{"product_id":"honeywell-mlf-rd04a-rtd-input-module-high-precision-temperature-measurement-for-dcs","title":"Honeywell MLF-RD04A RTD Input Module – High-Precision Temperature Measurement for DCS","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Honeywell MLF-RD04A RTD Input Module delivers high-accuracy temperature measurement for mission-critical industrial automation systems. Engineered for seamless integration with Experion PKS and other DCS platforms, it acquires and processes resistance temperature detector signals with exceptional stability and repeatability. This module ensures precise thermal monitoring of turbines, compressors, reactors, and safety instrumented systems where temperature excursions can compromise safety and product quality. Its advanced signal conditioning eliminates noise and drift, providing reliable data for control, protection, and compliance reporting in demanding process environments.\u003c\/p\u003e\n\u003ch2\u003eSignal Acquisition Architecture \u0026amp; Measurement Accuracy\u003c\/h2\u003e\n\u003cp\u003eThe MLF-RD04A employs a 16-bit analog-to-digital converter with digital filtering to capture minute resistance changes in RTD elements. It supports Pt100, Pt200, and Pt500 sensors with 2-, 3-, and 4-wire configurations, automatically compensating for lead resistance to maintain accuracy. Galvanic isolation between input channels and system logic protects against ground loops and transient surges. Continuous self-diagnostics monitor sensor integrity, detecting open circuits, short circuits, and out-of-range conditions in real time.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\n\u003cp\u003eSpecification\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eValue\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eManufacturer\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eHoneywell International\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCountry of Origin\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eUnited States\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.55 kg\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eShipping Dimensions\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e180 × 120 × 45 mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eInput Type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRTD (Pt100, Pt200, Pt500)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNumber of Channels\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4 differential\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAccuracy\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e±0.1°C typical\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMeasurement Range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-200°C to +850°C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating Temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-20°C to +70°C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eProtection Rating\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIP20\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eHS Code\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e90303390\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eInstallation \u0026amp; Sensor Wiring Guidance\u003c\/h2\u003e\n\u003cp\u003eMount the MLF-RD04A in a grounded DCS rack within an EMI-shielded enclosure. Use twisted-pair cabling for RTD connections, routing away from high-voltage conductors. Maintain proper wire gauge and terminal torque to prevent contact resistance errors. For 3- and 4-wire RTDs, ensure consistent wiring lengths to preserve lead compensation accuracy. Perform loop checks with a calibrated simulator before commissioning to validate channel response across the full measurement range.\u003c\/p\u003e\n\u003ch2\u003eExtreme Environment Performance \u0026amp; System Integration\u003c\/h2\u003e\n\u003cp\u003eProven in offshore platforms, chemical processing plants, and power generation facilities, the MLF-RD04A maintains measurement integrity under vibration, temperature cycling, and corrosive atmospheres. Its conformal-coated circuitry resists moisture and chemical ingress, while gold-plated terminals ensure long-term connectivity. Full interoperability with Honeywell TSI and safety systems enables synchronized thermal protection and process control, reducing engineering complexity and lifecycle costs.\u003c\/p\u003e\n\u003ch2\u003eOrdering Info\u003c\/h2\u003e\n\u003cp\u003e(1) 1 × Honeywell MLF-RD04A RTD Input Module (factory sealed)\u003c\/p\u003e\n\u003cp\u003e(2) 1 × Installation and configuration guide\u003c\/p\u003e\n\u003cp\u003e(3) 1 × Calibration certificate and compliance documentation\u003c\/p\u003e\n\u003cp\u003e(4) Anti-static protective packaging\u003c\/p\u003e\n\u003ch2\u003eGlobal Dispatch \u0026amp; Secure Logistics\u003c\/h2\u003e\n\u003cp\u003eOrders ship within 2–7 days of payment clearance via DHL, FedEx, or UPS with full tracking enabled. Each module is encased in anti-static industrial packaging with reinforced outer cartons to withstand global transit. Serialized shipping documents ensure traceability from warehouse to installation site.\u003c\/p\u003e\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDoes the MLF-RD04A support both 3-wire and 4-wire RTD configurations?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, it supports 2-, 3-, and 4-wire RTDs with automatic lead compensation for maximum accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCan this module be used in hazardous area applications?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA2:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen installed in a certified explosion-proof enclosure with appropriate barriers, it meets hazardous area requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhat is the typical update rate per channel?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA3:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEach channel updates every 100 milliseconds, ensuring responsive temperature monitoring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIs cold junction compensation required for RTD measurements?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA4:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo, RTD measurements do not require cold junction compensation; the module measures absolute resistance dir\u003cspan\u003ee\u003c\/span\u003e\u003cspan\u003ec\u003c\/span\u003e\u003cspan\u003et\u003c\/span\u003e\u003cspan\u003el\u003c\/span\u003e\u003cspan\u003ey\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45518942077101,"sku":"MLF-RD04A","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/honeywell-mlf-rd04a-rtd-input-module-msaukmy5odr.jpg?v=1766982482","url":"https:\/\/www.maxwellplc.com\/products\/honeywell-mlf-rd04a-rtd-input-module-high-precision-temperature-measurement-for-dcs","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}