{"product_id":"iniit12-abb-infi-net-to-infi-net-transfer-module-infi-90","title":"INIIT12 ABB Infi-Net to Infi-Net Transfer Module Infi 90","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB INIIT12\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eINIIT12\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInfi-Net to Infi-Net Transfer Module utilized to execute high-speed data unidirectional or bidirectional bridging across Infi 90 platforms. It establishes the physical and protocol interface required to route data packets between independent INFI-NET communication rings via integrated serial ports.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eINIIT12\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSWEDEN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.3 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e17.8 x 5.1 x 33.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to +60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to +70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHumidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5-95 % RH non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+5 VDC @ 2 A (10 W)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOnboard Memory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e256 kbytes ROM; 512 kbytes RAM; 256 kbytes NVRAM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication Ports\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 x RS-232-C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication Rates\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUser-selectable up to 19.2 kbaud\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSubcategory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePLC Communication Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTariff Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8537101190\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and System Firmware Integration\u003c\/h3\u003e\n\u003cp\u003eThe INIIT12 operates in strict compliance with the deterministic backplane bus communication velocity baselines defined for the Infi 90 module mounting unit. Data processing between separated processing rings is managed via local memory blocks, utilizing the 256 kbytes NVRAM segment to retain cross-ring node addresses and configuration mapping parameters during power disruptions. Firmware flash compatibility must be validated across all participating system network components to ensure that data packet routing across the dual RS-232-C channels avoids synchronization lag and transmission time-outs.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the specific power supply requirements for the INIIT12 module?\u003c\/p\u003e\n\u003cp\u003eA: The module demands a steady current load of 2 A at +5 VDC from the shared chassis backplane. Power distribution calculations must budget exactly 10 W for this slot to maintain overall voltage regulation.\u003c\/p\u003e\n\u003cp\u003eQ: How is the configuration mapping retained when the rack loses power?\u003c\/p\u003e\n\u003cp\u003eA: Node configurations and ring mapping parameters are stored within the 256 kbytes of onboard non-volatile RAM (NVRAM), bypassing the need for continuous backplane battery backup power.\u003c\/p\u003e\n\u003cp\u003eQ: Can this module card be extracted or replaced while the backplane bus is fully energized?\u003c\/p\u003e\n\u003cp\u003eA: No. The INIIT12 does not possess hot-swap capability. Removing or inserting the card while live can induce electrical transients that disrupt active data packets on the backplane or corrupt the onboard memory contents.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIsolate all incoming power sources connected to the module rack assembly before inserting or extracting the hardware card.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAlign the upper and lower circuit board edges carefully within the module guide tracks to guarantee full insertion into the backplane connector.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute all asynchronous RS-232-C serial cables in separate conduits isolated from high-current AC power cables or inductive motor control loads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eClamp the braided shields of all external serial communication cables directly to the central copper earth ground bus bar inside the enclosure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x INIIT12 Infi-Net to Infi-Net Transfer Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Factory Component Configuration Slip\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAnti-static protective shielding film packaging\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDelivery Information\u003c\/h3\u003e\n\u003cp\u003eAll components are packed inside specialized anti-static industrial packaging to negate ESD vulnerabilities during handling. Shipments are dispatched globally with typical tracking delivery cycles completed within 2-7 days when payment finish using premium DHL\/FEDEX\/UPS express air couriers.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021113708717,"sku":"INIIT12","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/INIIT02-3_5016a9a8-f8ae-4c93-b7f2-d76841c285b5.jpg?v=1779952840","url":"https:\/\/www.maxwellplc.com\/products\/iniit12-abb-infi-net-to-infi-net-transfer-module-infi-90","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}