{"product_id":"is200vturh1b-general-electric-is200vturh1baa-mark-vi-turbine-card","title":"IS200VTURH1B General Electric IS200VTURH1BAA Mark VI Turbine Card","description":"\u003ch3 data-start=\"103\" data-end=\"123\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp data-start=\"124\" data-end=\"614\"\u003eThe \u003cstrong data-start=\"128\" data-end=\"163\"\u003eGeneral Electric IS200VTURH1BAA\u003c\/strong\u003e is a \u003cstrong data-start=\"169\" data-end=\"224\"\u003eprimary turbine protection and trip interface board\u003c\/strong\u003e used in GE Mark-series turbine control architectures. It supports critical protective functions by processing speed-related inputs and coordinating trip logic outputs used to actuate emergency shutdown devices. The board is typically applied in control cabinets for \u003cstrong data-start=\"491\" data-end=\"517\"\u003egas and steam turbines\u003c\/strong\u003e, where reliable primary protection is required for safe operation and coordinated plant control.\u003c\/p\u003e\n\u003cp data-start=\"616\" data-end=\"807\"\u003eThis card is commonly installed in a VME-style rack environment and is selected by exact part number to maintain form, fit, and function compatibility in existing Mark VI\/Mark-family systems.\u003c\/p\u003e\n\u003ch3 data-start=\"809\" data-end=\"832\"\u003eHardware Parameters\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"833\" data-end=\"1801\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"833\" data-end=\"857\"\u003e\n\u003ctr data-start=\"833\" data-end=\"857\"\u003e\n\u003cth data-start=\"833\" data-end=\"840\" data-col-size=\"md\"\u003eItem\u003c\/th\u003e\n\u003cth data-start=\"840\" data-end=\"857\" data-col-size=\"md\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"868\" data-end=\"1801\"\u003e\n\u003ctr data-start=\"868\" data-end=\"894\"\u003e\n\u003ctd data-start=\"868\" data-end=\"876\" data-col-size=\"md\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"876\" data-end=\"894\" data-col-size=\"md\"\u003eIS200VTURH1BAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"895\" data-end=\"953\"\u003e\n\u003ctd data-start=\"895\" data-end=\"910\" data-col-size=\"md\"\u003eProduct type\u003c\/td\u003e\n\u003ctd data-start=\"910\" data-end=\"953\" data-col-size=\"md\"\u003ePrimary Turbine Protection \/ Trip Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"954\" data-end=\"1031\"\u003e\n\u003ctd data-start=\"954\" data-end=\"971\" data-col-size=\"md\"\u003eProduct series\u003c\/td\u003e\n\u003ctd data-start=\"971\" data-end=\"1031\" data-col-size=\"md\"\u003eMark VIe (commonly used in Mark VI family architectures)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1032\" data-end=\"1048\"\u003e\n\u003ctd data-start=\"1032\" data-end=\"1041\" data-col-size=\"md\"\u003eSystem\u003c\/td\u003e\n\u003ctd data-start=\"1041\" data-end=\"1048\" data-col-size=\"md\"\u003eDCS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1049\" data-end=\"1127\"\u003e\n\u003ctd data-start=\"1049\" data-end=\"1081\" data-col-size=\"md\"\u003eSpeed input support (typical)\u003c\/td\u003e\n\u003ctd data-start=\"1081\" data-end=\"1127\" data-col-size=\"md\"\u003ePassive pulse rate devices, 2 Hz to 20 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1128\" data-end=\"1219\"\u003e\n\u003ctd data-start=\"1128\" data-end=\"1162\" data-col-size=\"md\"\u003eLow-speed sensitivity (typical)\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1162\" data-end=\"1219\"\u003eDetects very low RPM with millivolt-level pulse input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1220\" data-end=\"1331\"\u003e\n\u003ctd data-start=\"1220\" data-end=\"1265\" data-col-size=\"md\"\u003eFlame monitoring (typical gas turbine use)\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1265\" data-end=\"1331\"\u003eInterfaces for flame detector channels (application dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1332\" data-end=\"1446\"\u003e\n\u003ctd data-start=\"1332\" data-end=\"1364\" data-col-size=\"md\"\u003eTrip output control (typical)\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1364\" data-end=\"1446\"\u003eControls overspeed\/trip relay logic and shutdown actuation via terminal boards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1447\" data-end=\"1526\"\u003e\n\u003ctd data-start=\"1447\" data-end=\"1468\" data-col-size=\"md\"\u003eRedundancy support\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1468\" data-end=\"1526\"\u003eSimplex and TMR system implementations (as configured)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1527\" data-end=\"1590\"\u003e\n\u003ctd data-start=\"1527\" data-end=\"1552\" data-col-size=\"md\"\u003eFront-panel indicators\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1552\" data-end=\"1590\"\u003eRUN \/ FAIL \/ STATUS LEDs (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1591\" data-end=\"1616\"\u003e\n\u003ctd data-start=\"1591\" data-end=\"1603\" data-col-size=\"md\"\u003eCondition\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1603\" data-end=\"1616\"\u003eBrand New\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1617\" data-end=\"1644\"\u003e\n\u003ctd data-start=\"1617\" data-end=\"1632\" data-col-size=\"md\"\u003eAvailability\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1632\" data-end=\"1644\"\u003eIn Stock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1645\" data-end=\"1665\"\u003e\n\u003ctd data-start=\"1645\" data-end=\"1654\" data-col-size=\"md\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1654\" data-end=\"1665\"\u003e0.30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1666\" data-end=\"1703\"\u003e\n\u003ctd data-start=\"1666\" data-end=\"1679\" data-col-size=\"md\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1679\" data-end=\"1703\"\u003e2.1 × 18.6 × 26.1 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1704\" data-end=\"1731\"\u003e\n\u003ctd data-start=\"1704\" data-end=\"1724\" data-col-size=\"md\"\u003eCountry of origin\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1724\" data-end=\"1731\"\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1732\" data-end=\"1756\"\u003e\n\u003ctd data-start=\"1732\" data-end=\"1742\" data-col-size=\"md\"\u003eHS Code\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1742\" data-end=\"1756\"\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1757\" data-end=\"1789\"\u003e\n\u003ctd data-start=\"1757\" data-end=\"1779\" data-col-size=\"md\"\u003eDiscontinued status\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1779\" data-end=\"1789\"\u003eActive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1790\" data-end=\"1801\"\u003e\n\u003ctd data-start=\"1790\" data-end=\"1796\" data-col-size=\"md\"\u003eMOQ\u003c\/td\u003e\n\u003ctd data-start=\"1796\" data-end=\"1801\" data-col-size=\"md\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-start=\"1803\" data-end=\"1836\"\u003eKey Technical Characteristics\u003c\/h3\u003e\n\u003cul data-start=\"1837\" data-end=\"2375\"\u003e\n\u003cli data-start=\"1837\" data-end=\"1949\"\u003e\n\u003cp data-start=\"1839\" data-end=\"1949\"\u003e\u003cstrong data-start=\"1839\" data-end=\"1868\"\u003ePrimary trip coordination\u003c\/strong\u003e for turbine shutdown functions, including overspeed-related protective actions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1950\" data-end=\"2045\"\u003e\n\u003cp data-start=\"1952\" data-end=\"2045\"\u003e\u003cstrong data-start=\"1952\" data-end=\"1985\"\u003ePulse speed signal processing\u003c\/strong\u003e for turbine speed measurement and protection logic inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2046\" data-end=\"2156\"\u003e\n\u003cp data-start=\"2048\" data-end=\"2156\"\u003e\u003cstrong data-start=\"2048\" data-end=\"2088\"\u003eDesigned for redundant architectures\u003c\/strong\u003e supporting TMR deployments where required by availability targets\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2157\" data-end=\"2257\"\u003e\n\u003cp data-start=\"2159\" data-end=\"2257\"\u003e\u003cstrong data-start=\"2159\" data-end=\"2190\"\u003eRack-installed board format\u003c\/strong\u003e with front access for status indication and service connectivity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2258\" data-end=\"2375\"\u003e\n\u003cp data-start=\"2260\" data-end=\"2375\"\u003e\u003cstrong data-start=\"2260\" data-end=\"2285\"\u003eIndustrial durability\u003c\/strong\u003e suitable for turbine control cabinets and continuous-duty power generation environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"2377\" data-end=\"2404\"\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul data-start=\"2405\" data-end=\"2828\"\u003e\n\u003cli data-start=\"2405\" data-end=\"2512\"\u003e\n\u003cp data-start=\"2407\" data-end=\"2512\"\u003e\u003cstrong data-start=\"2407\" data-end=\"2441\"\u003eGas turbine protection systems\u003c\/strong\u003e requiring primary trip logic coordination and speed input processing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2513\" data-end=\"2611\"\u003e\n\u003cp data-start=\"2515\" data-end=\"2611\"\u003e\u003cstrong data-start=\"2515\" data-end=\"2555\"\u003eSteam turbine protection and control\u003c\/strong\u003e where high-integrity shutdown pathways are maintained\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2612\" data-end=\"2729\"\u003e\n\u003cp data-start=\"2614\" data-end=\"2729\"\u003e\u003cstrong data-start=\"2614\" data-end=\"2654\"\u003ePower plant modernization and spares\u003c\/strong\u003e where exact board replacement is needed to preserve existing rack wiring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2730\" data-end=\"2828\"\u003e\n\u003cp data-start=\"2732\" data-end=\"2828\"\u003e\u003cstrong data-start=\"2732\" data-end=\"2763\"\u003eTMR turbine control systems\u003c\/strong\u003e used in critical generation assets demanding high availability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45519070494893,"sku":"IS200VTURH1BAA","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/general-electric-is200vturh1baa-mk6-gas-tmr-pk-turbine-card-xa44c4jsdwa.jpg?v=1766986194","url":"https:\/\/www.maxwellplc.com\/products\/is200vturh1b-general-electric-is200vturh1baa-mark-vi-turbine-card","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}