{"product_id":"ic695pns001ca-general-electric-ic695pns001ca-abah-profinet-scanner-module","title":"IC695PNS001CA General Electric IC695PNS001CA-ABAH Profinet Scanner Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-164 citation-end-164\"\u003eThe GE IC695PNS001CA-ABAH is a sophisticated network interface module designed to integrate remote I\/O racks into a high-speed PROFINET ecosystem.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-163 citation-end-163\"\u003eEngineered specifically for the PACSystems RX3i architecture, this scanner serves as a bridge, allowing a central PROFINET Controller to manage remote Series 90-30 or RX3i I\/O modules over an Ethernet-based LAN.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIt functions by autonomously scanning the local rack and synchronizing input\/output data with the master controller at user-defined production rates.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-162 citation-end-162\"\u003eThis module is essential for distributed control architectures where real-time responsiveness and high-density data throughput are required across geographically dispersed equipment racks.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCore Network Capabilities and Hardware Architecture\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMulti-Port Switching:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures four integrated Ethernet ports supporting 10\/100\/1000 Mbps speeds, allowing for flexible copper and fiber optic connectivity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-161\"\u003e\u003c\/span\u003e\u003cstrong\u003eTopological Versatility:\u003c\/strong\u003e\u003cspan class=\"citation-161 citation-end-161\"\u003e\u003cspan\u003e \u003c\/span\u003eFully compatible with star, daisy-chain, and ring topologies, including support for Media Redundancy Protocol (MRP) to ensure system uptime during cable failure.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTool-Less Replacement:\u003c\/strong\u003e\u003cspan class=\"citation-160 citation-end-160\"\u003e\u003cspan\u003e \u003c\/span\u003eIncludes an SD card slot that stores the I\/O Device Name, allowing for rapid module swaps without the need for a specialized configuration PC.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnectivity Standards:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with a dedicated RJ-45 front-panel port for local firmware management and maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFail-Safe Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProgrammable I\/O default states ensure that field devices transition to a safe condition if network communication is interrupted.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel Revision\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIC695PNS001CA-ABAH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGeneral Electric (GE)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePhysical Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.52 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModule Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7 x 13.3 x 13.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNetwork Protocol\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePROFINET I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSoftware Requirement\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProficy Machine Edition (PME)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eStrategic Industrial Deployment Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe IC695PNS001CA-ABAH is a cornerstone for modernizing industrial networks and implementing distributed intelligence. Common applications include:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDistributed Manufacturing Lines:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLinking multiple assembly stations to a single RX3i controller via PROFINET, reducing wiring costs while maintaining millisecond-level synchronization.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWater and Wastewater Treatment:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eManaging remote pump stations and sensor clusters over long distances using fiber optic extensions supported by the module's high-speed ports.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant Infrastructure:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUtilizing Media Redundancy Protocol (MRP) in critical processing plants to ensure that a single broken Ethernet cable does not lead to a total system shutdown.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnergy Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrating remote power monitoring I\/O with central DCS platforms for real-time load balancing and historical data acquisition.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLegacy Migration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBridging existing Series 90-30 I\/O racks into newer RX3i PROFINET control networks, extending the lifecycle of established hardware investments.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45519075279021,"sku":"IC695PNS001CA-ABAH","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/general-electric-ic695pns001ca-abah-profinet-scanner-module-ubyzbf53off.jpg?v=1766986311","url":"https:\/\/www.maxwellplc.com\/products\/ic695pns001ca-general-electric-ic695pns001ca-abah-profinet-scanner-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}