{"product_id":"nfai143-h50-yokogawa-16-channel-4-20ma-analog-input-module","title":"NFAI143-H50 Yokogawa 16-Channel 4-20mA Analog Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Yokogawa NFAI143-H50 serves as a critical interface component within the CENTUM VP and ProSafe-RS control architectures. This high-density analog input module is engineered to receive and process standard 4 to 20 mA DC signals from field transmitters with precision. By providing high-level electrical isolation between the field instrumentation and the system bus, it safeguards the integrity of the control logic against electrical noise and potential surges. The module's architecture is optimized for high-speed data acquisition, ensuring that real-time process variables are updated with minimal latency for sensitive industrial loops.\u003c\/p\u003e\n\u003ch3\u003eAdvanced Hardware Parameters\u003c\/h3\u003e\n\u003cp\u003eThe following specifications detail the physical and electrical profile of the NFAI143-H50 module.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 isolated channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Signal Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 to 20 mA DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAllowable Input Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 mA maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±0.1% of full scale\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUpdate Cycle\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 milliseconds\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eExternal Supply Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24.0 V to 25.5 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Current Draw\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e230 mA (5 V DC) \/ 540 mA (24 V DC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDielectric Strength\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1500 V AC for 1 minute (Input to System)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperature Stability\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMax ±0.01% per °C drift\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 degrees Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Mass\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.3 kg (300g)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (Approx)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e130 mm x 130 mm x 40 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eStrategic Industrial Deployment\u003c\/h3\u003e\n\u003cp\u003eThe NFAI143-H50 is designed for environments where continuous process monitoring is mandatory. Its robust 16-channel isolation makes it particularly suitable for the following sectors:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOil and Gas Refining\u003c\/strong\u003e: Monitoring pressure, flow, and level transmitters across expansive facility footprints where ground loops could interfere with signal accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChemical Processing\u003c\/strong\u003e: Handling critical temperature and concentration data where high-speed updates (10ms) are required for safety-instrumented functions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Generation\u003c\/strong\u003e: Integrating feedback from boiler and turbine sensors into the distributed control system (DCS) for efficient load management.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWater and Wastewater\u003c\/strong\u003e: Reliable acquisition of remote telemetry data in outdoor environments prone to atmospheric interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the NFAI143-H50 provide power to the field transmitters?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: This module is primarily designed as a current input receiver. Depending on the baseplate configuration and wiring, external power or the system's 24V supply may be required to drive the 4-20mA loops.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the module handle signal spikes or overcurrent conditions?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The unit features built-in overcurrent protection and is rated for a maximum allowable input of 24 mA. Additionally, it offers 1500 V AC isolation to prevent field faults from damaging the system backplane.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this module compatible with the CENTUM VP series?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, the NFAI143-H50 is a standard component within the FIO (Field network I\/O) family used extensively in Yokogawa CENTUM VP and ProSafe-RS systems.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How often does the module refresh the data sent to the controller?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module operates on a high-speed data update cycle of 10 milliseconds, making it suitable for fast-acting control loops and transient monitoring.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":45878857171117,"sku":"NFAI143-H50","price":1999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/NFAI143-H50-1.jpg?v=1775094964","url":"https:\/\/www.maxwellplc.com\/products\/nfai143-h50-yokogawa-16-channel-4-20ma-analog-input-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}