{"product_id":"is200tgenh1a-general-electric-mark-vie-primary-trip-termination-board","title":"IS200TGENH1A General Electric Mark VIe Primary Trip Termination Board","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe IS200TGENH1A is a primary trip termination board used in GE Mark VIe turbine control and protection cabinets. It provides a structured interface between field wiring and the trip\/protection electronics, supporting clean signal termination and reliable cabinet-level connectivity in applications where trip integrity and maintainable wiring practices are required.\u003c\/p\u003e\n\u003cp\u003eThis board is typically installed in a control panel to consolidate terminations, simplify commissioning, and reduce wiring errors during maintenance. Terminal blocks and multi-pin connectors are used to route signals between the field and associated control modules or I\/O interfaces, depending on the specific Mark VIe panel design.\u003c\/p\u003e\n\u003cp\u003eData correction note\u003cbr\u003eThe functional text provided appears to describe a different terminal board (IS200TRPGH1BDE). The description below is written specifically for IS200TGENH1A based on its stated role as a primary trip terminal\/termination board.\u003c\/p\u003e\n\u003ch3\u003eHardware Parameters\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eBoard function: Primary trip termination and field wiring interface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSeries: Mark VIe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWiring style: Barrier\/terminal-block field termination with multi-pin board connectors for cabinet interconnect\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintainability: Clearly grouped terminals and connectorized interfaces for troubleshooting and replacement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule type\u003c\/td\u003e\n\u003ctd\u003ePrimary Trip Termination Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel number\u003c\/td\u003e\n\u003ctd\u003eIS200TGENH1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprox. weight\u003c\/td\u003e\n\u003ctd\u003e~0.22 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (approx.)\u003c\/td\u003e\n\u003ctd\u003e2.1 x 18.6 x 26.3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eControl cabinet \/ panel mounting (application dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eTypical terminal-board construction elements (may vary by build\/revision)\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMultiple terminal blocks for organized field landing points\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBoard-level components for signal conditioning and noise suppression where required by the trip circuit design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMulti-pin connectors for harnessed connections to related control or protection hardware\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePrimary trip circuit termination in gas and steam turbine control systems using Mark VIe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePanel wiring consolidation for trip signals, interlocks, and protection I\/O routing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReplacement of damaged or aging termination boards to restore correct cabinet wiring integrity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePlanned outage maintenance where connectorized boards reduce downtime and commissioning effort\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSites using redundant or high-integrity protection designs that require consistent terminal identification and stable interconnects\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45519073345709,"sku":"IS200TGENH1A","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/general-electric-is200tgenh1a-termination-board-djkejofjflv.jpg?v=1766986267","url":"https:\/\/www.maxwellplc.com\/products\/is200tgenh1a-general-electric-mark-vie-primary-trip-termination-board","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}