{"product_id":"nkls11-10-abb-loop-interface-termination-cable","title":"NKLS11-10 ABB Loop Interface Termination Cable","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB NKLS11-10\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNKLS11-10\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTermination Interconnects, operates as a dedicated hardware component for signal transmission within ABB Distributed Control System (DCS) architectures. Configured for high-integrity connectivity in automation cabinets, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB NKLS11-10\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eNKLS11-10\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTermination Interconnects) provides direct physical signal bridging between termination units and controller interfaces. The cable assembly ensures deterministic data flow for analog and digital process loops, utilizing a hardened physical layer to maintain signal precision across the specified 10-foot span.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data Overview\u003c\/h3\u003e\n\u003cp\u003eThe NKLS11-10 is defined as a fixed-length cable assembly. There are no variants or modular matrix configurations applicable to this specific part number; it is supplied as a complete, pre-terminated interconnect solution intended for standard S800 or Advant DCS termination unit interfaces.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNKLS11-10\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSweden\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.6 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e33 x 7.6 x 33 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 to 80 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Applicable (Passive Cable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e22 AWG Loop Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e300 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt;= 20 Ohm\/km\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCommunication \u0026amp; Backplane Integration\u003c\/h3\u003e\n\u003cp\u003eThe NKLS11-10 is optimized for integration with ABB industrial control platforms. It supports deterministic network performance by maintaining low impedance pathways, which prevents signal attenuation in high-density backplane communication environments. When utilized within the S800 I\/O or Advant OCS ecosystems, the cable assembly acts as a physical extension of the termination unit, maintaining consistency with the deterministic bus communication velocity required by the system. The insulation properties and conductor shielding are verified for use in cabinets where high-speed I\/O density scaling and standard firmware communication protocols are active.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eNKLS11-10 Loop Interface Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePre-terminated connector housings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStandard factory-sealed protective bag\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCable tie and strain relief hardware\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRouting: Install the cable assembly in dedicated signal trays. Maintain a minimum separation of 15 cm from high-voltage AC power cabling to prevent electromagnetic coupling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShielding: Ensure the cable shielding is continuous and bonded to the cabinet functional earth point if required by the specific termination unit grounding scheme.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBending Radius: Adhere to the manufacturer-specified minimum bending radius to prevent insulation stress or conductor fatigue at the connector junctions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnection: Verify the physical alignment of the connector pins before insertion. Do not force the housing if resistance is felt; check for debris or pin deformation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnvironmental: Ensure the cable is protected from direct chemical contact and excessive UV exposure if installed in non-standard industrial enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is this cable hot-swappable?\u003c\/p\u003e\n\u003cp\u003eA: As a passive cable assembly, it does not support active hot-swapping; power should be isolated from the associated termination unit before disconnecting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does this cable affect backplane power load?\u003c\/p\u003e\n\u003cp\u003eA: No, the NKLS11-10 is a passive interconnect and does not consume power or affect the backplane power budget.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is there a redundancy switching delay?\u003c\/p\u003e\n\u003cp\u003eA: The cable does not govern redundancy; switching delays are managed by the host DCS controller and I\/O module configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is this cable compatible with all ABB DCS firmware versions?\u003c\/p\u003e\n\u003cp\u003eA: The physical cable is compatible with all systems utilizing the relevant interface; it does not contain firmware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the cable provide signal isolation?\u003c\/p\u003e\n\u003cp\u003eA: The cable provides physical shielding to minimize EMI, but galvanic isolation is determined by the termination unit and I\/O module electronics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Are there limitations on the field wiring length?\u003c\/p\u003e\n\u003cp\u003eA: The NKLS11-10 is a fixed 10-foot assembly. Extending this length may affect signal integrity for low-voltage analog loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can the cable be used in outdoor cabinets?\u003c\/p\u003e\n\u003cp\u003eA: It is rated for -20 to 80 deg C, but it must be housed in an enclosure that provides protection against weather and excessive UV.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the purpose of the 22 AWG conductor rating?\u003c\/p\u003e\n\u003cp\u003eA: This gauge is selected to provide a balance between mechanical durability and sufficient current-carrying capacity for 24 V DC logic and 4-20 mA signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45231157739693,"sku":"NKLS11-10","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb-nkls11-10-loop-interface-cable-wpdlroigtyz_278942bd-50ce-4c80-9330-bb984b4434c7.jpg?v=1762942160","url":"https:\/\/www.maxwellplc.com\/products\/nkls11-10-abb-loop-interface-termination-cable","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}