{"product_id":"kfu8-crg2-1-d-pepperl-fuchs-transmitter-power-supply-k-system","title":"KFU8-CRG2-1.D Pepperl+Fuchs Transmitter Power Supply K-System","description":"\u003cp dir=\"auto\" data-start=\"257\" data-end=\"668\" class=\"PDq2pG_selectionAnchorContainer\"\u003eConfigured for analog signal conditioning and galvanic isolation, the \u003cstrong data-start=\"327\" data-end=\"358\"\u003ePepperl+Fuchs KFU8-CRG2-1.D\u003c\/strong\u003e (\u003cstrong data-start=\"360\" data-end=\"377\"\u003eKFU8-CRG2-1.D\u003c\/strong\u003e Transmitter Power Supply) supplies 2-wire and 3-wire transmitters or active current sources and provides a 0\/4-20 mA control-side output with two relay outputs. The unit also provides line fault detection, programmable alarms, and signal linearization. \u003cspan class=\"contents\" data-content-reference-start=\"631\" data-content-reference-end=\"664\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"pzqvvd\" dir=\"auto\" data-start=\"670\" data-end=\"693\"\u003eModel Configuration\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"695\" data-end=\"1096\"\u003eThe KFU8-CRG2-1.D is a single-channel signal conditioner. The available configuration provides one analog input, two relay outputs associated with Output I and Output II, and one active analog current output. The manufacturer specifies the device for non-intrinsically-safe applications; it should not be confused with the similarly named KFU8-CRG2-Ex1.D variant. \u003cspan class=\"contents\" data-content-reference-start=\"1055\" data-content-reference-end=\"1088\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"125glhy\" dir=\"auto\" data-start=\"1098\" data-end=\"1125\"\u003eHardware Specifications\u003c\/h3\u003e\n\u003cdiv dir=\"auto\" class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1127\" data-end=\"2604\" dir=\"auto\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1127\" data-end=\"1156\"\u003e\n\u003ctr data-start=\"1127\" data-end=\"1156\"\u003e\n\u003cth data-start=\"1127\" data-end=\"1139\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"1139\" data-end=\"1156\" data-col-size=\"md\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1167\" data-end=\"2604\"\u003e\n\u003ctr data-start=\"1167\" data-end=\"1192\"\u003e\n\u003ctd data-start=\"1167\" data-end=\"1175\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"1175\" data-end=\"1192\" data-col-size=\"md\"\u003eKFU8-CRG2-1.D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1193\" data-end=\"1218\"\u003e\n\u003ctd data-start=\"1193\" data-end=\"1201\" data-col-size=\"sm\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-start=\"1201\" data-end=\"1218\" data-col-size=\"md\"\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1219\" data-end=\"1262\"\u003e\n\u003ctd data-start=\"1219\" data-end=\"1234\" data-col-size=\"sm\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1234\" data-end=\"1262\"\u003eTransmitter Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1263\" data-end=\"1284\"\u003e\n\u003ctd data-start=\"1263\" data-end=\"1272\" data-col-size=\"sm\"\u003eSeries\u003c\/td\u003e\n\u003ctd data-start=\"1272\" data-end=\"1284\" data-col-size=\"md\"\u003eK-System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1285\" data-end=\"1305\"\u003e\n\u003ctd data-start=\"1285\" data-end=\"1294\" data-col-size=\"sm\"\u003eOrigin\u003c\/td\u003e\n\u003ctd data-start=\"1294\" data-end=\"1305\" data-col-size=\"md\"\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1306\" data-end=\"1324\"\u003e\n\u003ctd data-start=\"1306\" data-end=\"1315\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"1315\" data-end=\"1324\" data-col-size=\"md\"\u003e300 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1325\" data-end=\"1438\"\u003e\n\u003ctd data-start=\"1325\" data-end=\"1347\" data-col-size=\"sm\"\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd data-start=\"1347\" data-end=\"1438\" data-col-size=\"md\"\u003e40 x 119 x 115 mm housing dimensions; external shipping carton dimensions not specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1439\" data-end=\"1475\"\u003e\n\u003ctd data-start=\"1439\" data-end=\"1456\" data-col-size=\"sm\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd data-start=\"1456\" data-end=\"1475\" data-col-size=\"md\"\u003e-20 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1476\" data-end=\"1512\"\u003e\n\u003ctd data-start=\"1476\" data-end=\"1496\" data-col-size=\"sm\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-start=\"1496\" data-end=\"1512\" data-col-size=\"md\"\u003e2.2 W \/ 4 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1513\" data-end=\"1547\"\u003e\n\u003ctd data-start=\"1513\" data-end=\"1533\" data-col-size=\"sm\"\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd data-start=\"1533\" data-end=\"1547\" data-col-size=\"md\"\u003e2 W \/ 3 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1548\" data-end=\"1600\"\u003e\n\u003ctd data-start=\"1548\" data-end=\"1565\" data-col-size=\"sm\"\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd data-start=\"1565\" data-end=\"1600\" data-col-size=\"md\"\u003e20 to 90 V DC or 48 to 253 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1601\" data-end=\"1641\"\u003e\n\u003ctd data-start=\"1601\" data-end=\"1621\" data-col-size=\"sm\"\u003eSupply Connection\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1621\" data-end=\"1641\"\u003eTerminals 23, 24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1642\" data-end=\"1665\"\u003e\n\u003ctd data-start=\"1642\" data-end=\"1655\" data-col-size=\"sm\"\u003eInput Type\u003c\/td\u003e\n\u003ctd data-start=\"1655\" data-end=\"1665\" data-col-size=\"md\"\u003eAnalog\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1666\" data-end=\"1697\"\u003e\n\u003ctd data-start=\"1666\" data-end=\"1681\" data-col-size=\"sm\"\u003eInput Signal\u003c\/td\u003e\n\u003ctd data-start=\"1681\" data-end=\"1697\" data-col-size=\"md\"\u003e0\/4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1698\" data-end=\"1738\"\u003e\n\u003ctd data-start=\"1698\" data-end=\"1717\" data-col-size=\"sm\"\u003eInput Connection\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1717\" data-end=\"1738\"\u003eTerminals 1, 2, 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1739\" data-end=\"1783\"\u003e\n\u003ctd data-start=\"1739\" data-end=\"1765\" data-col-size=\"sm\"\u003eAvailable Input Voltage\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1765\" data-end=\"1783\"\u003e\u0026gt;15 V at 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1784\" data-end=\"1815\"\u003e\n\u003ctd data-start=\"1784\" data-end=\"1807\" data-col-size=\"sm\"\u003eOpen Circuit Voltage\u003c\/td\u003e\n\u003ctd data-start=\"1807\" data-end=\"1815\" data-col-size=\"md\"\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1816\" data-end=\"1849\"\u003e\n\u003ctd data-start=\"1816\" data-end=\"1840\" data-col-size=\"sm\"\u003eShort-Circuit Current\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1840\" data-end=\"1849\"\u003e33 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1850\" data-end=\"1897\"\u003e\n\u003ctd data-start=\"1850\" data-end=\"1869\" data-col-size=\"sm\"\u003eInput Resistance\u003c\/td\u003e\n\u003ctd data-start=\"1869\" data-end=\"1897\" data-col-size=\"md\"\u003e45 ohm at terminals 2, 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1898\" data-end=\"1971\"\u003e\n\u003ctd data-start=\"1898\" data-end=\"1921\" data-col-size=\"sm\"\u003eLine Fault Detection\u003c\/td\u003e\n\u003ctd data-start=\"1921\" data-end=\"1971\" data-col-size=\"md\"\u003eBreakage: I \u0026lt; 0.2 mA; short circuit: I \u0026gt; 22 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1972\" data-end=\"2016\"\u003e\n\u003ctd data-start=\"1972\" data-end=\"1988\" data-col-size=\"sm\"\u003eOutput Signal\u003c\/td\u003e\n\u003ctd data-start=\"1988\" data-end=\"2016\" data-col-size=\"md\"\u003e0 to 20 mA or 4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2017\" data-end=\"2064\"\u003e\n\u003ctd data-start=\"2017\" data-end=\"2044\" data-col-size=\"sm\"\u003eAnalog Output Connection\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2044\" data-end=\"2064\"\u003eTerminals 8+, 7-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2065\" data-end=\"2086\"\u003e\n\u003ctd data-start=\"2065\" data-end=\"2081\" data-col-size=\"sm\"\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd data-start=\"2081\" data-end=\"2086\" data-col-size=\"md\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2087\" data-end=\"2181\"\u003e\n\u003ctd data-start=\"2087\" data-end=\"2114\" data-col-size=\"sm\"\u003eRelay Output Connections\u003c\/td\u003e\n\u003ctd data-start=\"2114\" data-end=\"2181\" data-col-size=\"md\"\u003eOutput I: terminals 10, 11, 12; Output II: terminals 16, 17, 18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2182\" data-end=\"2255\"\u003e\n\u003ctd data-start=\"2182\" data-end=\"2205\" data-col-size=\"sm\"\u003eRelay Contact Rating\u003c\/td\u003e\n\u003ctd data-start=\"2205\" data-end=\"2255\" data-col-size=\"md\"\u003e250 V AC \/ 2 A \/ cos phi \u0026gt;= 0.7; 40 V DC \/ 2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2256\" data-end=\"2309\"\u003e\n\u003ctd data-start=\"2256\" data-end=\"2280\" data-col-size=\"sm\"\u003eRelay Mechanical Life\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2280\" data-end=\"2309\"\u003e5 x 10^7 switching cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2310\" data-end=\"2375\"\u003e\n\u003ctd data-start=\"2310\" data-end=\"2334\" data-col-size=\"sm\"\u003eProgramming Interface\u003c\/td\u003e\n\u003ctd data-start=\"2334\" data-end=\"2375\" data-col-size=\"md\"\u003eProgramming socket \/ RS-232 interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2376\" data-end=\"2400\"\u003e\n\u003ctd data-start=\"2376\" data-end=\"2386\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"2386\" data-end=\"2400\" data-col-size=\"md\"\u003eLC display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2401\" data-end=\"2461\"\u003e\n\u003ctd data-start=\"2401\" data-end=\"2412\" data-col-size=\"sm\"\u003eMounting\u003c\/td\u003e\n\u003ctd data-start=\"2412\" data-end=\"2461\" data-col-size=\"md\"\u003e35 mm DIN mounting rail according to EN 60715\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2462\" data-end=\"2494\"\u003e\n\u003ctd data-start=\"2462\" data-end=\"2475\" data-col-size=\"sm\"\u003eConnection\u003c\/td\u003e\n\u003ctd data-start=\"2475\" data-end=\"2494\" data-col-size=\"md\"\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2495\" data-end=\"2526\"\u003e\n\u003ctd data-start=\"2495\" data-end=\"2518\" data-col-size=\"sm\"\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2518\" data-end=\"2526\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2527\" data-end=\"2604\"\u003e\n\u003ctd data-start=\"2527\" data-end=\"2552\" data-col-size=\"sm\"\u003eSafety Integrity Level\u003c\/td\u003e\n\u003ctd data-start=\"2552\" data-end=\"2604\" data-col-size=\"md\"\u003eSIL 2 according to IEC\/EN 61508 and IEC\/EN 61511\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp dir=\"auto\" data-start=\"2606\" data-end=\"2761\"\u003eThe electrical and mechanical values above are taken from the current Pepperl+Fuchs technical data for KFU8-CRG2-1.D. \u003cspan class=\"contents\" data-content-reference-start=\"2716\" data-content-reference-end=\"2749\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"iuba3g\" dir=\"auto\" data-start=\"2763\" data-end=\"2809\"\u003eDIN-Rail Signal Conditioning and Isolation\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2811\" data-end=\"3134\"\u003eThe KFU8-CRG2-1.D provides galvanic isolation between field circuits and control circuits. The field input accepts 2-wire and 3-wire transmitters as well as active current sources. The control-side interface provides an active 0\/4 to 20 mA current output and two relay contact outputs. \u003cspan class=\"contents\" data-content-reference-start=\"3085\" data-content-reference-end=\"3105\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3136\" data-end=\"3438\"\u003eThe analog output can be scaled, while the LCD can display the measured value in different physical units. The device also provides programmable high and low alarms, adjustable energized\/de-energized delay, and a linearization function with a maximum of 20 points. \u003cspan class=\"contents\" data-content-reference-start=\"3372\" data-content-reference-end=\"3391\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3440\" data-end=\"3665\"\u003eFor installation, the unit uses a 35 mm DIN mounting rail and screw-terminal connections. The specified housing dimensions are 40 x 119 x 115 mm, with a mass of 300 g and IP20 protection. \u003cspan class=\"contents\" data-content-reference-start=\"3581\" data-content-reference-end=\"3601\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"9mzjr8\" dir=\"auto\" data-start=\"3667\" data-end=\"3691\"\u003eOrdering Information\u003c\/h3\u003e\n\u003cul data-start=\"3693\" data-end=\"4293\"\u003e\n\u003cli data-section-id=\"g1of8i\" data-start=\"3693\" data-end=\"3715\"\u003eModel: KFU8-CRG2-1.D\u003c\/li\u003e\n\u003cli data-section-id=\"1wa72wc\" data-start=\"3716\" data-end=\"3742\"\u003eProduct family: K-System\u003c\/li\u003e\n\u003cli data-section-id=\"ka29nb\" data-start=\"3743\" data-end=\"3782\"\u003eDevice type: Transmitter Power Supply\u003c\/li\u003e\n\u003cli data-section-id=\"dd1tdw\" data-start=\"3783\" data-end=\"3836\"\u003eChannel configuration: 1-channel signal conditioner\u003c\/li\u003e\n\u003cli data-section-id=\"xnattt\" data-start=\"3837\" data-end=\"3874\"\u003eField connection: Terminals 1, 2, 3\u003c\/li\u003e\n\u003cli data-section-id=\"1w8i2is\" data-start=\"3875\" data-end=\"3921\"\u003eControl-side analog output: Terminals 8+, 7-\u003c\/li\u003e\n\u003cli data-section-id=\"pbfq67\" data-start=\"3922\" data-end=\"3961\"\u003eRelay outputs: Output I and Output II\u003c\/li\u003e\n\u003cli data-section-id=\"j87djb\" data-start=\"3962\" data-end=\"3998\"\u003ePower connection: Terminals 23, 24\u003c\/li\u003e\n\u003cli data-section-id=\"1eljjpf\" data-start=\"3999\" data-end=\"4088\"\u003eProgramming: Front programming interface and compatible PACTware configuration software\u003c\/li\u003e\n\u003cli data-section-id=\"nk36hc\" data-start=\"4089\" data-end=\"4293\"\u003eOptional system components listed by the manufacturer include the K-ADP-USB programming adapter, PACTware 5.0, DTM interface technology, and K-DUCT-GY profile rail. \u003cspan class=\"contents\" data-content-reference-start=\"4192\" data-content-reference-end=\"4212\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"17bes7z\" dir=\"auto\" data-start=\"4295\" data-end=\"4328\"\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"4330\" data-end=\"4351\"\u003e\u003cstrong data-start=\"4330\" data-end=\"4351\"\u003eDIN-rail mounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"4353\" data-end=\"4664\"\u003e\n\u003cli data-section-id=\"1li1xex\" data-start=\"4353\" data-end=\"4423\"\u003eMount the device on a 35 mm DIN mounting rail according to EN 60715.\u003c\/li\u003e\n\u003cli data-section-id=\"byi0gx\" data-start=\"4424\" data-end=\"4504\"\u003eAllow access to the removable screw terminals and front programming interface.\u003c\/li\u003e\n\u003cli data-section-id=\"1tujky0\" data-start=\"4505\" data-end=\"4559\"\u003eObserve the -20 to 60 deg C ambient operating range.\u003c\/li\u003e\n\u003cli data-section-id=\"gw4kb8\" data-start=\"4560\" data-end=\"4664\"\u003eThe IP20 enclosure requires installation inside an appropriate protected control cabinet or enclosure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\" data-start=\"4666\" data-end=\"4683\"\u003e\u003cstrong data-start=\"4666\" data-end=\"4683\"\u003eSignal wiring\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"4685\" data-end=\"5031\"\u003e\n\u003cli data-section-id=\"1j5qn8d\" data-start=\"4685\" data-end=\"4791\"\u003eConnect the field transmitter according to the applicable terminal assignment for terminals 1, 2, and 3.\u003c\/li\u003e\n\u003cli data-section-id=\"1mwbny2\" data-start=\"4792\" data-end=\"4859\"\u003eVerify 2-wire or 3-wire transmitter wiring before applying power.\u003c\/li\u003e\n\u003cli data-section-id=\"q7863z\" data-start=\"4860\" data-end=\"4937\"\u003eCheck loop polarity and available transmitter voltage during commissioning.\u003c\/li\u003e\n\u003cli data-section-id=\"1k6tmpq\" data-start=\"4938\" data-end=\"5031\"\u003eKeep analog signal wiring separated from high-current switching conductors where practical.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\" data-start=\"5033\" data-end=\"5067\"\u003e\u003cstrong data-start=\"5033\" data-end=\"5067\"\u003eRelay and analog output wiring\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"5069\" data-end=\"5381\"\u003e\n\u003cli data-section-id=\"1nmow9n\" data-start=\"5069\" data-end=\"5131\"\u003eConnect Output I relay contacts to terminals 10, 11, and 12.\u003c\/li\u003e\n\u003cli data-section-id=\"aubk2g\" data-start=\"5132\" data-end=\"5195\"\u003eConnect Output II relay contacts to terminals 16, 17, and 18.\u003c\/li\u003e\n\u003cli data-section-id=\"14qu4c3\" data-start=\"5196\" data-end=\"5255\"\u003eConnect the analog current output to terminals 8+ and 7-.\u003c\/li\u003e\n\u003cli data-section-id=\"5q55o1\" data-start=\"5256\" data-end=\"5381\"\u003eDo not exceed the specified relay contact ratings of 250 V AC \/ 2 A or 40 V DC \/ 2 A. \u003cspan class=\"contents\" data-content-reference-start=\"5263\" data-content-reference-end=\"5282\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\" data-start=\"5383\" data-end=\"5400\"\u003e\u003cstrong data-start=\"5383\" data-end=\"5400\"\u003eConfiguration\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"5402\" data-end=\"5718\"\u003e\n\u003cli data-section-id=\"1205wqh\" data-start=\"5402\" data-end=\"5457\"\u003eUse the front keypad and LCD for local configuration.\u003c\/li\u003e\n\u003cli data-section-id=\"1i8la3b\" data-start=\"5458\" data-end=\"5547\"\u003ePACTware can be used with the appropriate interface technology and programming adapter.\u003c\/li\u003e\n\u003cli data-section-id=\"40fae2\" data-start=\"5548\" data-end=\"5718\"\u003eVerify alarm thresholds, delay settings, output scaling, and linearization parameters before placing the signal loop into service. \u003cspan class=\"contents\" data-content-reference-start=\"5582\" data-content-reference-end=\"5602\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"143lnue\" dir=\"auto\" data-start=\"5720\" data-end=\"5744\"\u003eDelivery Information\u003c\/h3\u003e\n\u003cul data-start=\"5746\" data-end=\"5935\"\u003e\n\u003cli data-section-id=\"xesp7b\" data-start=\"5746\" data-end=\"5797\"\u003eDelivery time: 3-5 days when payment is finished.\u003c\/li\u003e\n\u003cli data-section-id=\"1htht1b\" data-start=\"5798\" data-end=\"5829\"\u003eShipping: DHL, FedEx, or UPS.\u003c\/li\u003e\n\u003cli data-section-id=\"9egayz\" data-start=\"5830\" data-end=\"5935\"\u003ePackaging: anti-static industrial packaging with impact protection for industrial electronic equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"ul2pwc\" dir=\"auto\" data-start=\"5937\" data-end=\"5967\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"5969\" data-end=\"6167\"\u003e\u003cstrong data-start=\"5969\" data-end=\"6031\"\u003eQ: What type of transmitters can the KFU8-CRG2-1.D supply?\u003c\/strong\u003e\u003cbr data-start=\"6031\" data-end=\"6034\"\u003eA: It supports 2-wire and 3-wire transmitters and can also be used with active current sources. \u003cspan class=\"contents\" data-content-reference-start=\"6014\" data-content-reference-end=\"6033\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"6169\" data-end=\"6345\"\u003e\u003cstrong data-start=\"6169\" data-end=\"6217\"\u003eQ: What analog output signals are available?\u003c\/strong\u003e\u003cbr data-start=\"6217\" data-end=\"6220\"\u003eA: The active analog output can be configured for 0 to 20 mA or 4 to 20 mA operation. \u003cspan class=\"contents\" data-content-reference-start=\"6172\" data-content-reference-end=\"6191\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"6347\" data-end=\"6564\"\u003e\u003cstrong data-start=\"6347\" data-end=\"6397\"\u003eQ: Does the unit provide line fault detection?\u003c\/strong\u003e\u003cbr data-start=\"6397\" data-end=\"6400\"\u003eA: Yes. The specified detection thresholds are below 0.2 mA for input line breakage and above 22 mA for input short circuit. \u003cspan class=\"contents\" data-content-reference-start=\"6371\" data-content-reference-end=\"6390\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"6566\" data-end=\"6745\"\u003e\u003cstrong data-start=\"6566\" data-end=\"6614\"\u003eQ: What is the maximum relay contact rating?\u003c\/strong\u003e\u003cbr data-start=\"6614\" data-end=\"6617\"\u003eA: The relay contacts are rated at 250 V AC \/ 2 A with cos phi \u0026gt;= 0.7, or 40 V DC \/ 2 A. \u003cspan class=\"contents\" data-content-reference-start=\"6532\" data-content-reference-end=\"6551\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"6747\" data-end=\"6914\"\u003e\u003cstrong data-start=\"6747\" data-end=\"6790\"\u003eQ: Can the analog signal be linearized?\u003c\/strong\u003e\u003cbr data-start=\"6790\" data-end=\"6793\"\u003eA: Yes. The device provides a linearization function with a maximum of 20 points.\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":47508764328109,"sku":"KFU8-CRG2-1D","price":483.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/kfu8-ufc-1.d_1.jpg?v=1789090632","url":"https:\/\/www.maxwellplc.com\/products\/kfu8-crg2-1-d-pepperl-fuchs-transmitter-power-supply-k-system","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}