{"product_id":"nkcl01-10-abb-bailey-infi-90-coaxial-cable","title":"NKCL01-10 ABB Bailey Infi 90 Coaxial Cable","description":"\u003cp\u003eThe \u003cstrong\u003eABB NKCL01-10\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eNKCL01\u003c\/strong\u003e Coaxial Cable, operates as a dedicated hardware component for high-speed plant signal transmission and node interconnectivity within Bailey Infi 90 RIO\/Infi-Net communications. This 10 ft coaxial cable maintains steady 75 ohm line impedance across remote I\/O links, preventing waveform reflection and high-frequency data corruption during continuous node-to-node telemetry exchanges.\u003c\/p\u003e\n\u003ch3\u003eCable Assembly Variants \u0026amp; Dimensional Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNKCL01\u003c\/strong\u003e: Base factory designator for Infi 90 network coaxial communication cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-10\u003c\/strong\u003e: Physical length specifier designating a 10 foot (3.05 m) pre-terminated cable assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInner Conductor\u003c\/strong\u003e: 20 AWG solid core conductor providing low-resistance RF signal propagation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical \u0026amp; Environmental Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNKCL01-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSWEDEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e2.5 x 2.5 x 2.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +80 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive cable (0 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Gauge\u003c\/td\u003e\n\u003ctd\u003e20 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharacteristic Impedance\u003c\/td\u003e\n\u003ctd\u003e75 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVelocity of Propagation\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5-95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Telemetry \u0026amp; Flash Integrity\u003c\/h3\u003e\n\u003cp\u003eThe NKCL01-10 cable assembly stabilizes backplane bus communication velocity and high-speed RIO network throughput by maintaining an 80% velocity of propagation. The 75 ohm matched impedance structure suppresses standing waves across Infi-Net communication loops, ensuring zero-loss packet transfer between distributed processing units. This physical layer stability prevents communication timeout resets, protecting firmware flash compatibility across active node interface cards during online system operations.\u003c\/p\u003e\n\u003ch3\u003eStandard Shipping Package \u0026amp; Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x ABB NKCL01-10 Coaxial Cable Assembly (10 ft length)\u003c\/li\u003e\n\u003cli\u003eProtective connector end caps and sealed polybag packaging\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCable Installation \u0026amp; Route Management Rules\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatic Bend Radius\u003c\/strong\u003e: Maintain a minimum bend radius of 65 mm along the entire cable run to avoid pinching the dielectric core and altering line impedance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Distance\u003c\/strong\u003e: Lay coaxial runs at least 300 mm away from 480 VAC power cables, motor leads, and variable frequency drive outputs to eliminate induced EMI noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Engagement\u003c\/strong\u003e: Hand-tighten coaxial BNC\/F-type locking collars completely to ensure low-resistance shield contact and prevent signal intermissions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical Pulling Tension\u003c\/strong\u003e: Do not exceed a maximum pulling tension of 18 kg (40 lbs) during conduit pulls to preserve inner 20 AWG conductor integrity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering FAQ \u0026amp; Physical Limits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the nominal characteristic impedance of the NKCL01-10 cable assembly?\u003c\/p\u003e\n\u003cp\u003eThe cable maintains a 75 ohm nominal impedance to match standard Bailey Infi-Net line termination specs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the 10 ft cable length be cut and re-terminated in the field?\u003c\/p\u003e\n\u003cp\u003eField cutting is not recommended; altering length disrupts factory velocity factor tuning and attenuation calibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat voltage isolation rating does the outer jacket insulation provide?\u003c\/p\u003e\n\u003cp\u003eThe dielectric and jacket construction is rated for continuous dielectric withstand up to 500 V AC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the 80% velocity of propagation affect data timing?\u003c\/p\u003e\n\u003cp\u003eIt allows signals to travel at 80% of light speed, minimizing delay across RIO node communication loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes disconnecting this cable interrupt node bus communication?\u003c\/p\u003e\n\u003cp\u003eYes, removing an active cable breaks the physical loop, causing communication timeouts on connected nodes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat wire gauge size is used for the center signal conductor?\u003c\/p\u003e\n\u003cp\u003eThe central signal path utilizes a solid 20 AWG conductor for optimal high-frequency conductivity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should spare cable slack be coiled inside marshalling cabinets?\u003c\/p\u003e\n\u003cp\u003eLoop extra cable in loose circles no smaller than 150 mm in diameter; avoid sharp right-angle bends.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this coaxial cable be submerged or exposed to standing water?\u003c\/p\u003e\n\u003cp\u003eNo, the cable is designed for dry industrial environments within 5-95% RH non-condensing limits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021105647789,"sku":"NKCL01-10","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/NKCL01-7.jpg?v=1789278009","url":"https:\/\/www.maxwellplc.com\/products\/nkcl01-10-abb-bailey-infi-90-coaxial-cable","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}