{"product_id":"honeywell-mle-dr16a-16-channel-contact-digital-input-module","title":"Honeywell MLE-DR16A 16-Channel Contact Digital Input Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Honeywell MLE-DR16A stands as a high-integrity sensing interface designed for the Master Logic programmable controller series. This 16-channel digital input module serves as the critical eyes of the DCS\/PLC system, translating discrete field signals from limit switches, pushbuttons, and proximity sensors into precise digital logic. Engineered for the rigors of heavy industrial environments, the MLE-DR16A effectively filters electrical noise and debounces mechanical contacts to prevent false triggering in high-speed process loops. Its primary value lies in its exceptional galvanic isolation and rapid response times, ensuring that critical status changes in safety-related or operational machinery are communicated to the CPU with millisecond accuracy. Whether deployed in power generation, oil and gas, or large-scale manufacturing, this module provides the robust stability required for uninterrupted plant monitoring.\u003c\/p\u003e\n\u003ch2\u003eInput Architecture and Logic Interface\u003c\/h2\u003e\n\u003cp\u003eThe MLE-DR16A utilizes a sophisticated optocoupler isolation barrier for every channel, protecting the internal system backplane from field-side transients and potential ground loops. Each of the 16 inputs features a dedicated status LED on the front panel, allowing maintenance personnel to perform instantaneous visual audits of field device states. The module hardware supports a 24VDC nominal input voltage, a standard in industrial control, and incorporates built-in digital filtering to manage signal jitter. This architecture ensures that the transition from \"Off\" to \"On\" state is captured definitively, facilitating precise sequence-of-events (SOE) recording when integrated into a broader Honeywell Experion or Master Logic environment.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMLE-DR16A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRated Input Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 4mA per Channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOptocoupler Isolation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStatus Display\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLED per Input Point\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to +55°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.4 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.0 x 14.0 x 14.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA \/ South Korea\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHS Code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8537101190\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eField Engineering \u0026amp; Wiring Standards\u003c\/h2\u003e\n\u003cp\u003eFor optimal performance, engineers must adhere to high-standard wiring practices. Use twisted-pair copper conductors for all field-side sensing loops to minimize electromagnetic interference (EMI). The MLE-DR16A requires a stable 24VDC external power source for the input circuits; verify that voltage drops across long cable runs do not fall below the module’s \"On\" threshold (typically 19VDC). Ensure the common (COM) terminal is properly referenced to the system's instrumentation ground to maintain a clean return path. When integrating into a cabinet with high-voltage motor starters, maintain a minimum 50mm separation between signal and power cabling to ensure the integrity of the discrete logic sensing.\u003c\/p\u003e\n\u003ch2\u003eEngineering Advantages and Resilience\u003c\/h2\u003e\n\u003cp\u003eThe MLE-DR16A excels in high-vibration and thermally volatile environments. Its solid-state design eliminates the failure points found in mechanical switching interfaces, providing a nearly infinite MTBF (Mean Time Between Failures). Within a Honeywell architecture, the module achieves seamless integration with Experion PKS platforms, allowing for centralized configuration and diagnostic reporting. This synergy reduces commissioning time and simplifies long-term maintenance by providing detailed error-reporting for the I\/O bus. The module's low power consumption profile further enhances its value in remote RTU cabinets where thermal management and energy efficiency are paramount.\u003c\/p\u003e\n\u003ch2\u003eDelivery Information\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDelivery time:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3-5 days when payment finish, BY DHL\/FEDEX\/UPS.\u003c\/p\u003e\n\u003cp\u003eEvery MLE-DR16A is shipped in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eanti-static industrial packaging\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand original Honeywell factory-sealed boxes. We guarantee the \"Brand New\" condition of the hardware, ensuring factory-calibration integrity remains intact upon arrival.\u003c\/p\u003e\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can the MLE-DR16A be used with AC input signals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: No. The MLE-DR16A is specifically designed for 24VDC logic. To sense AC signals, an interposing relay or a dedicated AC input module (such as the MLE-AR series) must be utilized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What is the maximum cable length supported for a 24VDC input?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: While the module is highly sensitive, we recommend keeping signal cable runs under 300 meters. For longer distances, evaluate the voltage drop and use a larger wire gauge to ensure the input current remains at a detectable level.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Does this module support Sequence of Events (SOE) recording?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: Yes. When paired with a compatible Honeywell Master Logic CPU and configured within the engineering environment, the MLE-DR16A supports millisecond-accurate event logging for fault analysis.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Is the terminal block removable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA4: Most Honeywell Master Logic I\/O modules, including the MLE-DR16A, feature a removable terminal block to allow for \"pre-wiring\" and to simplify module replacement without disturbing the field wiring.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45518952759469,"sku":"MLE-DR16A","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/honeywell-mle-dr16a-digital-input-module-gio1wgvdonc.jpg?v=1766982826","url":"https:\/\/www.maxwellplc.com\/products\/honeywell-mle-dr16a-16-channel-contact-digital-input-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}