{"product_id":"is230jpdmg1b-general-electric-mark-vie-remote-i-o-module","title":"IS230JPDMG1B General Electric Mark VIe Remote I\/O Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE IS230JPDMG1B\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eJPDM power distribution board\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eused in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMark VIe control cabinet power distribution (PDM) assemblies\u003c\/strong\u003e. Its primary role is to accept\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e28 VDC input power\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom external conversion supplies and distribute protected DC power to controllers and cabinet loads. In addition to power routing, the board provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003estatus\/feedback signaling\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto an associated I\/O pack so the control system can monitor bus health and fuse conditions.\u003c\/p\u003e\n\u003cp\u003eThis module supports multiple DC buses and can be applied in configurations requiring either independent buses or redundancy via jumper-selected arrangements, depending on the cabinet design and wiring scheme.\u003c\/p\u003e\n\u003ch3\u003eHardware Parameters\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS230JPDMG1B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003ePower Distribution Feedback Module (JPDM Board)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl platform\u003c\/td\u003e\n\u003ctd\u003eMark VIe (PDM cabinet architecture)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal input\u003c\/td\u003e\n\u003ctd\u003e28 VDC (from external AC\/DC or DC\/DC supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower buses\u003c\/td\u003e\n\u003ctd\u003e3 buses (R, S, T)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput protection\u003c\/td\u003e\n\u003ctd\u003eFused outputs for distributed loads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring interface\u003c\/td\u003e\n\u003ctd\u003eFeedback to PPDA I\/O pack via DC-62 connection (JA1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O \/ diagnostic links\u003c\/td\u003e\n\u003ctd\u003eRibbon cable connectors (P1, P2) for feedback\/diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput connectors (typical)\u003c\/td\u003e\n\u003ctd\u003eMate-N-Lok style outputs for load distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse rating (typical per output)\u003c\/td\u003e\n\u003ctd\u003e10 A (per protected output feed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003eBrand New\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailability\u003c\/td\u003e\n\u003ctd\u003eIn Stock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.02 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e20.5 × 17 × 7.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of origin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHS Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscontinued status\u003c\/td\u003e\n\u003ctd\u003eActive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMOQ\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKey Technical Characteristics\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e28 VDC cabinet power distribution\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor Mark VIe PDM architectures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThree-bus design\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupporting segmented power routing (R\/S\/T) and flexible cabinet builds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eJumper-selectable bus tying\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto implement redundant supply arrangements where required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFused load feeds\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto reduce fault propagation and support maintainable cabinet protection practices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated feedback signaling\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto the monitoring I\/O pack for bus state and power condition visibility\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExpandable wiring approach\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenabling interconnection between adjacent distribution boards (cabinet dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTurbine and generator control cabinets\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eusing Mark VIe power distribution modules for DC load feeding\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDistributed control system power panels\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhere continuous monitoring of DC buses improves availability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant DC supply designs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequiring bus paralleling or dual-source configurations (as engineered)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaintenance replacement\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor PDM cabinets where like-for-like JPDM board interchange is required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45519069577389,"sku":"IS230JPDMG1B","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/general-electric-is230jpdmg1b-remote-input-output-rio-module-x5i1aoibkw0.jpg?v=1766986165","url":"https:\/\/www.maxwellplc.com\/products\/is230jpdmg1b-general-electric-mark-vie-remote-i-o-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}