{"product_id":"inddm01-abb-disk-drive-module-infi-90","title":"INDDM01 ABB Disk Drive Module Infi 90","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB INDDM01\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eINDDM01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDisk Drive Module, operates as a dedicated hardware component for localized data storage, historical logging, and system backup archiving within Infi 90 platforms. It executes low-level disk read\/write cycles to manage database configurations and system configuration parameters directly over the system backplane assembly.\u003c\/p\u003e\n\u003ch3\u003eTechnical Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eINDDM01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSWEDEN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.6 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e17.8 x 5.1 x 33.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to +55 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 A maximum at 5 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDrive Interfaces\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.5-inch floppy disk drive; 120-megabyte hard disk drive\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMemory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Mbyte RAM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 MHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication Rate\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 Mbaud\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Capability\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 30,000 database points typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpare Model Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6640930A1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTariff Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8537101190\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and System Firmware Integration\u003c\/h3\u003e\n\u003cp\u003eThe INDDM01 aligns directly with backplane bus communication velocity baselines to stream batch trends and localized database parameters without introducing bus latency. Onboard execution driven by a 100 MHz clock coordinates the data flow between the 8 Mbyte RAM block and the dual storage drives. Firmware flash compatibility is mandatory between this storage node and the primary processing controllers to guarantee that sequential database sector archiving cycles map into the 30,000 parameter registers without causing transaction dropouts or time-out faults on the active loop branch.\u003c\/p\u003e\n\u003ch3\u003eTechnical Queries and Engineering Review\u003c\/h3\u003e\n\u003cp\u003eQ: What are the technical constraints of the 4 A power demand on the system backplane?\u003c\/p\u003e\n\u003cp\u003eA: The module requires up to 4 A at 5 VDC from the shared backplane rails to spin up and drive the magnetic media storage units. Total power supply metrics inside the active chassis layer must account for this load to prevent common-mode voltage drops.\u003c\/p\u003e\n\u003cp\u003eQ: Can the physical 3.5-inch floppy media be inserted or removed during active operations?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the removable media can be cycled while powered, provided the local drive busy LED indicators are inactive. However, the complete INDDM01 module assembly itself must not be removed from the backplane under power.\u003c\/p\u003e\n\u003cp\u003eQ: Is hot-swapping of the complete module card supported in an active MMU slot?\u003c\/p\u003e\n\u003cp\u003eA: No. The backplane interfaces lack pre-charge pins. The slot power must be completely isolated before extracting or inserting the module card to protect the internal 8 Mbyte RAM and drive mechanics from data corruption and transient electrical damage.\u003c\/p\u003e\n\u003ch3\u003eOn-Site Installation Instructions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIsolate all input power links to the host chassis segment before allocating or pushing the module card into the slot.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure the physical card edges align flush into the plastic guide channels to prevent bending the rear connector array pins during insertion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute all communication external loop links away from electrical motor starters and variable speed drive cabling trays inside the common cabinet enclosure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTerminate all integrated cable shield drains directly to the main structural copper earth terminal plate inside the cabinet framing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipment Hardware Components\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x INDDM01 Disk Drive Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Anti-Static Shielding Pouch\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Component Verification Documentation Card\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackaging and Logistics Details\u003c\/h3\u003e\n\u003cp\u003eAll modules are enclosed within protective anti-static industrial packaging to neutralize electrical static variables. Consignments are distributed globally with typical transit times falling within 2-7 days when payment finish through DHL\/FEDEX\/UPS express carrier lines.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021115117741,"sku":"INDDM01","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/INDDM01.jpg?v=1779951678","url":"https:\/\/www.maxwellplc.com\/products\/inddm01-abb-disk-drive-module-infi-90","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}