{"product_id":"honeywell-mle-dc16a-digital-input-expansion-module","title":"Honeywell MLE-DC16A Digital Input Expansion Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Honeywell MLE-DC16A Digital Input Expansion Module delivers high-density, reliable discrete signal processing for demanding industrial automation and distributed control networks. Engineering teams deploy this premium 16-channel expansion unit within Honeywell Experion systems to monitor critical contact states, limit switches, and field relays in real time. By providing high-speed optical isolation across all field channels, the MLE-DC16A protects core processor backplanes from volatile field-side electrical surges and ground loops. It excels in heavy industrial environments like continuous chemical manufacturing, emergency shutdown systems (ESD), and high-vibration power generation facilities. This module ensures absolute operational continuity by eliminating signal chatter and providing precise, jitter-free binary state detection under volatile operating conditions.\u003c\/p\u003e\n\u003ch2\u003eAdvanced Input Processing and Bus Integration\u003c\/h2\u003e\n\u003cp\u003eThe MLE-DC16A utilizes a dedicated hardware processing layout featuring independent input filtering circuits on every channel to eliminate mechanical switch bounce and electromagnetic interference. The module communicates natively across high-speed internal backplane buses, ensuring that discrete state changes register at the controller level within milliseconds.\u003c\/p\u003e\n\u003cp\u003eIntegrated optical couplers establish a 2500V DC isolation barrier between the field-side wiring terminals and the sensitive logic circuits of the host processor rack. The internal firmware continuously executes hardware-level diagnostics, tracking input line resistance, voltage stability, and individual channel health. This proactive diagnostic layer transmits status flags instantly to the supervisory control system, allowing maintenance teams to identify broken field loops or failing field contacts before they trigger a system-wide trip.\u003c\/p\u003e\n\u003ch2\u003eDiscrete Input and Environmental Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFunctional Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCertified Engineering Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel Identifier\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMLE-DC16A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCountry of Origin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHarmonized System (HS) Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85389091\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePhysical Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.85 kg (1.87 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e220 mm x 140 mm x 85 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Isolated Digital Inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNominal Input Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24V DC (True Range: 18V to 30V DC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOff-State Voltage Threshold\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLess than 5V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOn-State Current Metric\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.2 mA @ 24V DC Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInternal Hardware Filter Delay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConfigurable from 1 ms to 20 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20°C to +65°C (-4°F to 149°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIngress Protection Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 Open Architecture Hardware\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eField Wiring and Enclosure Setup Guide\u003c\/h2\u003e\n\u003cp\u003eMount the MLE-DC16A module onto the standard terminal base or backplane carrier inside a dust-free, NEMA 4 or IP54 rated control cabinet to avoid moisture accumulation. Verify that adjacent module spacing leaves at least a 40mm thermal pocket to support unrestricted vertical airflow and maintain normal internal operating temperatures.\u003c\/p\u003e\n\u003cp\u003eTerminate field loops using shielded, twisted-pair cables with a wire cross-section between 16 AWG and 22 AWG, striping back insulation exactly 6mm. Route high-voltage AC power conductors away from the low-voltage DC input bundles inside the wire trays to prevent capacitive noise injection. Connect the master cable shield wires directly to the dedicated cabinet earth bar using a single-point grounding configuration to maximize electrical noise immunity.\u003c\/p\u003e\n\u003ch2\u003eArchitectural Resiliency and Integration Benefits\u003c\/h2\u003e\n\u003cp\u003eThe MLE-DC16A displays remarkable environmental durability, functioning without data loss across wide ambient temperature variations and harsh corrosive air environments. A premium G3-class conformal coating shields the surface-mount component traces from airborne sulfur, high humidity, and conductive metallic dust.\u003c\/p\u003e\n\u003cp\u003eThe expansion hardware synchronizes directly with the Honeywell Experion PKS platform, appearing automatically in the system hardware tree upon physical installation. This plug-and-play architecture allows rapid logic mapping within the Control Builder environment, enabling engineers to tie expanded inputs to interlocking logic and alarm systems without applying custom firmware patches or complex communication drivers.\u003c\/p\u003e\n\u003ch2\u003ePacking Manifest and Procurement Data\u003c\/h2\u003e\n\u003cp\u003eYour industrial expansion hardware ships directly from our logistics terminal fully certified, calibrated, and prepared for immediate panel commissioning. Each box contains:\u003c\/p\u003e\n\u003cp\u003e(1) New Original Honeywell MLE-DC16A Digital Input Expansion Module\u003c\/p\u003e\n\u003cp\u003e(2) Removable Factory Terminal Block Unit with Integrated Retention Screws\u003c\/p\u003e\n\u003cp\u003e(3) Serialized Quality Assurance and Manufacturer Compliance Certificate\u003c\/p\u003e\n\u003cp\u003e(4) Hardcopy I\/O Wiring and Terminal Assignment Diagram\u003c\/p\u003e\n\u003ch2\u003eFreight Logistics and Packaging Standard\u003c\/h2\u003e\n\u003cp\u003eOur fulfillment center completes international dispatch processing within 2-7 days when payment finish, utilizing premier express air couriers including DHL, FEDEX, and UPS for rapid worldwide delivery. We package every digital input module inside multi-layer anti-static industrial packaging and surround it with precision-cut, high-density shock-absorbing foam. This extra protection minimizes structural vibration during air freight transit, insulates sensitive internal microcontrollers against electrostatic discharge (ESD), and ensures your hardware arrives safely at the project site.\u003c\/p\u003e\n\u003ch2\u003eDiscrete Module Operational FAQs\u003c\/h2\u003e\n\u003cp\u003eQ1: Does the MLE-DC16A support dry-contact input loops, or does it require externally powered wet contacts?\u003c\/p\u003e\n\u003cp\u003eA1: The module supports both configurations, but it is optimized for 24V DC wet contacts. When implementing dry-contact monitoring, connect an external, regulated 24V DC power loop through the common terminal to provide the necessary wetting current for positive state changes.\u003c\/p\u003e\n\u003cp\u003eQ2: How does the configurable hardware filter delay help stabilize noisy field loops?\u003c\/p\u003e\n\u003cp\u003eA2: Mechanical contacts on heavy valves or pressure switches frequently bounce during transition, creating false binary cycles. Setting the input filter delay to a slightly higher value (e.g., 10 ms) forces the module to verify the state remains solid before pushing the update to the processor, filtering out transient spikes.\u003c\/p\u003e\n\u003cp\u003eQ3: Can an individual input channel be replaced if it experiences an electrical failure in the field?\u003c\/p\u003e\n\u003cp\u003eA3: The 16 input channels are integrated onto a single high-efficiency circuit board. If a specific channel suffers catastrophic over-voltage failure, move the field wire to an unused spare channel on the module and re-map the address in your Experion configuration software.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45518939488429,"sku":"MLE−DC16A","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/honeywell-mle-dc16a-digital-input-expansion-module-jkvzornzsxc.jpg?v=1766982389","url":"https:\/\/www.maxwellplc.com\/products\/honeywell-mle-dc16a-digital-input-expansion-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}