{"product_id":"nktt01-10-abb-bailey-infi-90-termination-cable","title":"NKTT01-10 ABB Bailey Infi 90 Termination Cable","description":"\u003cp\u003eThe \u003cstrong\u003eABB NKTT01-10\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eNKTT01\u003c\/strong\u003e termination cable, provides a physical termination interface for signal conductors within ABB Bailey Infi 90 hardware connections. The assembly is specified as a 10 ft cable with an integrated 75 ohm terminator.\u003c\/p\u003e\n\u003ch3\u003eModel and Configuration\u003c\/h3\u003e\n\u003cp\u003eThe NKTT01-10 designation identifies the NKTT01 cable assembly with the -10 length variant. The supplied data specifies a 10 ft cable configuration and a 75 ohm termination element.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNKTT01-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eBailey Infi 90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTermination Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e25.4 x 2.5 x 25.4 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e10 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e300 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e3-5 A per conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminator\u003c\/td\u003e\n\u003ctd\u003e75 ohm +\/- 1%, 0.25 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +80 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5-95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified; passive cable assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipment Location\u003c\/td\u003e\n\u003ctd\u003eXiamen, China\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control Interface Characteristics\u003c\/h3\u003e\n\u003cp\u003eFor ABB industrial control installations, termination components affect the electrical behavior of connected signal conductors. The NKTT01-10 incorporates a specified 75 ohm termination element rated at 0.25 W. The termination resistance should remain matched to the intended Infi 90 circuit and should not be substituted with a different resistance value without confirming the system wiring specification.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x ABB NKTT01-10 Termination Cable\u003c\/li\u003e\n\u003cli\u003e1 x Integrated 75 ohm termination element\u003c\/li\u003e\n\u003cli\u003e1 x Cable assembly, 10 ft configuration\u003c\/li\u003e\n\u003cli\u003eNo separate power supply or electronic control module is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCable Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRoute the termination cable separately from high-voltage switching conductors where practical.\u003c\/li\u003e\n\u003cli\u003eAvoid sharp bends, crushing, or excessive mechanical tension on the cable assembly.\u003c\/li\u003e\n\u003cli\u003eMaintain conductor insulation and connector integrity during installation.\u003c\/li\u003e\n\u003cli\u003eUse the specified termination point for the intended Infi 90 circuit.\u003c\/li\u003e\n\u003cli\u003eDo not replace the 75 ohm termination element with an unverified resistance value.\u003c\/li\u003e\n\u003cli\u003eKeep cable routing away from strong electromagnetic interference sources where system wiring practice requires it.\u003c\/li\u003e\n\u003cli\u003eVerify continuity and termination resistance before energizing the associated circuit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the ABB NKTT01-10?\u003c\/strong\u003e\u003cbr\u003eIt is a Bailey Infi 90 termination cable assembly incorporating a specified 75 ohm termination element.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the cable length?\u003c\/strong\u003e\u003cbr\u003eThe supplied specification identifies the NKTT01-10 as a 10 ft cable configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat termination resistance is specified?\u003c\/strong\u003e\u003cbr\u003eThe integrated terminator is specified as 75 ohm with a tolerance of +\/- 1% and a 0.25 W rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat voltage is the cable rated for?\u003c\/strong\u003e\u003cbr\u003eThe specified voltage rating is 300 V AC\/DC. Installation should remain within the applicable circuit and wiring requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat current can each conductor carry?\u003c\/strong\u003e\u003cbr\u003eThe supplied specification gives a conductor current rating of 3-5 A. Actual circuit loading must remain within system wiring limits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the operating temperature range?\u003c\/strong\u003e\u003cbr\u003eThe specified operating range is -20 to +80 deg C with 5-95% RH non-condensing humidity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs NKTT01-10 an electronic module?\u003c\/strong\u003e\u003cbr\u003eNo. It is identified as a termination cable assembly. No electronic processing or independent power consumption is specified.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan the 75 ohm terminator be replaced with another value?\u003c\/strong\u003e\u003cbr\u003eIt should not be changed without confirming the associated Infi 90 circuit requirements, because termination resistance affects signal-line electrical characteristics.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021106237613,"sku":"NKTT01-10","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb-nktu01-20-bailey-infi-90-termination-unit-cable-thpcndfjftc.jpg?v=1766983401","url":"https:\/\/www.maxwellplc.com\/products\/nktt01-10-abb-bailey-infi-90-termination-cable","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}