{"product_id":"kj3001x1-bh1-12p0558x152-emerson-isolated-card-deltav-sis-series","title":"KJ3001X1-BH1 12P0558X152 Emerson Isolated Card DeltaV SIS Series","description":"\u003cp\u003eConfigured for signal isolation in DeltaV SIS process safety environments, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEmerson KJ3001X1-BH1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eKJ3001X1-BH1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e12P0558X152) Isolated Card provides direct physical\/electrical execution of galvanic barrier isolation for field instrumentation loops.\u003c\/p\u003e\n\u003ch3\u003eModel Identification Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModel: KJ3001X1-BH1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePart Number: 12P0558X152\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSeries: DeltaV SIS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFunction: Signal Isolation and Conditioning\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eKJ3001X1-BH1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEmerson\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.22 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.1 cm x 12.5 cm x 10.4 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard industrial range\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBackplane dependent\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCompatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDeltaV SIS \/ DCS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDeltaV Process Control \u0026amp; Instrumentation Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe card incorporates channel-to-channel isolation to prevent ground loops and mitigate electromagnetic interference between field sensors and the logic solver. It supports the 4-20 mA HART loop protocol, allowing for transparent pass-through of diagnostic data from field instrumentation. The internal circuitry is optimized for high-density integration, ensuring that signal pathways maintain linearity and accuracy during A\/D conversion processes. Cold junction compensation (CJC) is managed through the host carrier backplane to ensure precision in thermal measurement applications connected via this isolation layer.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) KJ3001X1-BH1 Isolated Card\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStandard DeltaV carrier mounting hardware\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTechnical documentation for integration into DeltaV SIS systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCarrier Mounting: Secure the module onto the designated DeltaV carrier backplane slot. Ensure proper alignment of the keying pins before applying pressure to seat the module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWiring Termination: Connect field signals to the terminal blocks on the carrier. Utilize shielded twisted-pair cabling and bond shields at the designated grounding bar to minimize common-mode noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHot-Swapping: The module supports hot-swapping; verify the carrier is powered and the system is configured to handle module removal before extracting the card from the backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerification: After installation, perform a loop check using the DeltaV engineering workstation to confirm signal values align with calibrated field inputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is this module hot-swappable in a running system?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the KJ3001X1-BH1 is designed for hot-swap operations within a powered DeltaV carrier, provided the safety system logic is configured to recognize the module status change.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How does the isolation protect the DCS?\u003c\/p\u003e\n\u003cp\u003eA: The module creates a galvanic barrier that prevents electrical faults or high-voltage transients on the field wiring from propagating to the sensitive logic solver circuitry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does this module require internal configuration?\u003c\/p\u003e\n\u003cp\u003eA: No, module configuration is performed automatically by the DeltaV controller upon insertion; parameters are defined within the system software environment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can I use this card with non-HART sensors?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the isolation and signal conditioning are passive to the data protocol, allowing for operation with standard 4-20 mA sensors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the purpose of the HS Code 8537101190?\u003c\/p\u003e\n\u003cp\u003eA: This code is used for customs classification of electrical control panels and modules to facilitate international shipping and regulatory compliance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the module compatible with standard DeltaV I\/O carriers?\u003c\/p\u003e\n\u003cp\u003eA: It is specifically engineered for integration into DeltaV SIS and DCS carrier backplanes; check hardware revision compatibility in the Emerson system manual.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How are failures reported?\u003c\/p\u003e\n\u003cp\u003eA: The module reports health status to the DeltaV controller, which triggers diagnostic alarms in the HMI if an internal failure or signal loss is detected.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the card consume significant backplane power?\u003c\/p\u003e\n\u003cp\u003eA: Power consumption is minimized for high-density deployments; refer to the Emerson power planning tools for specific wattage calculations based on total system I\/O.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":45519127478445,"sku":"KJ3001X1-BH1","price":1599.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/emerson-kj3001x1-bh1-12p0558x152-isolated-card-5m0ayzd5wdw.jpg?v=1766987509","url":"https:\/\/www.maxwellplc.com\/products\/kj3001x1-bh1-12p0558x152-emerson-isolated-card-deltav-sis-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}