{"product_id":"iniit01-abb-infinet-to-infinet-transfer-module-bailey-infi-90","title":"INIIT01 ABB Infinet to Infinet Transfer Module Bailey Infi 90","description":"\u003cp\u003eConfigured for serial communication transfer and node-to-node data routing in ABB Infi 90 networks, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB INIIT01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eINIIT01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInfinet to Infinet Transfer Module) provides direct electrical execution. The module transfers communication packets between Infi-Net segments through dual full-duplex EIA RS-232-C serial interfaces while maintaining deterministic loop communication timing across distributed system nodes.\u003c\/p\u003e\n\u003ch3\u003eModule Revision Information\u003c\/h3\u003e\n\u003cp\u003eThe INIIT01 is supplied as a dedicated transfer communication module for ABB Bailey Infi 90 systems. Available technical data does not define configurable suffix matrices or optional hardware subvariants for this module type.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eINIIT01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eInfinet to Infinet Transfer Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eBailey Infi 90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003e2 full duplex serial EIA RS-232-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Selectable Baud Rate\u003c\/td\u003e\n\u003ctd\u003e75 to 19,200 baud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Communication Rate\u003c\/td\u003e\n\u003ctd\u003e2 Mbaud or 10 Mbaud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003e128 kbytes processor RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Capability\u003c\/td\u003e\n\u003ctd\u003e62,500 system nodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNodes Per Loop\u003c\/td\u003e\n\u003ctd\u003e250 nodes per loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e0 % to 95 % up to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e7.6 x 33.0 x 17.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlace of Shipment\u003c\/td\u003e\n\u003ctd\u003eXiamen, China\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDependent on communication traffic loading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDeterministic Communication Architecture\u003c\/h3\u003e\n\u003cp\u003eThe INIIT01 module exchanges communication frames between interconnected Infi-Net loops using high-speed deterministic backplane synchronization. Internal transfer logic coordinates message routing between serial communication interfaces and distributed network nodes.\u003c\/p\u003e\n\u003cp\u003eBackplane communication timing is dependent on connector seating stability and electrical continuity across rack interfaces. Shield grounding consistency between cabinet sections assists in limiting communication retries caused by transient voltage differentials.\u003c\/p\u003e\n\u003cp\u003eThe module supports scalable network density through loop segmentation and distributed node assignment structures. Communication throughput is influenced by configured baud rate, loop loading, and serial interface utilization.\u003c\/p\u003e\n\u003ch3\u003eTechnical Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What serial communication standard is supported by the INIIT01?\u003cbr\u003eA: The module supports dual full duplex EIA RS-232-C serial communication interfaces.\u003c\/p\u003e\n\u003cp\u003eQ: Can the baud rate be adjusted by the user?\u003cbr\u003eA: Yes. User-selectable communication rates from 75 baud to 19,200 baud are supported through module configuration.\u003c\/p\u003e\n\u003cp\u003eQ: What network size can the module support?\u003cbr\u003eA: The documented system capability supports up to 62,500 system nodes with 250 nodes per communication loop.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module perform protocol conversion between external networks?\u003cbr\u003eA: The available technical data identifies the INIIT01 as an Infi-Net to Infi-Net transfer module for internal ABB communication routing.\u003c\/p\u003e\n\u003cp\u003eQ: What installation condition most affects communication stability?\u003cbr\u003eA: Improper grounding references, loose connector engagement, and routing serial communication wiring adjacent to high-current AC conductors may introduce communication transfer errors.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation and Wiring Practices\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInstall the module with rack power removed whenever maintenance procedures permit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify grounding continuity between communication cabinets before energizing the network loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute RS-232 communication wiring separately from motor control and AC feeder circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain proper connector insertion pressure during backplane installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse anti-static handling procedures during servicing and transportation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInspect edge connectors for contamination or contact deformation before installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain cabinet airflow conditions within specified ambient operating limits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIncluded Shipment Content\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eINIIT01 Infinet to Infinet Transfer Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAnti-static industrial protective packaging\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStandard transport cushioning materials\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOptional related hardware may include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eABB Infi 90 communication racks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInfi-Net interface assemblies\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCommunication extender modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLogistics and Delivery Information\u003c\/h3\u003e\n\u003cp\u003eDelivery time: 3-5 days when payment finish. International shipment available through DHL, FedEx, and UPS industrial logistics channels.\u003c\/p\u003e\n\u003cp\u003eProtective anti-static packaging and reinforced internal cushioning are applied to reduce connector vibration exposure and PCB handling stress during long-distance transportation.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021117608109,"sku":"INIIT01","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/INIIT01.jpg?v=1779952567","url":"https:\/\/www.maxwellplc.com\/products\/iniit01-abb-infinet-to-infinet-transfer-module-bailey-infi-90","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}