{"product_id":"iepdp01-abb-power-distribution-panel-infi-90-system","title":"IEPDP01 ABB Power Distribution Panel Infi 90 System","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB IEPDP01\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIEPDP01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePower Distribution Panel, operates as a dedicated hardware component for centralized electrical branch routing within\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eInfi 90\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatforms. The unit acts as a physical termination layer that segments primary supply feeds into six independent outputs, managing load distribution while providing circuit protection for downstream rack components.\u003c\/p\u003e\n\u003ch3\u003eElectrical and Physical Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIEPDP01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSweden\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.8 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e48.3 x 10.2 x 7.6 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 to +60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive distribution panel (internal loss determined by circuit load)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 - 300 Vac\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 Amps max per terminal block position\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Quantity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection Fusing\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 x 20 mm glass cartridge fuses per branch circuit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGalvanic Isolation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 kV terminal-to-panel physical insulation rating\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Form\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard 19-inch rack enclosure layout\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRelative Humidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10% to 95% RH, non-condensing envelope\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to +85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eIn an integrated DCS layout, the IEPDP01 powers high-density processors and communication modems that rely on steady backplane bus communication velocity configurations. Maintaining continuous voltage paths directly limits thermal instability inside the rack enclosure, which preserves the timing windows needed for deterministic execution across internal lines. Clean load tracking prevents voltage sags that could cause synchronization timeouts or corrupt firmware flash compatibility sequences during automated system updates.\u003c\/p\u003e\n\u003ch3\u003eHardware Interface FAQ\u003c\/h3\u003e\n\u003cp\u003eQ: Does the IEPDP01 panel support hot-swap replacement of fuses while the branch circuit is live?\u003c\/p\u003e\n\u003cp\u003eA: Fuse extraction is physically possible using insulated fuse pullers, but removing a cartridge under active load will interrupt current to that specific branch. This action instantly drops power to all devices tied to that output line, which can disrupt real-time control communications.\u003c\/p\u003e\n\u003cp\u003eQ: What are the consequences of exceeding the 20 Amps maximum limit on an individual output terminal?\u003c\/p\u003e\n\u003cp\u003eA: Exceeding 20 Amps on a single terminal path causes excessive thermal stress on the internal busbars and terminal screws. This overload risks degrading the 2 kV terminal-to-panel isolation profile and can lead to premature structural failures or internal short circuits.\u003c\/p\u003e\n\u003cp\u003eQ: How does the 2 kV isolation rating affect standard system grounding layouts?\u003c\/p\u003e\n\u003cp\u003eA: The 2 kV terminal-to-panel isolation provides a high dielectric barrier between the electrical distribution circuits and the structural 19-inch mounting frame. This configuration prevents high-voltage field transients from grounding through the chassis, helping to protect sensitive signal logic layers in the system.\u003c\/p\u003e\n\u003ch3\u003eField Layout and Termination Directives\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRack Mounting Stability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSecure the chassis into standard 19-inch rack frames using four matching panel screws, verifying that the metal-to-metal interface provides a low-impedance connection to the enclosure earth grid.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Block Wiring Limits:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStrip branch wires according to standard specifications and insert them fully into the terminal plates, tightening the terminal screws to standard industrial torque parameters to prevent loose connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFuse Capacity Alignment:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVerify that the installed 5 x 20 mm glass cartridge fuses match the explicit overcurrent limits of the downstream load devices. Never bypass or jump a fuse terminal position.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Routing Segregation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRoute high-voltage AC distribution wires away from low-voltage I\/O and communication cables inside the cabinet to prevent capacitive noise coupling and maintain overall signal integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipment Packing Parameters\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStandard Contained Hardware:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOne ABB IEPDP01 19-inch rack-mount Power Distribution Panel assembly fitted with six active terminal positions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeparated Accessory Requirements:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndustrial branch fuses, external supply wiring, terminal boot insulators, and enclosure mounting screws must be ordered as separate lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLogistics Profile and Handling Data\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConsignment Processing Time:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDelivery time: 2-7 days when payment finish, routed via prioritized international express courier networks using DHL, FEDEX, or UPS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAnti-Static Industrial Packaging:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDispatched within heavy-duty anti-static industrial packaging and protected by internal foam end-caps to prevent chassis deformation or damage to terminal ceramic components during global transit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021143527597,"sku":"IEPDP01","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/IEPDP01_1.jpg?v=1780212383","url":"https:\/\/www.maxwellplc.com\/products\/iepdp01-abb-power-distribution-panel-infi-90-system","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}