{"product_id":"inipt01-abb-local-communication-modules-infi-90","title":"INIPT01 ABB Local Communication Modules Infi 90","description":"\u003cp\u003eThe \u003cstrong\u003eABB INIPT01\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eINIPT01\u003c\/strong\u003e Local Transfer Module, operates as a dedicated hardware component for high-speed data routing and plant loop interfacing within Infi 90 networks.\u003c\/p\u003e\n\u003ch3\u003eTechnical Parameters\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eINIPT01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSWEDEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e7.6 cm x 33.0 cm x 20.3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e8-15 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Protocol\u003c\/td\u003e\n\u003ctd\u003eMasterBus 300 \/ Infi-Net\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e500 V optical isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Routing and Backplane Velocity\u003c\/h3\u003e\n\u003cp\u003eThe INIPT01 acts as the communication link between the Infi-Net system and the local Plant Loop, utilizing the MasterBus 300 protocol layer. The internal architecture uses 500 V optical isolation to prevent electrical fault transmission between networks. Data throughput depends on stable backplane bus communication velocity parameters, allowing deterministic packet transfers without data dropping. The module supports maximum I\/O density scaling demands while maintaining stable execution routines across older and newer revisions due to broad firmware flash compatibility embedded in the interface controller.\u003c\/p\u003e\n\u003ch3\u003eHardware Interface FAQ\u003c\/h3\u003e\n\u003cp\u003eQ: What is the purpose of the 500 V optical isolation on the INIPT01?\u003c\/p\u003e\n\u003cp\u003eA: The 500 V optical isolation electrically separates the Infi-Net side from the Plant Loop side, suppressing ground loops and protecting internal processors from line-side surges.\u003c\/p\u003e\n\u003cp\u003eQ: Can this module be plugged into a live slot under full 24 VDC power?\u003c\/p\u003e\n\u003cp\u003eA: No, hot-swapping the INIPT01 can interrupt the MasterBus 300 token rotation and induce transient bus noise. The rack slot must be de-energized prior to hardware modification.\u003c\/p\u003e\n\u003cp\u003eQ: What are the effects of running this module at its +60 deg C operational limit?\u003c\/p\u003e\n\u003cp\u003eA: The module operates within spec up to +60 deg C, but dense packing with high I\/O density scaling cards requires monitored air displacement to prevent thermal drift in the communication chips.\u003c\/p\u003e\n\u003ch3\u003eField Assembly Regulations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Alignment:\u003c\/strong\u003e Insert the card vertically into the chassis guide rails to ensure the rear pins lock straight into the backplane bus socket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Shield Terminations:\u003c\/strong\u003e Fix external network communication shields to the system cabinet earth ground bar; do not daisy-chain the shields through adjacent cards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Wire Sizing:\u003c\/strong\u003e Connect the 24 VDC input using wire gauges that match the 15 W power consumption limits to keep DC line drops within acceptable tolerances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeparation Distance:\u003c\/strong\u003e Maintain a separate routing channel for network cables away from high-power inductive circuits to protect the data loop from interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eStandard Box Items\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x ABB INIPT01 Local Transfer Module\u003c\/li\u003e\n\u003cli\u003e1 x Hardware Address Jumper Pack\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLogistics and Packing Guidelines\u003c\/h3\u003e\n\u003cp\u003eDelivery time: 3-5 days when payment finish via global networks including DHL, FEDEX, and UPS. Modules are packed in heavy-duty anti-static industrial packaging sleeves with desiccant protection layers to prevent physical or electrical degradation during transport.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021110562989,"sku":"INIPT01","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/INIPT01.jpg?v=1779952963","url":"https:\/\/www.maxwellplc.com\/products\/inipt01-abb-local-communication-modules-infi-90","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}