{"product_id":"honeywell-gn-krr011-51204147-001-high-speed-fiber-optic-cable-assembly","title":"Honeywell GN-KRR011 51204147-001 High-Speed Fiber Optic Cable Assembly","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell GN-KRR011 (Part Number 51204147-001)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-integrity fiber optic cable assembly engineered specifically for the demanding communication backbones of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExperion PKS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTDC 3000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDCS environments. In modern industrial complexes, electromagnetic interference (EMI) and lightning surges pose significant risks to copper-based data lines; this fiber optic solution provides total electrical isolation and lightning-fast data throughput. It excels in long-distance inter-cabinet links, connecting Remote I\/O racks to central processing units without signal degradation. Whether utilized in offshore oil platforms or high-voltage power substations, the GN-KRR011 ensures that mission-critical process data and emergency shutdown commands move with absolute fidelity and zero latency, safeguarding both operational uptime and plant personnel.\u003c\/p\u003e\n\u003ch2\u003eOptical Architecture and Transmission Logic\u003c\/h2\u003e\n\u003cp\u003eThis cable assembly utilizes a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emulti-mode fiber core\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoptimized for short-to-medium range industrial distances, maintaining high bandwidth for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell I\/O Link\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand High-Speed Ethernet (HSE) protocols. The 51204147-001 features precision-polished connectors that minimize insertion loss and back-reflection, which is vital for the sensitivity of optical transceivers in C300 and C200 controllers. The outer jacket is constructed from specialized flame-retardant materials, providing resilience against chemical exposure and mechanical stress typical of industrial cable trays. Unlike standard commercial fiber, this assembly is designed with reinforced strain relief at the connector interface, preventing micro-fractures in the glass core that can lead to intermittent \"Communication Lost\" alarms during routine maintenance or cabinet vibrations.\u003c\/p\u003e\n\u003ch2\u003eCritical Infrastructure Parameters\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGN-KRR011\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51204147-001\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDuplex Multi-mode Fiber Optic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDCS Cabinet Interconnect \/ Remote I\/O Link\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40°C to +85°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndustrial Standard (Matched for Honeywell Transceivers)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.65 kg (Dependent on length)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Dimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30cm x 30cm x 5cm (Coiled)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHS Code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85447000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eField Routing and Handling Protocol\u003c\/h2\u003e\n\u003cp\u003eWhen deploying the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGN-KRR011\u003c\/strong\u003e, engineers must strictly adhere to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eminimum bend radius\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003especifications to prevent signal attenuation or permanent core damage. Avoid routing fiber optic lines alongside sharp metal edges or heavy power cables that may exert crushing force. During installation, always keep the protective dust caps in place until the moment of connection; even microscopic dust particles on the connector face can cause significant DB loss and trigger \"Link Error\" states. We recommend cleaning the connector tips with an industrial-grade fiber cleaner before insertion into the optical module. For vertical runs, ensure the cable is properly supported to prevent the weight of the assembly from causing mechanical tension on the transceiver ports.\u003c\/p\u003e\n\u003ch2\u003eEngineering Advantages in Hostile Environments\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e51204147-001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the preferred choice for facilities implementing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTurbine Supervisory Instrumentation (TSI)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand high-speed motor control where electrical noise is extreme. By utilizing an optical medium, this cable completely bypasses the ground loop issues that often plague copper installations in large-scale refineries. It facilitates a robust\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFTE (Fault Tolerant Ethernet)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einfrastructure, allowing for physical separation of redundant communication paths to ensure the control system survives localized fires or mechanical failures. Its wide temperature rating ensures reliable performance in unconditioned remote instrument enclosures (RIEs), making it a cornerstone for resilient\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIndustry 4.0\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econnectivity in the global B2B automation sector.\u003c\/p\u003e\n\u003ch2\u003eOrder Fulfillment and Global Dispatch\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eLogistics Timeline:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eShipping is initiated within 3-5 days when payment finish.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCarrier Network:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAll orders are handled by\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDHL, FEDEX, or UPS\u003c\/strong\u003e, providing tracked and insured delivery to your site.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEvery cable is coiled to prevent stress and enclosed in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eanti-static industrial packaging\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith moisture-sealed barriers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVerified Inventory:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWe supply exclusively\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNew, Sealed, and Original Pack\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunits. Every GN-KRR011 is batch-tested and visually inspected to ensure it meets Honeywell's stringent optical performance standards for immediate field commissioning.\u003c\/p\u003e\n\u003ch2\u003eConnectivity Intelligence FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can I use the GN-KRR011 to replace a standard copper I\/O Link cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. This is a fiber optic assembly and requires compatible optical transceiver modules (SFPs or dedicated fiber cards) on both ends of the link. It is not electrically compatible with copper ports.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What is the significance of the 51204147-001 part number?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA2:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis part number specifies the exact length and connector configuration approved for Honeywell DCS racks. Using non-approved part numbers can lead to signal impedance mismatches and unstable communication.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Is this cable rated for outdoor direct burial?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA3:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. The GN-KRR011 is designed for indoor industrial use or installation within conduits and cable trays. For direct burial, an additional armored outer jacket or protective conduit is required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: How do I troubleshoot a \"Weak Signal\" alarm on a fiber link?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA4:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFirst, clean the connector faces using a dry fiber cleaner. If the error persists, check for tight bends in the cable path or use an OTDR (Optical Time-Domain Reflectometer) to identify potential breaks or stress points along the assembly.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45518948303021,"sku":"51204147-001","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/honeywell-gn-krr011-51204147-001-fiber-optic-cable-jxn4vjub2px.jpg?v=1766982640","url":"https:\/\/www.maxwellplc.com\/products\/honeywell-gn-krr011-51204147-001-high-speed-fiber-optic-cable-assembly","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}