{"product_id":"ic200pns001-ge-fanuc-versamax-profinet-scanner-network-interface-module","title":"IC200PNS001 GE Fanuc VersaMax PROFINET Scanner Network Interface Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc IC200PNS001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePROFINET scanner \/ network interface module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVersaMax\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edistributed I\/O systems. It connects a VersaMax I\/O station to a PROFINET network and manages cyclic I\/O data exchange, device diagnostics, and module configuration reporting. The unit is commonly used to integrate VersaMax remote I\/O into PLC architectures that use PROFINET, including systems built around compatible PACSystems controllers.\u003c\/p\u003e\n\u003cp\u003eWith dual Ethernet ports and an integrated switch function, the module supports flexible cabling layouts while requiring only a single IP configuration for the I\/O node.\u003c\/p\u003e\n\u003ch3\u003eKey Technical Characteristics\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProduct series: VersaMax\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModule type: PROFINET Scanner \/ Network Interface Unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePROFINET device profile: PROFINET I\/O Device (Slave) V2.2 Class A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEthernet interface:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e2 × RJ45 ports\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated 2-port switch (single IP address)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e10\/100 Mbps auto-negotiation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eSupported network layouts: line, star (via switch), and ring architectures (system dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eI\/O data capacity (cyclic exchange):\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eUp to 2880 bytes total\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1440 bytes input + 1440 bytes output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eDiagnostics and control data:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e32 diagnostic input status bits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e32 output control bits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eNode capacity: Supports up to 8 VersaMax I\/O modules and carriers per station\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUpdate time: Configurable 1 ms to 512 ms (application dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBackplane power: 5 VDC, approx. 3 W consumption\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCabling: 10\/100BASE-T, up to 100 m per copper segment (extendable with switches or media converters)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnvironmental: 0 to 60°C operation without forced-air cooling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSoftware\/firmware compatibility note\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTypically requires RX3i CPU firmware 7.0 or later and Proficy Machine Edition 7.0 or later (system dependent).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003ePhysical and commercial data\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: 13.3 × 13 × 6.8 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: 0.26 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCondition: Brand New\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAvailability: In Stock\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMOQ: 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOrigin: USA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct status: Active\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePROFINET-based distributed I\/O nodes using VersaMax hardware\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMachine automation lines requiring deterministic Ethernet I\/O updates\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePackaging, assembly, conveyors, and material handling systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModernization projects adding PROFINET connectivity while retaining VersaMax I\/O wiring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRemote diagnostics and fault reporting for I\/O islands in industrial networks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45519044837549,"sku":"IC200PNS001","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/ge-fanuc-ic200pns001-versamax-profinet-scanner-modules-h2msru5v2gg.jpg?v=1766985700","url":"https:\/\/www.maxwellplc.com\/products\/ic200pns001-ge-fanuc-versamax-profinet-scanner-network-interface-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}