{"product_id":"honeywell-cv-opcsae-event-server-cai-industrial-opc-alarm-event-data-server","title":"Honeywell CV-OPCSAE Event Server CAI – Industrial OPC Alarm \u0026 Event Data Server","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Honeywell CV-OPCSAE Event Server CAI provides a robust, standardized interface for collecting, managing, and distributing alarm and event data across industrial automation networks. Fully compliant with OPC Alarm \u0026amp; Event specifications, it consolidates alerts from Experion PKS, PlantCruise, and other control platforms into a unified data stream for operators, engineers, and enterprise applications. Its deterministic processing ensures low-latency notification delivery, enabling rapid response to abnormal process conditions. By bridging real-time control systems with higher-level MES, ERP, and analytics platforms, the CV-OPCSAE strengthens operational awareness and supports proactive incident management.\u003c\/p\u003e\n\u003ch2\u003eEvent Processing Architecture \u0026amp; OPC Integration\u003c\/h2\u003e\n\u003cp\u003eThe CV-OPCSAE leverages a dedicated event processing engine capable of handling thousands of alarms per second without data loss. It supports multiple concurrent OPC A\u0026amp;E client connections, allowing simultaneous consumption by diverse applications. Intelligent filtering and prioritization logic ensure that critical alarms reach operators instantly while suppressing unnecessary chatter. Native integration with Honeywell control systems preserves contextual data—such as tag names, timestamps, and priority levels—ensuring downstream applications receive complete, actionable information.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\n\u003cp\u003eSpecification\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eValue\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eManufacturer\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eHoneywell International\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCountry of Origin\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eUnited States\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.35 kg\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eShipping Dimensions\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e18 × 14 × 4 cm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eSupported Protocols\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOPC Alarm \u0026amp; Events (OPC A\u0026amp;E)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConcurrent Client Connections\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eUp to 25\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eEvent Throughput\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e≥ 1,000 events\/sec\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating Temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0°C to +55°C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eProtection Rating\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIP20\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eHS Code\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e85176239\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eDeployment \u0026amp; Software Configuration Guidance\u003c\/h2\u003e\n\u003cp\u003eInstall the CV-OPCSAE on a secure Windows Server platform connected to the control system network. Configure OPC client subscriptions based on alarm priority, area, or process unit to optimize network load. Implement role-based access control to restrict event data access to authorized personnel. Regularly archive event logs and back up configuration settings to ensure quick recovery in case of system upgrades or migrations.\u003c\/p\u003e\n\u003ch2\u003eOperational Resilience \u0026amp; System Compatibility\u003c\/h2\u003e\n\u003cp\u003eDeployed in oil refineries, chemical plants, and power generation facilities, the CV-OPCSAE performs reliably under high event loads and fluctuating network conditions. Its software architecture tolerates temporary communication interruptions, resynchronizing seamlessly once connectivity is restored. Full interoperability with Honeywell’s TSI, safety instrumented systems, and advanced process control platforms ensures consistent alarm handling across the entire automation ecosystem.\u003c\/p\u003e\n\u003ch2\u003eOrdering Info\u003c\/h2\u003e\n\u003cp\u003e(1) 1 × Honeywell CV-OPCSAE Event Server CAI (factory sealed)\u003c\/p\u003e\n\u003cp\u003e(2) 1 × Software license authorization certificate\u003c\/p\u003e\n\u003cp\u003e(3) 1 × Installation and configuration guide\u003c\/p\u003e\n\u003cp\u003e(4) Anti-static protective packaging with authenticity seal\u003c\/p\u003e\n\u003ch2\u003eGlobal Dispatch \u0026amp; Secure Logistics\u003c\/h2\u003e\n\u003cp\u003eOrders ship within 2–7 days of payment clearance via DHL, FedEx, or UPS with complete shipment tracking. Each unit is securely packaged in anti-static materials inside reinforced cartons to withstand international shipping. Serialized documentation guarantees traceability from Honeywell’s facility to your installation site.\u003c\/p\u003e\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDoes the CV-OPCSAE support OPC UA Alarm \u0026amp; Condition models?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo, this model supports OPC Classic A\u0026amp;E; OPC UA requires separate Honeywell UA-compliant modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCan event data be filtered before sending to clients?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA2:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, filtering rules can be configured by priority, source, or category to reduce network traffic and focus operator attention.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhat is the maximum historical event retention period?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA3:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRetention depends on the connected historian’s capacity; the server itself does not impose fixed storage limits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIs real-time alarm acknowledgment supported through this server?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA4:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, authorized clients can acknowledge alarms directly via the OPC A\u0026amp;E interface, updating the control system accordingly.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45518942109869,"sku":"CV-OPCSAE","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/honeywell-cv-opcsae-event-server-cai-w1130tunyt2.jpg?v=1766982484","url":"https:\/\/www.maxwellplc.com\/products\/honeywell-cv-opcsae-event-server-cai-industrial-opc-alarm-event-data-server","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}