq01b-v2-omron-interactive-display-panel-ns-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}