{"product_id":"honeywell-k2lcn-8-51401551-801-local-control-network-interface-module","title":"Honeywell K2LCN-8 51401551-801 Local Control Network Interface Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Honeywell K2LCN-8 51401551-801 serves as a high-performance Local Control Network (LCN) interface module designed specifically for mature TDC 3000 legacy architectures and modern cross-platform integrations. This critical hardware component establishes ultra-reliable, real-time deterministic communication between network nodes, ensuring continuous data synchronization across distributed control systems. Engineered for high-availability process environments like oil refining, chemical processing, and power generation, the module eliminates data bottlenecks and communication jitter. Its robust processing architecture guarantees steady execution of control strategies, preventing unexpected downtime and securing asset protection in complex thermal and chemical operations.\u003c\/p\u003e\n\u003ch2\u003eArchitecture and Network Capability\u003c\/h2\u003e\n\u003cp\u003eThis communication board utilizes a proprietary dedicated coprocessor system designed to offload high-speed token-pass ring calculations from the primary node processor. It fully supports Honeywell TotalPlant Solution (TPS) and TDC 3000 LCN coax network infrastructures, delivering native redundant media attachment units. The module manages dual-channel redundant physical layers seamlessly, executing automatic sub-millisecond switchovers if a primary cable segment degrades. This hardware generation utilizes upgraded onboard memory buffers to prevent frame loss during heavy network traffic bursts, providing backward compatibility with older K1LCN form factors while delivering superior electromagnetic interference resistance.\u003c\/p\u003e\n\u003ch2\u003eCritical Physical and Operational Data\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Metric Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eK2LCN-8 \/ 51401551-801\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCountry of Origin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNet Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.35 kg (2.98 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e310 mm x 220 mm x 45 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHousing Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndustrial Grade Aluminum \/ FR4 PCB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHS Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85176200\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNetwork Topology\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eToken-Pass Ring\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMedia Redundancy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual-Channel Coaxial Redundancy\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.1 A @ 5 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 °C (32 to 140 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRelative Humidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5% to 95% Non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eField Deployment and On-Site Integration\u003c\/h2\u003e\n\u003cp\u003eEngineers must insert this module into a powered-down card file slot dedicated to LCN node control. Before insertion, verify the physical address jumpers or dip switches on the board match the precise node layout designated in your system topology documentation. Ensure the coaxial transceiver connectors match standard network impedance requirements (typically 75 Ohms) to avoid signal reflection issues. Tighten all faceplate retention screws firmly to guarantee a solid chassis ground connection, protecting the internal electronics from static buildup. Check the status LEDs immediately upon system boot to confirm the module successfully passes its internal Power-On Self-Test (POST) and attaches to the active token ring.\u003c\/p\u003e\n\u003ch2\u003eOperational Strengths in Demanding Environments\u003c\/h2\u003e\n\u003cp\u003eThe 51401551-801 thrives in extreme industrial environments, featuring conformal coating on critical component traces to resist airborne corrosive elements like hydrogen sulfide and moisture. Its deterministic communication protocol guarantees precise message delivery windows, an absolute necessity when interfacing with safety-critical systems or complex turbine supervisory instrumentation. By retaining perfect software compatibility with Experion LCN bridges, plant managers can execute seamless control system migrations without rewriting foundational database configurations, significantly reducing risk and keeping legacy control assets fully operational.\u003c\/p\u003e\n\u003ch2\u003ePackage Manifest\u003c\/h2\u003e\n\u003cp\u003eEach ordered shipment contains the following components:\u003c\/p\u003e\n\u003cp\u003e(1) Original Honeywell K2LCN-8 51401551-801 Module\u003c\/p\u003e\n\u003cp\u003e(2) Factory Certificate of Conformance and Original Test Report\u003c\/p\u003e\n\u003cp\u003e(3) Protective Card Slot Guide Rails\u003c\/p\u003e\n\u003cp\u003e(4) Anti-Static Shielding Installation Cover\u003c\/p\u003e\n\u003ch2\u003eLogistics and Packaging Standards\u003c\/h2\u003e\n\u003cp\u003eYour shipment dispatches within 2-7 days when payment finish. Every order leaves our facility inside heavy-duty anti-static industrial packaging, utilizing custom-molded ESD foam inserts to prevent physical shock damage during global transit. We ship exclusively via premium air couriers including DHL, FEDEX, and UPS to guarantee fast, tracked, and secure delivery to your facility or job site.\u003c\/p\u003e\n\u003ch2\u003eNetwork Module Field Support\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eQ1: How does the K2LCN-8 handle a sudden failure on one of the redundant coaxial cables?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA1: The hardware features autonomous dual-channel media monitoring that instantly switches data traffic to the secondary channel without processor intervention or loss of control packets, logging a diagnostic alarm simultaneously.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eQ2: Can this board replace an older 51401551-101 module directly in an existing card file?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA2: Yes, the K2LCN-8 51401551-801 provides direct backward compatibility in terms of slot form factor and electrical specifications, though firmware version verification within your system software is recommended.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eQ3: What specific diagnostic indicator confirms the module has joined the active network ring?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA3: The front faceplate status indicators display a solid green light pattern once the module successfully completes its internal memory diagnostics and receives the network token pass validation.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45518930804909,"sku":"51401551-801","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/honeywell-k2lcn-8-51401551-801-local-control-network-module-hyvo0mux13k.jpg?v=1766982100","url":"https:\/\/www.maxwellplc.com\/products\/honeywell-k2lcn-8-51401551-801-local-control-network-interface-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}