{"product_id":"ic694mdl930-rx3i-8-point-isolated-relay-output-module-pacsystems-ge-fanuc","title":"IC694MDL930 RX3i 8-Point Isolated Relay Output Module PACSystems | GE Fanuc","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc IC694MDL930\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8-channel relay output module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePACSystems RX3i\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePLC racks. It provides dry-contact switching to interface the controller with field devices such as contactors, solenoids, alarms, and indicator lamps. Each output is an individually isolated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eForm A (normally open)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erelay contact with a dedicated common, allowing mixed-voltage circuits on the same module when correctly wired.\u003c\/p\u003e\n\u003cp\u003ePoint LEDs provide quick verification of output status during commissioning and troubleshooting. Field loads are powered externally; the module switches the load circuit through relay contacts.\u003c\/p\u003e\n\u003ch3\u003eSwitching and Electrical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModel Number: IC694MDL930\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Type: Isolated Relay Output Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Family: PACSystems RX3i\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutputs: 8 × relay outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContact Form: Form A, normally open (N.O.)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIsolation: Individual point isolation with separate commons\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVoltage Range:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e5–30 V DC (24 V DC nominal)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e5–250 V AC, 50\/60 Hz (120\/240 V AC nominal)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eCurrent Rating:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e4 A per point (resistive)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 A per point (pilot duty)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eMinimum Load: 10 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTypical Switching Response: 15 ms ON \/ 15 ms OFF\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModule Load Limit: Up to 30 A total for UL installations (derate with temperature)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDielectric Ratings: 250 VAC continuous, 1500 VAC for 60 seconds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndicators: 8 output status LEDs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower: Field power supplied externally (load side)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCondition: Brand new\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: Approx. 0.3 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: Approx. 3.5 × 13.2 × 13.5 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSystem: PLC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Status: Active\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCountry of Origin: USA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHS Code: 8537101190\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTypical Use Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe IC694MDL930 is used where relay isolation and broad voltage compatibility are required within an RX3i control system. Common applications include switching motor starter coils, interposing relays, solenoid valves, stack lights, horns, and alarm circuits in manufacturing automation, material handling, utilities, and process skids.\u003c\/p\u003e\n\u003cp\u003eIt is also used in retrofit projects to maintain existing relay-controlled field wiring while upgrading or servicing RX3i PLC racks.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Ge Fanuc","offers":[{"title":"Default Title","offer_id":45519057551533,"sku":"IC694MDL930","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/ge-fanuc-ic694mdl930-voltage-output-module-2uuzhxnbjet.jpg?v=1766985854","url":"https:\/\/www.maxwellplc.com\/products\/ic694mdl930-rx3i-8-point-isolated-relay-output-module-pacsystems-ge-fanuc","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}