{"product_id":"is230snrlh2a-general-electric-mark-vie-discreet-output-relay-module","title":"IS230SNRLH2A General Electric Mark VIe Discreet Output Relay Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe GE IS230SNRLH2A is a discrete output relay module designed to switch external loads from a GE control system using relay-isolated outputs. It is commonly deployed where field devices such as interposing relays, solenoids, alarms, and contactor coils must be driven with electrical isolation and clear ON\/OFF state control. The module is built for industrial control cabinets and is typically mounted in DIN-rail assemblies as part of GE excitation and turbine control hardware families.\u003c\/p\u003e\n\u003cp\u003eThis relay output module supports maintainable wiring practices and improves fault finding by separating control electronics from field power circuits. It is used as a spare or replacement module in installed systems where reliable discrete actuation is required.\u003c\/p\u003e\n\u003ch3\u003eHardware Parameters\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Part number\u003c\/td\u003e\n\u003ctd\u003eIS230SNRLH2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule category\u003c\/td\u003e\n\u003ctd\u003eDiscrete Output Relay Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct family reference\u003c\/td\u003e\n\u003ctd\u003eEX2100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput type\u003c\/td\u003e\n\u003ctd\u003eRelay-switched discrete outputs (dry-contact style switching)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eRelay isolation between control side and field circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN-rail module format (panel integration dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical use\u003c\/td\u003e\n\u003ctd\u003eDriving coils, annunciation circuits, interposing relays, and permissive\/trip logic interfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003eBrand New\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLead time\u003c\/td\u003e\n\u003ctd\u003eIn Stock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.02 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (listing)\u003c\/td\u003e\n\u003ctd\u003e20.5 × 17 × 7.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of origin (listing)\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHS code (listing)\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem category\u003c\/td\u003e\n\u003ctd\u003eDCS \/ industrial control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRecommended practices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eUse appropriately rated fusing and suppression for inductive loads (coils\/solenoids)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFollow cabinet grounding and segregation rules to reduce noise coupling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify relay contact ratings against the actual load and inrush current (application-specific)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEX2100 excitation control cabinets requiring relay-isolated discrete actuation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower generation auxiliary control including alarms, permissives, and interlocks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTurbine and generator balance-of-plant automation where discrete outputs must interface to higher-energy field circuits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRetrofit and spare replacement for DIN-rail output modules in legacy GE control installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45519068037293,"sku":"IS230SNRLH2A","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/general-electric-is230snrlh2a-discreet-output-relay-module-tp3cjthgfda.jpg?v=1766986116","url":"https:\/\/www.maxwellplc.com\/products\/is230snrlh2a-general-electric-mark-vie-discreet-output-relay-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}