{"product_id":"inict13a-abb-infi-90-infi-net-to-computer-transfer-module","title":"INICT13A ABB Infi 90 Infi-Net to Computer Transfer Module","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB INICT13A\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eINICT13A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInfi-Net to Computer Transfer Module, operates as a dedicated hardware component for serial data translation and packet transfer within Infi 90 distributed control system networks.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eINICT13A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.36 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.5 x 32.5 x 17.8 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage Input\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTariff Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8538908180\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNetwork Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInfi-Net to Host Computer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBase Platform\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInfi 90 System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThis processing module interfaces directly with the system cabinet mounting slot, utilizing onboard logic to manage data packet scaling across the local backplane bus communication velocity channels. The module microprocessor decodes high-speed synchronous Infi-Net ring tokens and structures them into asynchronous serial frames compatible with host computer terminal endpoints. Internal firmware flash compatibility constraints dictate that the board revision must match existing node sub-loop controllers to maintain uniform macro-command execution times and prevent network buffer overruns during high traffic spikes.\u003c\/p\u003e\n\u003ch3\u003eCommon Engineering Inquiries\u003c\/h3\u003e\n\u003cp\u003eQ: What are the primary diagnostic indicators visible on the front faceplate?\u003c\/p\u003e\n\u003cp\u003eA: The faceplate contains standard status LEDs that display localized microprocessor execution states, Infi-Net ring synchronization status, and active transmit\/receive data sequences over the serial computer link.\u003c\/p\u003e\n\u003cp\u003eQ: Can this component undergo a hot-swap replacement during active system runtime?\u003c\/p\u003e\n\u003cp\u003eA: No. Removing or inserting this module while the system enclosure is energized introduces inductive voltage transients that can corrupt the token-ring network partition or cause localized backplane bus failures.\u003c\/p\u003e\n\u003cp\u003eQ: How is the node address configured on this specific hardware interface?\u003c\/p\u003e\n\u003cp\u003eA: Node address designation is handled via onboard dual-inline package (DIP) switch matrix configurations located on the primary printed circuit board before installation into the chassis slot.\u003c\/p\u003e\n\u003ch3\u003eComponent Deployment Parameters\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure the host rack power supply is completely isolated before inserting the card into the backplane guides.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse static dissipative wrist straps grounded directly to the metal enclosure frame during module configuration and handling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute the external serial interface cables away from high-voltage motor control center lines to avoid induced magnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify all retention screws are hand-tightened to maintain constant ground plane continuity between the module faceplate and the rack structure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackaging Allocations\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOne INICT13A interface module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated protective slot alignment rails\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eComponent registration documentation insert\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDispatch Details\u003c\/h3\u003e\n\u003cp\u003eDelivery time: 2-7 days when payment finish, routed via DHL\/FEDEX\/UPS global freight channels. The component ships enclosed inside tailored anti-static industrial packaging complete with dense custom foam inserts to absorb structural transit vibrations.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021160632493,"sku":"INICT13A","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/INICT13A-1.jpg?v=1779776337","url":"https:\/\/www.maxwellplc.com\/products\/inict13a-abb-infi-90-infi-net-to-computer-transfer-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}