{"product_id":"mc-paih03-honeywell-51304754-176-high-level-analog-input-module","title":"MC-PAIH03 Honeywell 51304754-176 High-Level Analog Input Module","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe Honeywell MC-PAIH03 (Part Number 51304754-176) is a high-density,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e16-channel analog input processor engineered for the legacy Universal Control Network (UCN) within the Experion and TDC 3000 ecosystems.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis \"High-Level\" module is specifically designed to interface with powered industrial transmitters,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eproviding a high-integrity gateway for translating field-side analog signals into digital data for the controller.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eEquipped with 16 differential input channels,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe MC-PAIH03 excels at maintaining signal purity in electrically noisy environments.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe module features a high-resolution 16-bit analog-to-digital (A\/D) converter and advanced noise filtering to ensure that critical process variables are recorded with clinical accuracy.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eTo ensure longevity in corrosive or humid industrial atmospheres,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe PCB is protected by a professional-grade conformal coating,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emeeting G3 harsh environment standards.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eKey Hardware Parameters\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe MC-PAIH03 is defined by its superior rejection of electrical interference and its broad compatibility with standard Field Termination Assemblies (FTAs).\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eChannel Configuration\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e16 Differential Analog Inputs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInput Range Support\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e1-5 VDC,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0-5 VDC,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e4-2 VDC,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand 4-20 mA (utilizing a standard 250Ω precision resistor)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eConversion Precision\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e16-bit A\/D resolution\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eNoise Suppression\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e70 dB common-mode rejection and 32 dB normal-mode rejection (at 60 Hz)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInput Impedance\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSuperior \u0026gt;10 MΩ to prevent signal loading\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCrosstalk Protection\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e60 dB channel-to-channel rejection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eEnvironmental Protection\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eConformal coated electronics for chemical\/moisture resistance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eFTA Compatibility\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFully supports MU-TAIH02,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eTAIH12,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand TAIH53 termination assemblies\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eWeight\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e4 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDimensions\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e7 x 14 x 14.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eManufacturing Origin\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUSA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe robust signal acquisition capabilities of the MC-PAIH03 make it a vital component in sectors requiring high-reliability monitoring:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePetrochemical Refining\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eMonitoring sensitive pressure and temperature transmitters in explosive zones via isolated differential inputs.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eChemical Processing\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eTracking flow rates and vessel levels where signal accuracy directly impacts batch quality and chemical dosing precision.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePower Generation\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eInterfacing with turbine telemetry and boiler sensors where high noise immunity is required due to proximity to heavy electrical machinery.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eLegacy System Maintenance\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eServing as a critical replacement part for aging TDC 3000 or Experion UCN architectures to extend the service life of existing control infrastructure.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eWater and Wastewater\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eCentralizing data from distributed flow meters and analytical sensors over long field cable runs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45518952431789,"sku":"51304754-176","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/honeywell-mc-paih03-51304754-176-analog-input-module-nebk0krsunj.jpg?v=1766982810","url":"https:\/\/www.maxwellplc.com\/products\/mc-paih03-honeywell-51304754-176-high-level-analog-input-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}