{"product_id":"honeywell-mli-dr60su-base-module-brand-new-masterlogic-plc-i-o-base","title":"Honeywell MLI-DR60SU Base Module - Brand New MasterLogic PLC I\/O Base","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Honeywell MLI-DR60SU Base Module serves as the robust foundational backbone for scalable industrial control systems within the MasterLogic programming environment. Engineered to support high-density I\/O configurations, it accepts a wide range of universal input signals, simplifying sensor integration and minimizing complex wiring. System integrators and automation engineers rely on this module to build flexible, high-performance control architectures that handle everything from basic sequencing to complex networked applications. With built-in multi-communication capabilities, the MLI-DR60SU seamlessly exchanges data with HMIs, routers, and supervisory systems, delivering exceptional reliability for modern industrial automation.\u003c\/p\u003e\n\u003ch2\u003eCore Technical Advantages\u003c\/h2\u003e\n\u003cp\u003eHigh-Density Universal Integration\u003c\/p\u003e\n\u003cp\u003eThe module features 60 configurable channels that accept diverse voltage and current signals. This high-density architecture reduces cabinet space requirements and streamlines sensor connectivity in demanding industrial environments.\u003c\/p\u003e\n\u003cp\u003eScalable Architecture and Expansion\u003c\/p\u003e\n\u003cp\u003eThe base module supports expandable I\/O configurations, allowing systems to scale up to 254 I\/O points across seven stages. Users can add up to two expansion modules to achieve highly tailored network and control topologies without redesigning the core system.\u003c\/p\u003e\n\u003cp\u003eAdvanced MasterLogic Compatibility\u003c\/p\u003e\n\u003cp\u003eFully supported by the MasterLogic programming environment, the module executes complex instructions including advanced arithmetic, data processing, and trigonometric operations. It supports native communication protocols such as MLDP and Modbus to ensure seamless integration with existing Supervisory Control and Data Acquisition (SCADA) systems.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMLI-DR60SU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHONEYWELL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBase Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMasterLogic-50\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBrand New\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDistributed Control System (DCS) \/ PLC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupported Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e60 Configurable Universal Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Protocols\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEthernet, MLDP, Modbus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupported Expansion\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 2 Expansion Modules\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.4 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7 cm × 14 cm × 14.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHS Code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8537101190\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLifecycle Status\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eActive \/ Current\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eInstallation and Maintenance Guide\u003c\/h2\u003e\n\u003cp\u003eEnsure the module is mounted securely on a standard DIN rail within a clean, vibration-free control panel that meets the environmental operating specifications.\u003c\/p\u003e\n\u003cp\u003eConnect the power supply and grounding cables according to the standard MasterLogic wiring diagram. Verify that the grounding resistance is below 100 ohms to prevent electrical interference.\u003c\/p\u003e\n\u003cp\u003eConnect the Ethernet and field communication cables securely, ensuring that the cable bend radius is maintained at least four times the cable diameter to prevent signal degradation.\u003c\/p\u003e\n\u003cp\u003eVerify the input signals using the MasterLogic software before placing the module into full operation. Ensure the terminal blocks are fully locked and protected from ingress of dust and moisture.\u003c\/p\u003e\n\u003ch2\u003eWhy Choose This Model\u003c\/h2\u003e\n\u003cp\u003eThe Honeywell MLI-DR60SU provides a cost-effective and highly reliable solution for modernizing control systems. Its advanced hardware architecture minimizes signal loss, while the durable enclosure offers excellent thermal stability in standard industrial conditions. The native integration with the MasterLogic platform ensures long-term operational continuity, reducing maintenance efforts and downtime during system upgrades.\u003c\/p\u003e\n\u003ch2\u003eDelivery \u0026amp; Logistics\u003c\/h2\u003e\n\u003cp\u003eWe ship all items in brand-new, original sealed packaging with standard anti-static protection.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLead Time:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn Stock, ready to ship\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDelivery Time:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3 - 5 business days upon payment confirmation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShipping Carriers:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDHL, FedEx, UPS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003eQ1: What is the maximum number of I\/O points supported by this system configuration?\u003c\/p\u003e\n\u003cp\u003eA1: The MasterLogic architecture connected to the MLI-DR60SU supports up to 254 I\/O points across seven stages, allowing for significant scalability.\u003c\/p\u003e\n\u003cp\u003eQ2: Does the module support Modbus communication out of the box?\u003c\/p\u003e\n\u003cp\u003eA2: Yes, the module features built-in communication protocols including Modbus and MLDP for direct communication with HMIs and other network devices.\u003c\/p\u003e\n\u003cp\u003eQ3: Can this module be used in place of older Honeywell PLC units?\u003c\/p\u003e\n\u003cp\u003eA3: The MLI-DR60SU is designed to be compatible with the MasterLogic-50 platform, providing a reliable, direct replacement or upgrade path for older modules.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45518957052077,"sku":"MLI‐DR60SU","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/honeywell-mli-dr60su-base-module-4qe5uhxfrxa.jpg?v=1766982960","url":"https:\/\/www.maxwellplc.com\/products\/honeywell-mli-dr60su-base-module-brand-new-masterlogic-plc-i-o-base","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}