{"product_id":"ns5-sq00b-ecv2-omron-ns-series-interactive-display-panel","title":"NS5-SQ00B-ECV2 Omron NS Series Interactive Display Panel","description":"\u003cp\u003eThe \u003cstrong\u003eOmron NS5-SQ00B-ECV2\u003c\/strong\u003e serves as the primary \u003cstrong\u003eNS5-SQ00\u003c\/strong\u003e Interactive Display Panel utilized to execute direct operator interface visualization and real-time register monitoring across SYSMAC PLC platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Nomenclature and Variant Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNS5\u003c\/strong\u003e: Defines the 5.7 inch display housing geometry and mounting foot pattern.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eS\u003c\/strong\u003e: Identifies high-contrast STN monochrome\/color LCD panel technology.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Represents standard QVGA resolution matrix layout (320 x 240 pixels).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e00\u003c\/strong\u003e: Specifies baseline dual RS-232C serial communication ports without Ethernet expansion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eB\u003c\/strong\u003e: Designates black outer bezel enclosure molding.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECV2\u003c\/strong\u003e: Enhanced hardware revision variant providing expanded system memory and updated macro script handling routines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical and Electrical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNS5-SQ00B-ECV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e19.5 cm x 14.2 cm x 5.4 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e15 W max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e5 years at 25 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Environment\u003c\/td\u003e\n\u003ctd\u003eNon-corrosive gas atmosphere\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Communications and Memory Architecture\u003c\/h3\u003e\n\u003cp\u003eThe panel coordinates cyclic serial polling over dedicated serial lines to maintain optimum backplane bus communication velocity across connected controller stations. Non-volatile internal memory structures preserve complete firmware flash compatibility, preventing execution frame display latency during rapid memory bit operations and high I\/O density scaling routines.\u003c\/p\u003e\n\u003ch3\u003ePackage Component List\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x NS5-SQ00B-ECV2 Interactive Display Panel Unit\u003c\/li\u003e\n\u003cli\u003e4 x Enclosure Mounting Brackets\u003c\/li\u003e\n\u003cli\u003e1 x Removable 3-Pin Power Supply Terminal Block\u003c\/li\u003e\n\u003cli\u003e1 x Synthetic Rubber Bezel Sealing Gasket\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Mounting and Wiring Protocols\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePrepare panel cutout opening measuring exactly 184 mm horizontal by 131 mm vertical.\u003c\/li\u003e\n\u003cli\u003eVerify synthetic gasket fit within outer bezel perimeter channel to maintain IP65 front seal rating.\u003c\/li\u003e\n\u003cli\u003eSeat panel into opening and tighten 4 mounting bracket screws to a torque range of 0.5 N m to 0.6 N m.\u003c\/li\u003e\n\u003cli\u003eLand AWG 14 to AWG 22 power conductors onto the removable 3-pin connector block observing correct DC polarity.\u003c\/li\u003e\n\u003cli\u003eMaintain minimum 100 mm rear panel depth clearance to allow free thermal convection flow through housing vents.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Maintenance FAQs\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the nominal operational service life of the internal backup battery?\u003c\/p\u003e\n\u003cp\u003eThe internal lithium backup battery provides a continuous retention life of 5 years under standard 25 deg C ambient operating conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhich serial communication protocols are natively supported over the DB9 interfaces?\u003c\/p\u003e\n\u003cp\u003eThe dual RS-232C ports execute Omron Host Link, 1:N NT Link, and high-speed 1:1 NT Link serial communication protocols.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat environmental operating constraints apply to the installation site atmosphere?\u003c\/p\u003e\n\u003cp\u003eThe unit must operate in an environment entirely free of corrosive gases, conductive dust, and volatile organic solvents.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are project files transferred to the terminal without an onboard Ethernet controller?\u003c\/p\u003e\n\u003cp\u003eApplication programs and system memory images are uploaded using an RS-232C host cable or via a CompactFlash card inserted into the rear expansion slot.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat supply voltage variation is permitted on the nominal 24 VDC power input?\u003c\/p\u003e\n\u003cp\u003eThe internal power supply accepts an operational DC voltage range spanning from 20.4 VDC up to 27.6 VDC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat grounding connection method mitigates electrical interference on communication lines?\u003c\/p\u003e\n\u003cp\u003eConnect the functional ground terminal block pin directly to a Class D dedicated earth ground using short AWG 14 conductor wire.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the panel hardware system menu invoked during device power-up?\u003c\/p\u003e\n\u003cp\u003eTouch two opposing corners of the display matrix simultaneously during initialization to access system diagnostic parameters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the front touch surface meet industrial enclosure protection requirements?\u003c\/p\u003e\n\u003cp\u003eThe installed front bezel and touch membrane conform to IP65 water-tight and dust-tight protection specifications when properly gasketed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306655203501,"sku":"NS5-SQ00B-ECV2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/NS-3.jpg?v=1790141007","url":"https:\/\/www.maxwellplc.com\/products\/ns5-sq00b-ecv2-omron-ns-series-interactive-display-panel","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}