{"product_id":"ipecb13-abb-bailey-infi-90-power-entry-circuit-breaker","title":"IPECB13 ABB Bailey Infi 90 Power Entry Circuit Breaker","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB IPECB13\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIPECB13\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePower Entry Circuit Breaker, operates as a dedicated hardware component for branch power isolation and overcurrent interruption within Bailey Infi 90 power distribution assemblies. The breaker unit manages DC and AC input protection through mechanically actuated thermal-magnetic interruption circuitry connected to industrial control cabinet power entry sections.\u003c\/p\u003e\n\u003ch3\u003eProduct Configuration\u003c\/h3\u003e\n\u003cp\u003eThe IPECB13 is supplied as a fixed power protection assembly for ABB Bailey Infi 90 systems. Available technical data does not define configurable suffix-dependent hardware options or alternate catalog matrix structures.\u003c\/p\u003e\n\u003ch3\u003eElectrical and Mechanical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIPECB13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePower Entry Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eBailey Infi 90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003e125 VDC \/ 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e10 A, 13 A, 16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e4.5 kA to 10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e1P or 2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5-95 % RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e22.5 x 12.5 x 16.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlace of Shipment\u003c\/td\u003e\n\u003ctd\u003eXiamen, China\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive protection device without continuous power draw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePower Distribution and Protection Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe IPECB13 breaker assembly provides branch-level interruption protection for industrial control power distribution sections within ABB Infi 90 infrastructure. Thermal and magnetic trip mechanisms respond to sustained overload and instantaneous fault current conditions.\u003c\/p\u003e\n\u003cp\u003eMechanical contact interruption timing is dependent on breaker loading conditions and applied fault current magnitude. During installation, conductor termination torque and bus connection alignment should be verified to minimize resistive heating at connection points.\u003c\/p\u003e\n\u003cp\u003eThe breaker structure supports integration into deterministic industrial control power systems where cabinet-level isolation and branch segmentation are required for distributed module protection.\u003c\/p\u003e\n\u003ch3\u003eTechnical Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the IPECB13 support both AC and DC applications?\u003cbr\u003eA: The available technical data specifies operation at 125 VDC and 240 VAC system voltage conditions.\u003c\/p\u003e\n\u003cp\u003eQ: What trip current ratings are available for the breaker?\u003cbr\u003eA: Documented current ratings include 10 A, 13 A, and 16 A configurations.\u003c\/p\u003e\n\u003cp\u003eQ: What is the purpose of the breaking capacity specification?\u003cbr\u003eA: The breaking capacity defines the maximum fault current the breaker can interrupt without structural damage to the interruption mechanism.\u003c\/p\u003e\n\u003cp\u003eQ: Can the breaker be installed in single-pole and dual-pole configurations?\u003cbr\u003eA: Yes. The documented hardware supports 1P and 2P pole arrangements depending on installation requirements.\u003c\/p\u003e\n\u003cp\u003eQ: What installation factor most affects long-term contact stability?\u003cbr\u003eA: Improper conductor torque, loose bus termination hardware, and thermal cycling may increase connection resistance and localized heating.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation and Wiring Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eVerify complete de-energization of incoming power conductors before installation or servicing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain proper cabinet grounding continuity prior to energizing protected circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTighten terminal connections according to approved industrial electrical practices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSeparate control wiring from high-current feeder conductors where possible.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInspect breaker terminals and bus interfaces for oxidation or mechanical damage before installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain enclosure airflow conditions within specified operating temperature limits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse anti-static handling precautions when working near adjacent control electronics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIncluded Shipment Contents\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIPECB13 Power Entry Circuit Breaker\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial anti-static protective packaging\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStandard transport protection materials\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOptional associated hardware may include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePower distribution chassis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBus connection accessories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMounting hardware kits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackaging and Transport Information\u003c\/h3\u003e\n\u003cp\u003eDelivery time: 2-7 days when payment finish. Shipment available through DHL, FedEx, and UPS international industrial transport services.\u003c\/p\u003e\n\u003cp\u003eThe breaker assembly is packed using reinforced anti-static industrial packaging with internal cushioning to reduce mechanical stress during export handling and warehouse movement.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021115019437,"sku":"IPECB13","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/IPECB13_1.jpg?v=1779955779","url":"https:\/\/www.maxwellplc.com\/products\/ipecb13-abb-bailey-infi-90-power-entry-circuit-breaker","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}